Characterization of a Partially Covered AM-MPT and Its Application to Damage Scans of Small Diameter Pipes Based on Analysis of the Beam Directivity of the MHz Lamb Wave

被引:3
作者
Fang, Zhou [1 ]
Tse, Peter W. [1 ]
Fan, Xu [1 ]
机构
[1] City Univ Hong Kong, Dept Syst Engn & Engn Management, Hong Kong, Peoples R China
关键词
Magnetic fields; Magnetostriction; Transducers; Analytical models; Acoustics; Frequency control; Magnetic analysis; Defect characterization; frequency control; transducers; wave propagation; TRANSVERSE DEMAGNETIZING FACTORS; AXISYMMETRICAL GUIDED-WAVES; LONG RECTANGULAR BARS; COIL EMATS; PATCH; TRANSDUCTION; PROPAGATION; INSPECTION;
D O I
10.1109/TUFFC.2020.3011476
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To perform a complete scan of a small diameter pipe is difficult for two reasons. First, the beam directivity of the Lamb wave within a small diameter pipe is worse than that within a large diameter pipe. Second, the circumferential range of the small diameter pipe is so limited that it can allow less transducer to be attached on its surface. That means the signals from various circumferential positions are difficult to obtain. This article reports a method that can scan damage within a small diameter pipe using a partially covered axially magnetized magnetostrictive patch transducer (AM-MPT) around the circumference of a pipe based on the analysis of the beam directivity of the MHz Lamb wave. The partially covered AM-MPT was moved around the circumference of a pipe for subsequent measurements to get signals from various circumferential positions. To trigger strong enough MHz Lamb wave, the circumferential coverage of the partially covered AM-MPT was not less than half of the circumference of the pipe, and the greater length-to-width ratio of the magnetostrictive patch was used. The analytical model of beam directivity of the Lamb wave was used to study the Lamb wave propagation in the rolled plate. Then the analytical model was modulated to evaluate the damage scan within a small diameter pipe. The experimental results supported the analytical model through different circumferential coverages of the transducer, and different sizes and axial positions of the damage. The proposed method was proven to have the potential to be applied to damage scans within a small diameter pipe.
引用
收藏
页码:2717 / 2730
页数:14
相关论文
共 36 条
[1]  
Brath AJ, 2014, IEEE T ULTRASON FERR, V61, P815, DOI [10.1109/TUFFC.2014.6805695, 10.1109/TUFFC.2014.2973]
[2]   Demagnetizing factors for rectangular prisms [J].
Chen, DX ;
Pardo, E ;
Sanchez, A .
IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (06) :2077-2088
[3]   Transverse demagnetizing factors of long rectangular bars: I. Analytical expressions for extreme values of susceptibility [J].
Chen, DX ;
Prados, C ;
Pardo, E ;
Sanchez, A ;
Hernando, A .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (08) :5254-5259
[4]   Demagnetizing factors of rectangular prisms and ellipsoids [J].
Chen, DX ;
Pardo, E ;
Sanchez, A .
IEEE TRANSACTIONS ON MAGNETICS, 2002, 38 (04) :1742-1752
[5]   Megahertz-Range Guided Pure Torsional Wave Transduction and Experiments Using a Magnetostrictive Transducer [J].
Cho, Seung Hyun ;
Kim, Hoe Woong ;
Kim, Yoon Young .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (05) :1225-1229
[6]   Interaction Between SH0 Guided Waves and Tilted Surface-Breaking Cracks in Plates [J].
Combaniere, Jerome ;
Cawley, Peter ;
McAughey, Kevin ;
Giese, Jochen .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (01) :119-128
[7]   The Application of Synthetic Focusing for Imaging Crack-Like Defects in Pipelines Using Guided Waves [J].
Davies, Jacob ;
Cawley, Peter .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) :759-771
[8]   A multi-helical ultrasonic imaging approach for the structural health monitoring of cylindrical structures [J].
Dehghan-Niri, Ehsan ;
Salamone, Salvatore .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2015, 14 (01) :73-85
[9]   Demagnetization-based axial magnetized magnetostrictive patch transducers for locating defect in small-diameter pipes using the non-axisymmetric guided wave [J].
Fang, Zhou ;
Tse, Peter W. .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2019, 18 (5-6) :1738-1760
[10]   Axial magnetized patch for efficient transduction of longitudinal guided wave and defect identification in concrete-covered pipe risers [J].
Fang, Zhou ;
Tse, Peter W. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (10)