Correlations Between Branch Vessel Catheterization and Procedural Complexity in Fenestrated and Branched Endovascular Aneurysm Repair

被引:7
|
作者
Budtz-Lilly, Jacob [1 ,2 ]
Liungman, Krister [2 ]
Wanhainen, Anders [2 ]
Mani, Kevin [2 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiothorac & Vasc Surg, DK-8200 Aarhus N, Denmark
[2] Uppsala Univ, Dept Surg Sci, Vasc Surg Sect, Uppsala, Sweden
关键词
endovascular aneurysm repair; FEVAR; BEVAR; catheterization; radiation exposure; abdominal aortic aneurysm; JUXTARENAL AORTIC-ANEURYSM; RADIATION-EXPOSURE; EDITORS CHOICE; STENT-GRAFTS; OUTCOMES;
D O I
10.1177/1538574418823594
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: The use of fenestrated and branched endovascular technologies in complex aortic aneurysm repair (F/BEVAR) is increasing, with a trend toward using longer sealing zones and incorporating more target vessels. Successful aneurysm exclusion and prevention of long-term treatment failure need to be balanced against the increased complexity of more extensive procedures. The aim of this study was to analyze relationships between the number of catheterized vessels and multiple operative variables as a means for evaluating procedural complexity. Methods: Operative data from consecutive F/BEVAR procedures performed at a single center from 2012 to 2015 were analyzed. An equal number of EVAR procedures, randomly selected, from this period were also analyzed. Only intact aneurysms were included. Complex aneurysms were grouped based on the required number of target vessel catheterization. Ten procedural variables, categorized as perioperative, postoperative, and radiologic-related, were compared. Pearson correlation analysis and regression analysis were performed. The correlation coefficients, r, were classified using Cohen boundaries, r >= 0.5 indicating a strong relationship. Results: There were 63 EVAR, 40 FEVAR, and 22 BEVAR procedures. There was no significant difference in patient comorbidities between conventional EVAR and complex procedure groups. The complex procedures included 23 two-vessel, 20 three-vessel, and 19 four-vessel catheterizations. Strong linear relationships between the number of branch vessel catheterizations and the following variables were identified: accumulated skin dose (r = .504), contrast volume (r = .652), fluoroscopy duration (r = .598), number of angiography series (r = .650), anesthesiology duration (r = .742), procedure duration (r = .554), and total length of stay (r = .533). Conclusion: The complexity of FEVAR and BEVAR procedures reveals strong correlations between multiple peri- and postoperative variables. These exposures and risks should be borne in mind when considering treatment of complex abdominal aortic aneurysms as well as long-term clinical outcomes.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [31] Mid-term results of endovascular aneurysm repair with branched and fenestrated endografts
    Muhs, Bart E.
    Verhoeven, Eric L. G.
    Zeebregts, Clark J.
    Tielliu, Ignace F. J.
    Prins, Ted R.
    Verhagen, Hence J. M.
    van den Dungen, Jan J. A. M.
    JOURNAL OF VASCULAR SURGERY, 2006, 44 (01) : 9 - 15
  • [32] Fenestrated-Branched Endovascular Thoracoabdominal Aortic Aneurysm Repair for Chronic Dissections
    Baker, Aaron C.
    Oderich, Gustavo S.
    Hofer, Jan
    Ribeiro, Mauricio
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 231S - 231S
  • [33] Fenestrated and branched endovascular aneurysm repair outcomes for type II and III thoracoabdominal aortic aneurysm
    Tanious, Adam
    Lella, Srihari
    Adams, Ann S.
    Eagleton, Matthew J.
    ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 25 (04): : 332 - 338
  • [34] Sequential Catheterization and Progressive Deployment of the Zenith® t-Branch™ Device for Branched Endovascular Aortic Aneurysm Repair
    Fatemeh Malekpour
    Carla K. Scott
    Melissa L. Kirkwood
    Carlos H. Timaran
    CardioVascular and Interventional Radiology, 2021, 44 : 156 - 160
  • [35] Sequential Catheterization and Progressive Deployment of the Zenith® t-Branch™ Device for Branched Endovascular Aortic Aneurysm Repair
    Malekpour, Fatemeh
    Scott, Carla K.
    Kirkwood, Melissa L.
    Timaran, Carlos H.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (01) : 156 - 160
  • [36] Postdissection aortic aneurysm sac enlargement after fenestrated and branched endovascular aortic aneurysm repair
    Figueroa, Andres V.
    Tanenbaum, Mira T.
    Timaran, Carlos H.
    Oderich, Gustavo S.
    Eagleton, Matthew J.
    Schanzer, Andres
    Farber, Mark A.
    Beck, Adam W.
    Schneider, Darren B.
    Gasper, Warren
    Sweet, Matthew P.
    Lee, Anthony
    Cantor, Ryan S.
    Li, Xingsheng
    JOURNAL OF VASCULAR SURGERY, 2024, 80 (03)
  • [37] Indications for fenestrated endovascular aneurysm repair
    Cross, J.
    Raine, R.
    Harris, P.
    Richards, T.
    BRITISH JOURNAL OF SURGERY, 2012, 99 (02) : 217 - 224
  • [38] Increasing Aortic Coverage Improves Branch Stability in Fenestrated Endovascular Aneurysm Repair
    Witheford, Miranda
    Au, Darica
    Mastracci, Tara M.
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (05) : E423 - E423
  • [39] Evolution of fenestrated/branched endovascular aortic aneurysm repair complexity and outcomes at an organized center for the treatment of complex aortic disease
    Simons, Jessica P.
    Crawford, Allison S.
    Flanagan, Colleen P.
    Aiello, Francesco A.
    Arous, Edward J.
    Judelson, Dejah R.
    Messina, Louis M.
    Robichaud, Devon, I
    Valliere, Shauneen A.
    Schanzer, Andres
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (04) : 1148 - +
  • [40] The "Double Snare" Technique for Branch Catheterization in Endovascular Thoracoabdominal Aneurysm Repair
    Antonello, Michele
    Dall'Antonia, Alberto
    Piazza, Michele
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (05) : 776 - 779