Comparisons of Visual and Surgical Outcomes after Reuse or Replacement of Dislocated in-the-Bag Intraocular Lens

被引:8
作者
Baba, Takayuki [1 ]
Nizawa, Tomohiro [1 ]
Oshitari, Toshiyuki [1 ]
Yamamoto, Shuichi [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Chiba, Japan
基金
日本学术振兴会;
关键词
DISINSERTION;
D O I
10.1155/2018/7342917
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the visual and surgical outcomes after a reuse or a replacement of a dislocated in-the-bag intraocular lens (IOL). Methods. This was a retrospective, nonrandomized case series at a single ophthalmological institution. Cases with an in-the-bag dislocation of an IOL were treated by pars plana vitrectomy and the reuse or the replacement of the IOL. The lens was held by intrascleral fixation of the haptics of the IOL under both conditions. The same dislocated IOL was reused in 6 eyes (group A) or it was replaced with another IOL in the other 9 eyes (group B). The pre- and postoperative parameters analyzed included the visual acuity, refractive error, corneal endothelial cell density, and intraocular pressure (IOP). Results. There was no significant difference between the two groups in the postoperative visual acuity (P = 0.388), refractive error (P = 0.955), IOP (P = 0.529), and endothelial cell loss (P = 0.940). A breakage or a tilting of the IOL was observed and required replacement in three eyes in the reuse group (P = 0.044). Conclusions. Half of the cases with reused in-the-bag dislocated IOL had a breakage or a tilting of the IOL. The replacement of the in-the-bag dislocated IOL is better than the reuse of the IOL with intrascleral haptics fixation.
引用
收藏
页数:4
相关论文
共 11 条
[1]   Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules [J].
Agarwal, Amar ;
Kumar, Dhivya Ashok ;
Jacob, Soosan ;
Baid, Chandresh ;
Agarwal, Athiya ;
Srinivasan, Sridhar .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1433-1438
[2]   Late In-the-Bag Spontaneous Intraocular Lens Dislocation Evaluation of 86 Consecutive Cases [J].
Davis, Don ;
Brubaker, Jacob ;
Espandar, Ladan ;
Stringham, Jack ;
Crandall, Alan ;
Werner, Liliana ;
Mamalis, Nick .
OPHTHALMOLOGY, 2009, 116 (04) :664-670
[3]   Iris-claw intraocular lenses to correct aphakia in the absence of capsule support [J].
De Silva, Samantha R. ;
Arun, Kikkeri ;
Anandan, Maghizh ;
Glover, Nicholas ;
Patel, Chetan K. ;
Rosen, Paul .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09) :1667-1672
[4]   Spontaneous disinsertion of a haptic from a 3-piece acrylic foldable intraocular lens after surgery [J].
Fujishima, K ;
Yoshitomi, F ;
Oshika, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07) :1296-1298
[5]   Sutureless intrascleral posterior chamber intraocular lens fixation [J].
Gabor, Scharioth G. B. ;
Pavlidis, Mitrofanis M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1851-1854
[6]  
HYKIN P G, 1991, Eye (London), V5, P694
[7]   SURGICAL OUTCOME OF SIMULTANEOUS INTRAOCULAR LENS RESCUE AND SUTURELESS INTRASCLERAL TUNNEL FIXATION OF DISLOCATED INTRAOCULAR LENSES [J].
Kim, Min ;
Lee, Dong H. ;
Koh, Hyoung J. ;
Lee, Sung C. ;
Kim, Sung S. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (07) :1450-1457
[8]   Late In-the-Bag Intraocular Lens Dislocation A Randomized Clinical Trial Comparing Lens Repositioning and Lens Exchange [J].
Kristianslund, Olav ;
Raen, Marianne ;
Ostern, Atle E. ;
Drolsum, Liv .
OPHTHALMOLOGY, 2017, 124 (02) :151-159
[9]   Late spontaneous haptic disinsertion from a three-piece intraocular lens [J].
Solano, Joel M. ;
Baratz, Keith H. ;
Mahr, Michael A. ;
Erie, Jay C. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) :521-522
[10]  
TAYLOR DM, 1983, OPHTHALMOLOGY, V90, P19