Correlations Between Branch Vessel Catheterization and Procedural Complexity in Fenestrated and Branched Endovascular Aneurysm Repair

被引:7
作者
Budtz-Lilly, Jacob [1 ,2 ]
Liungman, Krister [2 ]
Wanhainen, Anders [2 ]
Mani, Kevin [2 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiothorac & Vasc Surg, DK-8200 Aarhus N, Denmark
[2] Uppsala Univ, Dept Surg Sci, Vasc Surg Sect, Uppsala, Sweden
关键词
endovascular aneurysm repair; FEVAR; BEVAR; catheterization; radiation exposure; abdominal aortic aneurysm; JUXTARENAL AORTIC-ANEURYSM; RADIATION-EXPOSURE; EDITORS CHOICE; STENT-GRAFTS; OUTCOMES;
D O I
10.1177/1538574418823594
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: The use of fenestrated and branched endovascular technologies in complex aortic aneurysm repair (F/BEVAR) is increasing, with a trend toward using longer sealing zones and incorporating more target vessels. Successful aneurysm exclusion and prevention of long-term treatment failure need to be balanced against the increased complexity of more extensive procedures. The aim of this study was to analyze relationships between the number of catheterized vessels and multiple operative variables as a means for evaluating procedural complexity. Methods: Operative data from consecutive F/BEVAR procedures performed at a single center from 2012 to 2015 were analyzed. An equal number of EVAR procedures, randomly selected, from this period were also analyzed. Only intact aneurysms were included. Complex aneurysms were grouped based on the required number of target vessel catheterization. Ten procedural variables, categorized as perioperative, postoperative, and radiologic-related, were compared. Pearson correlation analysis and regression analysis were performed. The correlation coefficients, r, were classified using Cohen boundaries, r >= 0.5 indicating a strong relationship. Results: There were 63 EVAR, 40 FEVAR, and 22 BEVAR procedures. There was no significant difference in patient comorbidities between conventional EVAR and complex procedure groups. The complex procedures included 23 two-vessel, 20 three-vessel, and 19 four-vessel catheterizations. Strong linear relationships between the number of branch vessel catheterizations and the following variables were identified: accumulated skin dose (r = .504), contrast volume (r = .652), fluoroscopy duration (r = .598), number of angiography series (r = .650), anesthesiology duration (r = .742), procedure duration (r = .554), and total length of stay (r = .533). Conclusion: The complexity of FEVAR and BEVAR procedures reveals strong correlations between multiple peri- and postoperative variables. These exposures and risks should be borne in mind when considering treatment of complex abdominal aortic aneurysms as well as long-term clinical outcomes.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 29 条
  • [11] Radiation-Induced DNA Damage in Operators Performing Endovascular Aortic Repair
    El-Sayed, Tamer
    Patel, Ashish S.
    Cho, Jun S.
    Kelly, James A.
    Ludwinski, Francesca E.
    Saha, Prakash
    Lyons, Oliver T.
    Smith, Alberto
    Modarai, Bijan
    [J]. CIRCULATION, 2017, 136 (25) : 2406 - +
  • [12] Reporting standards for thoracic endovascular aortic repair (TEVAR)
    Fillinger, Mark F.
    Greenberg, Roy K.
    McKinsey, James F.
    Chaikof, Elliot L.
    [J]. JOURNAL OF VASCULAR SURGERY, 2010, 52 (04) : 1022 - 1033
  • [13] The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair
    Fossaceca, Rita
    Brambilla, Marco
    Guzzardi, Giuseppe
    Cerini, Paolo
    Renghi, Alessandra
    Valzano, Serena
    Brustia, Piero
    Carriero, Alessandro
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (11) : 2424 - 2431
  • [14] Contemporary analysis of descending thoracic and thoracoabdominal aneurysm repair - A comparison of endovascular and open techniques
    Greenberg, Roy K.
    Lu, Qingsheng
    Roselli, Eric E.
    Svensson, Lars G.
    Moon, Michael C.
    Hernandez, Adrian V.
    Dowdall, Joseph
    Cury, Marcelo
    Francis, Catherine
    Pfaff, Kathryn
    Clair, Daniel G.
    Ouriel, Kenneth
    Lytle, Bruce W.
    [J]. CIRCULATION, 2008, 118 (08) : 808 - 817
  • [15] Editor's Choice - Minimizing Radiation Exposure During Endovascular Procedures: Basic Knowledge, Literature Review, and Reporting Standards
    Hertault, A.
    Maurel, B.
    Midulla, M.
    Bordier, C.
    Desponds, L.
    Kilani, M. Saeed
    Sobocinski, J.
    Haulon, S.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (01) : 21 - 36
  • [16] Impact of Hybrid Rooms with Image Fusion on Radiation Exposure during Endovascular Aortic Repair
    Hertault, A.
    Maurel, B.
    Sobocinski, J.
    Gonzalez, T. Martin
    Le Roux, M.
    Azzaoui, R.
    Midulla, M.
    Haulon, S.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (04) : 382 - 390
  • [17] Risk of Radiation Exposure during Endovascular Aortic Repair
    Howells, P.
    Eaton, R.
    Patel, A. S.
    Taylor, P.
    Modarai, B.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (04) : 393 - 397
  • [18] Radiation burden of patients undergoing endovascular abdominal aortic aneurysm repair
    Kalef-Ezra, John A.
    Karavasilis, Stratos
    Ziogas, Dimosthenis
    Dristiliaris, Dimitris
    Michalis, Lampros K.
    Matsagas, Miltiadis
    [J]. JOURNAL OF VASCULAR SURGERY, 2009, 49 (02) : 283 - 287
  • [19] Comparison of outcomes for double fenestrated endovascular aneurysm repair versus triple or quadruple fenestrated endovascular aneurysm repair in the treatment of complex abdominal aortic aneurysms
    Katsargyris, Athanasios
    Oikonomou, Kyriakos
    Kouvelos, George
    Mufty, Hozan
    Ritter, Wolfgang
    Verhoeven, Eric L. G.
    [J]. JOURNAL OF VASCULAR SURGERY, 2017, 66 (01) : 29 - 36
  • [20] Surgeon radiation dose during complex endovascular procedures
    Kirkwood, Melissa L.
    Guild, Jeffrey B.
    Arbique, Gary M.
    Anderson, Jon A.
    Valentine, R. James
    Timaran, Carlos