CFD investigation on the effects of wind and thermal wall-flow on pollutant transmission in a high-rise building

被引:41
作者
Mu, Di [1 ]
Gao, Naiping [1 ]
Zhu, Tong [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai, Peoples R China
关键词
Wind effect; Thermal plume; High-rise building; Pollutant transmission; Simulation; FINE PARTICULATE MATTER; LARGE-EDDY SIMULATION; RESIDENTIAL BUILDINGS; AIRBORNE TRANSMISSION; NATURAL VENTILATION; AIR-FLOW; INTERUNIT DISPERSION; NUMERICAL-SIMULATION; AEROSOL TRANSMISSION; BUILT ENVIRONMENT;
D O I
10.1016/j.buildenv.2018.03.051
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The solar radiation can heat the building outer surface, and then cause the upward natural convection flows adjacent to the wall. This phenomenon is especially obvious on a windless sunny day. The near wall thermal plume can drive gaseous pollutants released from lower floors to upper floors. Combined with the effect of ambient approaching wind, the transmission routes will be very complicated. The paper aims to investigate the airflow patterns and pollutant transmission within a building under the effects of wind and thermal forces. A hypothetical twenty-storey slab-shape high-rise building in Shanghai with single-sided natural ventilation is set as the research object in the present study. The intensity of solar radiation on a typical day during transition season is theoretically analysed. The temperature difference between the heated building envelope and the ambient air is calculated by a simplified heat balance model. Finally, the tracer gas method is employed in the numerical simulation to analyse the influence of the wind and wall thermal plume flow on the inter-flat pollutant transmission characteristics. The results show that, the temperature difference between sunward and shady side wall is about 10 K at noon on the designate day. When the source is set as a point with steady intensity and the buoyancy is stronger than or approximately equivalent to the wind, the reentry ratio of the flat immediately above the source can be around 25%.
引用
收藏
页码:185 / 197
页数:13
相关论文
共 62 条
  • [1] Large eddy simulation of wind-induced interunit dispersion around multistory buildings
    Ai, Z. T.
    Mak, C. M.
    [J]. INDOOR AIR, 2016, 26 (02) : 259 - 273
  • [2] A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions
    Ai, Z. T.
    Mak, C. M.
    [J]. ATMOSPHERIC ENVIRONMENT, 2014, 88 : 1 - 13
  • [3] Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings
    Ai, Z. T.
    Mak, C. M.
    Niu, J. L.
    [J]. INDOOR AIR, 2013, 23 (05) : 417 - 429
  • [4] [Anonymous], 2015, ASHRAE HDB
  • [5] [Anonymous], 2009, ASHRAE HDB
  • [6] ASHRAE Task Group, 1975, PROC DET HEAT COOL L, P76
  • [7] Flow visualization, PIV measurement and CFD calculation for fluid-driven natural cross-ventilation in a scale model
    Bangalee, M. Z. I.
    Miau, J. J.
    Lin, S. Y.
    Yang, J. H.
    [J]. ENERGY AND BUILDINGS, 2013, 66 : 306 - 314
  • [8] Spread and prevention of some common viral infections in community facilities and domestic homes
    Barker, J
    Stevens, D
    Bloomfield, SF
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2001, 91 (01) : 7 - 21
  • [9] Experiments on turbulent natural convection in an enclosed tall cavity
    Betts, PL
    Bokhari, IH
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2000, 21 (06) : 675 - 683
  • [10] Flow and dispersion in urban areas
    Britter, RE
    Hanna, SR
    [J]. ANNUAL REVIEW OF FLUID MECHANICS, 2003, 35 : 469 - 496