Comparison of neointimal coverage between durable-polymer everolimus-eluting stents and bioresorbable-polymer everolimus-eluting stents 1 year after implantation using high-resolution coronary angioscopy

被引:6
作者
Nojima, Yuhei [1 ]
Adachi, Hidenori [1 ]
Ihara, Madoka [1 ]
Kurimoto, Tetsuya [1 ]
Okayama, Keita [2 ]
Sakata, Yasushi [2 ]
Nanto, Shinsuke [1 ]
机构
[1] Nishinomiya Municipal Cent Hosp, Dept Cardiol, Nishinomiya, Hyogo, Japan
[2] Osaka Univ, Dept Cardiovasc Med, Grad Sch Med, Suita, Osaka, Japan
关键词
arterial healing; drug-eluting stent; imaging; neointima formation; BARE-METAL STENTS; THROMBOSIS; EFFICACY; OUTCOMES; SAFETY; PLAQUE;
D O I
10.1002/ccd.28095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We aimed to compare the coronary angioscopic appearance of neointimal coverage (NIC) over durable-polymer everolimus-eluting stents (XIENCE-EES) and bioresorbable-polymer everolimus-eluting stents (SYNERGY-EES) 1 year after implantation. Background XIENCE-EES and SYNERGY-EES have been developed to prevent delayed arterial healing associated with first generation drug-eluting stents. However, the process of arterial healing after XIENCE-EES and SYNERGY-EES implantation has not been clarified. Methods Patients who underwent implantation of XIENCE-EES (n = 20) or SYNERGY-EES (n = 20) were enrolled in this study. Coronary angiography and coronary angioscopy were performed 12 +/- 1 months after stent implantation. The NIC over the stent was classified into four grades: grade 0, stent struts fully exposed; grade 1, stent struts bulging into the lumen and, still visible; grade 2, stent struts embedded in neointima but still visible; and grade 3, stent struts fully embedded and invisible. Stents exhibiting more than one NIC grade was defined as heterogeneous. Moreover, presence of thrombi was investigated. Results The distribution of dominant NIC grade (XIENCE-EES: grade 0, 0%; grade 1, 25%; grade 2, 50%; grade 3, 25%; SYNERGY-EES: grade 0, 0%; grade 1, 5%; grade 2, 15%; grade 3, 80%; P = 0.002) and NIC heterogeneity was significantly different (P = 0.004). Thrombi were more frequent in XIENCE-EES than in SYNERGY-EES (40 versus 10%, respectively; P = 0.03). Conclusion Compared with XIENCE-EES, SYNERGY-EES were well covered by neointima and accompanied by fewer thrombi. These findings implied arterial healing of SYNERGY-EES was better than that of XIENCE-EES.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 26 条
[1]   Heterogeneous Arterial Healing in Patients Following Paclitaxel-Eluting Stent Implantation Comparison With Sirolimus-Eluting Stents [J].
Awata, Masaki ;
Nanto, Shinsuke ;
Uematsu, Masaaki ;
Morozumi, Takakazu ;
Watanabe, Tetsuya ;
Onishi, Toshinari ;
Iida, Osamu ;
Sera, Fusako ;
Minamiguchi, Hitoshi ;
Kotani, Jun-ichi ;
Nagata, Seiki .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :453-458
[2]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[3]   Comparison of Chronic Angioscopic Findings of Bare Metal Stents, 1st-Generation Drug-Eluting Stents and 2nd-Generation Drug-Eluting Stents - Multicenter Study of Intra-Coronary Angioscopy After Stent (MICASA) [J].
Dai, Kazuoki ;
Matsuoka, Hiroshi ;
Kawakami, Hideo ;
Sato, Tetsuya ;
Watanabe, Kouki ;
Nakama, Yasuharu ;
Ishihara, Masaharu .
CIRCULATION JOURNAL, 2016, 80 (09) :1916-+
[4]   Coronary angioscopic findings 9 months after everolimus-eluting stent implantation compared with sirolimus-eluting stents [J].
Dai, Kazuoki ;
Ishihara, Masaharu ;
Inoue, Ichiro ;
Kawagoe, Takuji ;
Shimatani, Yuji ;
Miura, Fumiharu ;
Nakama, Yasuharu ;
Otani, Takayuki ;
Ooi, Kuniomi ;
Ikenaga, Hiroki ;
Nakamura, Masayuki ;
Miki, Takashi ;
Kishimoto, Shinji ;
Sumimoto, Yoji .
JOURNAL OF CARDIOLOGY, 2013, 61 (1-2) :22-30
[5]   Meta-Analysis of Everolimus-Eluting Versus Paclitaxel-Eluting Stents in Coronary Artery Disease [J].
Dangas, George D. ;
Serruys, Patrick W. ;
Kereiakes, Dean J. ;
Hermiller, James ;
Rizvi, Ali ;
Newman, William ;
Sudhir, Krishnankutty ;
Smith, Robert S., Jr. ;
Cao, Sherry ;
Theodoropoulos, Kleanthis ;
Cutlip, Donald E. ;
Lansky, Alexandra J. ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (09) :914-922
[6]  
DENHEIJER P, 1994, EUR HEART J, V15, P815
[7]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[8]   Comparison of early-phase arterial repair following cobalt-chrome everolimus-eluting stent and slow-release zotarolimus-eluting stent: an angioscopic study [J].
Ishihara T. ;
Iida O. ;
Fujita M. ;
Masuda M. ;
Okamoto S. ;
Nanto K. ;
Kanda T. ;
Tsujimura T. ;
Sunaga A. ;
Awata M. ;
Nanto S. ;
Uematsu M. .
Cardiovascular Intervention and Therapeutics, 2018, 33 (2) :163-168
[9]   Safety and Efficacy of Everolimus-Versus Sirolimus-Eluting Stents 5-Year Results From SORT OUT IV [J].
Jensen, Lisette Okkels ;
Thayssen, Per ;
Christiansen, Evald Hoj ;
Maeng, Michael ;
Ravkilde, Jan ;
Hansen, Knud Norregaard ;
Hansen, Henrik Steen ;
Krusell, Lars ;
Kaltoft, Anne ;
Tilsted, Hans Henrik ;
Berencsi, Klara ;
Junker, Anders ;
Lassen, Jens Flensted .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (07) :751-762
[10]   Investigation of the freely available easy-to-use software 'EZR' for medical statistics [J].
Kanda, Y. .
BONE MARROW TRANSPLANTATION, 2013, 48 (03) :452-458