CFD investigation on the effects of wind and thermal wall-flow on pollutant transmission in a high-rise building

被引:41
作者
Mu, Di [1 ]
Gao, Naiping [1 ]
Zhu, Tong [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai, Peoples R China
关键词
Wind effect; Thermal plume; High-rise building; Pollutant transmission; Simulation; FINE PARTICULATE MATTER; LARGE-EDDY SIMULATION; RESIDENTIAL BUILDINGS; AIRBORNE TRANSMISSION; NATURAL VENTILATION; AIR-FLOW; INTERUNIT DISPERSION; NUMERICAL-SIMULATION; AEROSOL TRANSMISSION; BUILT ENVIRONMENT;
D O I
10.1016/j.buildenv.2018.03.051
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The solar radiation can heat the building outer surface, and then cause the upward natural convection flows adjacent to the wall. This phenomenon is especially obvious on a windless sunny day. The near wall thermal plume can drive gaseous pollutants released from lower floors to upper floors. Combined with the effect of ambient approaching wind, the transmission routes will be very complicated. The paper aims to investigate the airflow patterns and pollutant transmission within a building under the effects of wind and thermal forces. A hypothetical twenty-storey slab-shape high-rise building in Shanghai with single-sided natural ventilation is set as the research object in the present study. The intensity of solar radiation on a typical day during transition season is theoretically analysed. The temperature difference between the heated building envelope and the ambient air is calculated by a simplified heat balance model. Finally, the tracer gas method is employed in the numerical simulation to analyse the influence of the wind and wall thermal plume flow on the inter-flat pollutant transmission characteristics. The results show that, the temperature difference between sunward and shady side wall is about 10 K at noon on the designate day. When the source is set as a point with steady intensity and the buoyancy is stronger than or approximately equivalent to the wind, the reentry ratio of the flat immediately above the source can be around 25%.
引用
收藏
页码:185 / 197
页数:13
相关论文
共 62 条
  • [11] Ventilation performance prediction for buildings: A method overview and recent applications
    Chen, Qingyan
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (04) : 848 - 858
  • [12] Influence of regional pollution outflow on the concentrations of fine particulate matter and visibility in the coastal area of southern China
    Cheung, HC
    Wang, T
    Baumann, K
    Guo, H
    [J]. ATMOSPHERIC ENVIRONMENT, 2005, 39 (34) : 6463 - 6474
  • [13] Wind and buoyancy driven natural ventilation in double skin facades
    Dama, Alessandro
    Angeli, Diego
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2016, 15 (3-4) : 288 - 301
  • [14] Natural convection flows along a 16-storey high-rise building
    Fan, Yifan
    Li, Yuguo
    Hang, Jian
    Wang, Kai
    Yang, Xinyan
    [J]. BUILDING AND ENVIRONMENT, 2016, 107 : 215 - 225
  • [15] Franke J., 2007, COST Action 732, Quality Assurance and Improvement of Microscale Meteorological Models
  • [16] The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation
    Gao, N. P.
    Niu, J. L.
    Perino, M.
    Heiselberg, P.
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (11) : 1805 - 1817
  • [17] The airborne transmission of infection between flats in high-rise residential buildings: Particle simulation
    Gao, N. P.
    Niu, J. L.
    Perino, M.
    Heiselberg, P.
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (02) : 402 - 410
  • [18] Experimental investigation of air flow and temperature distribution in deep urban canyons for natural ventilation purposes
    Georgakis, C
    Santamouris, A
    [J]. ENERGY AND BUILDINGS, 2006, 38 (04) : 367 - 376
  • [19] Functional Impairment in the Diagnosis of Mild Cognitive Impairment
    Han, Ji Won
    Lee, Seok Bum
    Kim, Tae Hui
    Park, Joon Hyuk
    Lee, Jung Jae
    Huh, Yoon Seok
    Choi, Eun Ae
    Choe, Jin Yeong
    Do, Yeon Ja
    Lee, Dong Young
    Kim, Ki Woong
    [J]. ALZHEIMER DISEASE & ASSOCIATED DISORDERS, 2011, 25 (03) : 225 - 229
  • [20] Positive-pressure isolation and the prevention of invasive aspergillosis. What is the evidence?
    Humphreys, H