Real-Time Quantitative PCR To Determine Chlamydial Load in Men and Women in a Community Setting

被引:26
|
作者
Wiggins, R. [2 ]
Graf, S. [3 ]
Low, N. [4 ]
Horner, P. J. [1 ]
机构
[1] Univ Bristol, Dept Social Med, Bristol BS8 2PS, Avon, England
[2] Dept Clin Sci S Bristol, Div Cellular & Mol Med, Bristol BS8 1TD, Avon, England
[3] Swiss Fed Off Publ Hlth, Bern, Switzerland
[4] Univ Bern, Inst Social & Prevent Med, Bern, Switzerland
关键词
INCLUSION-FORMING UNITS; TRACHOMATIS;
D O I
10.1128/JCM.00005-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We used a PCR method to quantify the loads of Chlamydia trachomatis organisms in self-collected urine and vulvovaginal swab (VVS) samples from 93 women and 30 men participating in the Chlamydia Screening Studies Project, a community-based study of individuals not seeking health care. For women, self-collected VVS had a higher mean chlamydial load (10,405 organisms/ml; 95% confidence interval [ 95% CI], 5,167 to 21,163 organisms/ml) than did first-void urines (FVU) (503 organisms/ml; 95% CI, 250 to 1,022 organisms/ml; P < 0.001). Chlamydial loads in female and male self-collected FVU specimens were similar (P = 0.634). The mean chlamydial load in FVU specimens decreased with increasing age in females and males. There was no strong statistical evidence of differences in chlamydial load in repeat male and female FVU specimens taken when patients attended for treatment a median of 23.5 (range, 14 to 62) and 28 (range, 13 to 132) days later, respectively, or in VVS taken a median of 35 (range, 14 to 217) days later. In this study, chlamydial load values for infected persons in the community who were not seeking treatment were lower than those published in other studies involving symptomatic patients attending clinical settings. This might have implications for estimates of the infectiousness of chlamydia. The results of this study provide a scientific rationale for preferring VVS to FVU specimens from women.
引用
收藏
页码:1824 / 1829
页数:6
相关论文
共 50 条
  • [1] The assessment of chlamydial load in urine and vulvo-vaginal swabs in a community setting using quantitative real-time PCR
    Wiggins, R
    Horner, PJ
    Low, N
    SEXUALLY TRANSMITTED INFECTIONS, 2006, 82 : A3 - A3
  • [2] The assessment of chlamydial load in urine and vulvo-vaginal swabs in a community setting using quantitative real-time PCR, and comparison with results from enzyme linked immunoassays
    Wiggins, R
    Low, N
    Horner, PJ
    SEXUALLY TRANSMITTED INFECTIONS, 2006, 82 : A11 - A11
  • [3] Real-time quantitative PCR
    Schmittgen, TD
    METHODS, 2001, 25 (04) : 383 - 385
  • [4] Quantitative analysis of cytomegalovirus load using a real-time PCR assay
    Tanaka, N
    Kimura, H
    Iida, K
    Saito, Y
    Tsuge, I
    Yoshimi, A
    Matsuyama, T
    Morishima, T
    JOURNAL OF MEDICAL VIROLOGY, 2000, 60 (04) : 455 - 462
  • [5] Validation of a quantitative real-time PCR assay for CMV viral load
    Thorne, LB
    Civalier, C
    Fan, HX
    Gulley, ML
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2004, 6 (04): : 422 - 422
  • [6] Using quantitative real-time PCR to determine the hygienic status of cattle manure
    Lebuhn, M
    Effenberger, M
    Gronauer, A
    Wilderer, PA
    Wuertz, S
    WATER SCIENCE AND TECHNOLOGY, 2003, 48 (04) : 97 - 103
  • [7] Real-time quantitative PCR in parasitology
    Bell, AS
    Ranford-Cartwright, LC
    TRENDS IN PARASITOLOGY, 2002, 18 (08) : 337 - 342
  • [8] Comparison of two real-time quantitative PCR methods for the determination of adenovirus load
    Saglik, Ymran
    Mutlu, Derya
    Sarinoglu, Rabia Can
    Ongut, Gozde
    Bozkurt, Selen
    Colak, Dilek
    JOURNAL OF CLINICAL VIROLOGY, 2015, 70 : S72 - S72
  • [9] Evaluation of uncertainty in quantitative real-time PCR
    Love, John L.
    Scholes, Paula
    Gilpin, Brent
    Savill, Marion
    Lin, Susan
    Samuel, Laly
    JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 67 (02) : 349 - 356
  • [10] Gene dosage by quantitative real-time PCR
    Boulay, JL
    Reuter, J
    Ritschard, R
    Terracciano, L
    Herrmann, R
    Rochlitz, C
    BIOTECHNIQUES, 1999, 27 (02) : 228 - +