A 3-dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy:: Evaluation for 131I using Monte Carlo simulation

被引:0
作者
Ljungberg, M [1 ]
Sjögreen, K
Liu, XW
Frey, E
Dewaraja, Y
Strand, SE
机构
[1] Lund Univ, Jubilee Inst, Dept Radiat Phys, SE-22185 Lund, Sweden
[2] Zhongshan Univ, Dept Phys, Guangzhou, Peoples R China
[3] Univ N Carolina, Chapel Hill, NC USA
[4] Univ Michigan, Med Ctr, Ann Arbor, MI USA
关键词
Monte Carlo; absorbed dose; SPECT; I-131; image registration;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A general method is presented for patient-specific 3-dimensional absorbed dose calculations based on quantitative SPECT activity measurements. Methods: The computational scheme includes a method for registration of the CT image to the SPECT image and position-dependent compensation for attenuation, scatter, and collimator detector response performed as part of an iterative reconstruction method. A method for conversion of the measured activity distribution to a 3-dimensional absorbed dose distribution, based on the EGS4 (electron-gamma shower, version 4) Monte Carlo code, is also included. The accuracy of the activity quantification and the absorbed dose calculation is evaluated on the basis of realistic Monte Carlo-simulated SPECT data, using the SIMIND (simulation of imaging nuclear detectors) program and a voxel-based computer phantom. CT images are obtained from the computer phantom, and realistic patient movements are added relative to the SPECT image. The SPECT-based activity concentration and absorbed dose distributions are compared with the true ones. Results: Correction could be made for object scatter, photon attenuation, and scatter penetration in the collimator. However, inaccuracies were imposed by the limited spatial resolution of the SPECT system, for which the collimator response correction did not fully compensate. Conclusion: The presented method includes compensation for most parameters degrading the quantitative image information. The compensation methods are based on physical models and therefore are generally applicable to other radionuclides. The proposed evaluation methodology may be used as a basis for future intercomparison of different methods.
引用
收藏
页码:1101 / 1109
页数:9
相关论文
共 27 条
  • [1] Bolch WE, 1999, J NUCL MED, V40, p11S
  • [2] DEVELOPMENT AND VALIDATION OF A MONTE-CARLO SIMULATION OF PHOTON TRANSPORT IN AN ANGER CAMERA
    DEVRIES, DJ
    MOORE, SC
    ZIMMERMAN, RE
    MUELLER, SP
    FRIEDLAND, B
    LANZA, RC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) : 430 - 438
  • [3] A parallel Monte Carlo code for planar and SPECT imaging:: implementation, verification and applications in 131I SPECT
    Dewaraja, YK
    Ljungberg, M
    Majumdar, A
    Bose, A
    Koral, KF
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2002, 67 (02) : 115 - 124
  • [4] Dewaraja YK, 2000, J NUCL MED, V41, P123
  • [5] Monte Carlo evaluation of object shape effects in iodine-1 31 SPET tumor activity quantification
    Dewaraja, YK
    Ljungberg, M
    Koral, KF
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (07) : 900 - 906
  • [6] Duck F. A., 1990, PHYS PROPERTIES TISS, P137, DOI DOI 10.1016/B978-0-12-222800-1.50009-7
  • [7] Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy
    Erdi, AK
    Yorke, ED
    Loew, MH
    Erdi, YE
    Sarfaraz, M
    Wessels, BW
    [J]. MEDICAL PHYSICS, 1998, 25 (11) : 2226 - 2233
  • [8] A FAST PROJECTOR-BACKPROJECTOR PAIR MODELING THE ASYMMETRIC, SPATIALLY VARYING SCATTER RESPONSE FUNCTION FOR SCATTER COMPENSATION IN SPECT IMAGING
    FREY, EC
    JU, ZW
    TSUI, BMW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1192 - 1197
  • [9] FREY EC, 1997, C REC IEEE MED IM C, V2, P1082
  • [10] A Monte Carlo approach to patient-specific dosimetry
    Furhang, EE
    Chui, CS
    Sgouros, G
    [J]. MEDICAL PHYSICS, 1996, 23 (09) : 1523 - 1529