Silyl-heparin bonding improves the patency and in vivo thromboresistance of carbon-coated polytetrafluoroethylene vascular grafts

被引:27
作者
Laredo, J
Xue, L
Husak, VA
Ellinger, J
Singh, G
Zamora, PO
Greisler, HP
机构
[1] Loyola Univ, Med Ctr, Dept Surg, Div Peripheral Vasc Surg, Maywood, IL 60153 USA
[2] Loyola Univ, Med Ctr, Dept Cell Biol Neurobiol & Anat, Maywood, IL 60153 USA
[3] Edward Hines Jr Vet Adm Hosp, Dept Surg, Hines, IL 60141 USA
[4] Biosurface Engn Technol, College Pk, MD USA
关键词
D O I
10.1016/j.jvs.2003.12.025
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives. Our purpose was to improve the performance of carbon-coated expanded polytetrafluoroethylene vascular grafts by bonding the grafts with silyl-heparin, a biologically active heparin analog, using polyethylene glycol as a cross-linking agent. Material and method: Silyl-heparin-bonded carbon-coated expanded polytetrafluoroethylene vascular grafts (Bard Peripheral Vascular, Tempe, Ariz), were evaluated for patency and platelet deposition 2 hours, 7 days, and 30 days after graft implantation in a canine bilateral aortoiliac artery model. Platelet deposition was determined by injection of autologous, (111)Indium-radiolabeled platelets, followed by a 2-hour circulation period prior to graft explantation. Histologic studies were performed on a 2-mm longitudinal strip of each graft (7-day and 30-day groups). Heparin activity of the explanted silyl-heparin grafts was determined by using an antithrombin-III based thrombin binding assay. Results. Overall chronic graft patency (7-day and 30-day groups) was 100% for the silyl-heparin bonded (16/16) grafts versus 68.75% for control (11/16) grafts (P = .043). Acute 2-hour graft patency was 100% for the silyl-heparin bonded (6/6) grafts versus 83.3% for control (5/6) grafts. Radiolabeled platelet deposition studies revealed a significantly lower amount of platelets deposited on the silyl-heparin grafts as compared with control grafts in the 30-day group (13.8 +/- 7.18 vs 28.4 +/- 9.73, CPM per cm2 per million platelets, mean +/- SD, P = .0451, Wilcoxon rank sum test). In the 2-hour group of dogs, a trend towards a lower deposition of platelets on the silyl-heparin grafts was observed. There was no significant difference in platelet deposition between the two grafts in the 7-day group. Histologic studies revealed a significant reduction in intraluminal graft thrombus present on the silyl-heparin grafts as compared with control grafts in the 30-day group of animals. In contrast, there was no difference in amount of graft thrombus present on both graft types in the 7-day group of dogs. Pre-implant heparin activity on the silyl-heparin bonded grafts was 2.0 IU/cm(2) (international units[IU]/cm(2)). Heparin activity remained present on the silyl-heparin grafts after explantation at all 3 time points (2 hours: above upper limit of assay, upper limit = 0.57, n = 6; 7 days: 0.106 +/- 0.015, n = 5; 30 days: 0.007 +/- 0.001, n = 5; mean +/- SD, IU/cm(2)). Conclusion: Silyl-heparin bonding onto carbon-coated expanded polytetrafluoroethylene vascular grafts resulted in (1) improved graft patency, (2) increased in vivo graft thromboresistance, and (3) a significant reduction in intraluminal graft thrombus. This graft may prove to be useful in the clinical setting.
引用
收藏
页码:1059 / 1065
页数:7
相关论文
共 24 条
  • [1] Surface heparinization of central venous catheters reduces microbial colonization in vitro and in vivo: Results from a prospective, randomized trial
    Appelgren, P
    RansjO, U
    Bindslev, L
    Espersen, F
    Larm, O
    [J]. CRITICAL CARE MEDICINE, 1996, 24 (09) : 1482 - 1489
  • [2] Improvements in GORE-TEX® Vascular Graft performance by Carmeda® BioActive Surface heparin immobilization
    Begovac, PC
    Thomson, RC
    Fisher, JL
    Hughson, A
    Gällhagen, A
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 25 (05) : 432 - 437
  • [3] Heparin-bonded Dacron or polytetrafluoroethylene for femoropopliteal bypass grafting: A multicenter trial
    Devine, C
    McCollum, C
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 33 (03) : 533 - 539
  • [4] Leukocyte activation and leukocyte procoagulant activities after blood contact with polystyrene and polyethylene glycol-immobilized polystyrene beads
    Gorbet, MB
    Sefton, MV
    [J]. JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2001, 137 (05): : 345 - 355
  • [5] IN-VIVO PLATELET DEPOSITION ON POLYTETRAFLUOROETHYLENE COATED WITH FIBRIN GLUE CONTAINING FIBROBLAST GROWTH-FACTOR-1 AND HEPARIN IN A CANINE MODEL
    GOSSELIN, C
    REN, DW
    ELLINGER, J
    GREISLER, HP
    [J]. AMERICAN JOURNAL OF SURGERY, 1995, 170 (02) : 126 - 130
  • [6] GROEGLER FM, 2001, MONT ANN S CURR CRIT
  • [7] Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children
    Hetzer, R
    Loebe, M
    Potapov, EV
    Weng, YG
    Stiller, B
    Hennig, E
    Alexi-Meskishvili, V
    Lange, PE
    [J]. ANNALS OF THORACIC SURGERY, 1998, 66 (05) : 1498 - 1505
  • [8] EFFECTS ON PROTEIN ADSORPTION, BACTERIAL ADHESION AND CONTACT-ANGLE OF GRAFTING PEG CHAINS TO POLYSTYRENE
    HOLMBERG, K
    BERGSTROM, K
    BRINK, C
    OSTERBERG, E
    TIBERG, F
    HARRIS, JM
    [J]. JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 1993, 7 (06) : 503 - 517
  • [9] SURFACE MODIFICATION FOR IMPROVED BLOOD COMPATIBILITY
    JACOBS, H
    GRAINGER, D
    OKANO, T
    KIM, SW
    [J]. ARTIFICIAL ORGANS, 1988, 12 (06) : 506 - 507
  • [10] Experience with heparin-bonded collagen-coated grafts for infrainguinal bypass
    Lambert, AW
    Fox, AD
    Williams, DJ
    Horrocks, M
    Budd, JS
    [J]. CARDIOVASCULAR SURGERY, 1999, 7 (05): : 491 - 494