Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation

被引:16
|
作者
Cauti, Filippo Maria [1 ]
Solimene, Francesco [2 ]
Stabile, Giuseppe [2 ]
Polselli, Marco [1 ]
Schillaci, Vincenzo [2 ]
Arestia, Alberto [2 ]
Shopova, Gergana [2 ]
Iaia, Luigi [2 ]
Giannitti, Carlo Maria [3 ]
Rossi, Pietro [1 ]
Bianchi, Stefano [1 ]
机构
[1] Fatebenefratelli Isola Tiberina, Osped San Giovanni Calib, Arrhythmol Unit, Via PonteQuattro Capi 39, I-00186 Rome, Italy
[2] Clin Montevergine, Arrhythmol Unit, Mercogliano, AV, Italy
[3] EPD Solut, Veenpluis 6, NL-5684 PC Best, Netherlands
来源
关键词
atrial fibrillation; cryoablation; new dielectric imaging system; occlusion tool; pulmonary vein isolation; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; TIME; TACHYARRHYTHMIAS; PREDICTOR;
D O I
10.1111/pace.14130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. Aim of the study The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). Methods We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX-EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new "occlusion tool" software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. Results A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 +/- 17 minutes. Mean fluoroscopy time was 6 +/- 2 minutes. No 30-day complications were observed. Conclusion The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [21] Cryoballoon ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kuehne, Michael
    Schaer, Beat
    Ammann, Peter
    Suter, Yves
    Osswald, Stefan
    Sticherling, Christian
    SWISS MEDICAL WEEKLY, 2010, 140 (15-16) : 214 - 221
  • [22] Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablation
    Sorgente, Antonio
    Chierchia, Gian Battista
    de Asmundis, Carlo
    Sarkozy, Andrea
    Namdar, Mehdi
    Capulzini, Lucio
    Yazaki, Yoshinao
    Mueller-Burri, Stephan-Andreas
    Bayrak, Fatih
    Brugada, Pedro
    EUROPACE, 2011, 13 (02): : 205 - 212
  • [23] Four typical pulmonary venous pressure curves displaying the level of occlusion during atrial fibrillation ablation by cryoballoon
    Milhem, Antoine
    Allix-Beguec, Caroline
    Laurencon, Virginie
    Treguer, Frederic
    Cesari, Olivier
    JOURNAL OF ARRHYTHMIA, 2023, 39 (06) : 997 - 1000
  • [24] Chronic Total Occlusion Techniques to Recanalize an Occluded Pulmonary Vein After Atrial Fibrillation Ablation
    Rivero-Santana, Borja
    Jurado-Roman, Alfonso
    Jimenez-Valero, Santiago
    Galeote, Guillermo
    Moreno, Raul
    Merino, Jose Luis
    JOURNAL OF INVASIVE CARDIOLOGY, 2023, 35 (04): : E223 - E224
  • [25] Recanalization of a Chronic Total Pulmonary Vein Occlusion Occurring after Transcatheter Atrial Fibrillation Ablation
    Hussain, Ahmed
    Alway, Thomas
    McCready, James
    Hildick-Smith, David
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2023, 53 : S288 - S291
  • [26] PERSISTENT TRANSUDATIVE EFFUSION AFTER ATRIAL FIBRILLATION ABLATION: A RARE CASE OF PULMONARY VEIN OCCLUSION
    Gayfield, Scott
    Diaz, Philip
    CHEST, 2024, 166 (04) : 5710A - 5710A
  • [27] Pulmonary Venous Occlusion as a Complication of Ablation Therapy for Atrial Fibrillation
    Fernandez-Navarro, Laura
    Moya-Sanchez, Elena
    Segura-Rodriguez, Diego
    Ruiz-Carazo, Eduardo
    ARCHIVOS DE BRONCONEUMOLOGIA, 2018, 54 (06): : 338 - 340
  • [28] Pulmonary Hemorrhage After Cryoballoon Ablation for Pulmonary Vein Isolation in the Treatment of Atrial Fibrillation
    Marti-Almor, Julio
    Jauregui-Abularach, Miguel E.
    Benito, Begona
    Valles, Ermengol
    Bazan, Victor
    Sanchez-Font, Albert
    Vollmer, Ivan
    Altaba, Carmen
    Guijo, Miguel A.
    Hervas, Manel
    Bruguera-Cortada, Jordi
    CHEST, 2014, 145 (01) : 156 - 157
  • [29] Effect of Pulmonary Vein Anatomy and Pulmonary Vein Diameters on Outcome of Cryoballoon Catheter Ablation for Atrial Fibrillation
    Guler, Ekrem
    Guler, Gamze Babur
    Demir, Gultekin Gunhan
    Kizilirmak, Filiz
    Gunes, Haci Murat
    Barutcu, Irfan
    Kilicaslan, Fethi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (08): : 989 - 996
  • [30] Pulmonary vein re-mapping after cryoballoon ablation for atrial fibrillation
    Yokoyama, Kenichi
    Tokuda, Michifumi
    Matsuo, Seiichiro
    Isogai, Ryota
    Tokutake, Kenichi
    Kato, Mika
    Narui, Ryohsuke
    Tanigawa, Shinichi
    Yamashita, Seigo
    Inada, Keiichi
    Yoshimura, Michihiro
    Yamane, Teiichi
    EUROPACE, 2018, 20 (06): : 943 - 948