Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation

被引:16
|
作者
Cauti, Filippo Maria [1 ]
Solimene, Francesco [2 ]
Stabile, Giuseppe [2 ]
Polselli, Marco [1 ]
Schillaci, Vincenzo [2 ]
Arestia, Alberto [2 ]
Shopova, Gergana [2 ]
Iaia, Luigi [2 ]
Giannitti, Carlo Maria [3 ]
Rossi, Pietro [1 ]
Bianchi, Stefano [1 ]
机构
[1] Fatebenefratelli Isola Tiberina, Osped San Giovanni Calib, Arrhythmol Unit, Via PonteQuattro Capi 39, I-00186 Rome, Italy
[2] Clin Montevergine, Arrhythmol Unit, Mercogliano, AV, Italy
[3] EPD Solut, Veenpluis 6, NL-5684 PC Best, Netherlands
来源
关键词
atrial fibrillation; cryoablation; new dielectric imaging system; occlusion tool; pulmonary vein isolation; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; TIME; TACHYARRHYTHMIAS; PREDICTOR;
D O I
10.1111/pace.14130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. Aim of the study The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). Methods We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX-EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new "occlusion tool" software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. Results A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 +/- 17 minutes. Mean fluoroscopy time was 6 +/- 2 minutes. No 30-day complications were observed. Conclusion The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [1] Novel occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation
    Solimene, F.
    Cauti, F. M.
    Stabile, G.
    Rossi, P.
    Schillaci, V
    Polselli, M.
    Arestia, A.
    Iaia, L.
    Shopova, G.
    Bianchi, S.
    EUROPEAN HEART JOURNAL, 2020, 41 : 435 - 435
  • [2] Pulmonary vein occlusion/stenosis after pulmonary vein ablation for atrial fibrillation
    Oral, H
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (04) : 371 - 372
  • [3] Cryoballoon Ablation of Atrial Fibrillation Without Demonstration of Pulmonary Vein Occlusion-The Simplify Cryo Study
    Kuhne, Michael
    Knecht, Sven
    Spies, Florian
    Aeschbacher, Stefanie
    Haaf, Philip
    Zellweger, Michael
    Schaer, Beat
    Osswald, Stefan
    Sticherling, Christian
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [4] Total pulmonary vein occlusion as a consequence of catheter ablation of atrial fibrillation
    Ernst, S
    Ouyang, F
    Goya, M
    Volkmer, M
    Vogtmann, T
    Hebe, J
    Kuck, KH
    EUROPEAN HEART JOURNAL, 2001, 22 : 244 - 244
  • [5] Delayed Diagnosis of Pulmonary Vein Occlusion After Atrial Fibrillation Ablation
    Luby, S.
    Oxman, J.
    Nair, D. Radhakrishnan
    Salguero, B. D.
    Estrella, A. Munoz
    Sud, K.
    Argulian, E.
    Zulueta, J. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [6] Total pulmonary vein occlusion following catheter ablation of atrial fibrillation
    Ernst, S
    Ouyang, F
    Goya, M
    Hoffmann-Riem, M
    Loeber, F
    Volkmer, M
    Kuck, KH
    CIRCULATION, 2001, 104 (17) : 159 - 159
  • [7] Assessment and Management of Pulmonary Vein Occlusion After Atrial Fibrillation Ablation
    Fender, Erin A.
    Widmer, R. Jay
    Hodge, David O.
    Packer, Douglas L.
    Holmes, David R., Jr.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (16) : 1633 - 1639
  • [8] Accuracy comparison of the new and previous Kodex occlusion tool software versions to assess pulmonary vein occlusion in atrial fibrillation cryoablation
    Cauti, F. M.
    Rossi, P.
    Iaia, L.
    Polselli, M.
    Pecere, A.
    Bianchi, S.
    EUROPEAN HEART JOURNAL, 2021, 42 : 386 - 386
  • [9] Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation
    Sunaga, Akihiro
    Masuda, Masaharu
    Asai, Mitsutoshi
    Iida, Osamu
    Okamoto, Shin
    Ishihara, Takayuki
    Nanto, Kiyonori
    Kanda, Takashi
    Tsujimura, Takuya
    Matsuda, Yasuhiro
    Okuno, Syota
    Mano, Toshiaki
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (01) : 115 - 121
  • [10] Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation
    Akihiro Sunaga
    Masaharu Masuda
    Mitsutoshi Asai
    Osamu Iida
    Shin Okamoto
    Takayuki Ishihara
    Kiyonori Nanto
    Takashi Kanda
    Takuya Tsujimura
    Yasuhiro Matsuda
    Syota Okuno
    Toshiaki Mano
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 115 - 121