Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation

被引:16
作者
Cauti, Filippo Maria [1 ]
Solimene, Francesco [2 ]
Stabile, Giuseppe [2 ]
Polselli, Marco [1 ]
Schillaci, Vincenzo [2 ]
Arestia, Alberto [2 ]
Shopova, Gergana [2 ]
Iaia, Luigi [2 ]
Giannitti, Carlo Maria [3 ]
Rossi, Pietro [1 ]
Bianchi, Stefano [1 ]
机构
[1] Fatebenefratelli Isola Tiberina, Osped San Giovanni Calib, Arrhythmol Unit, Via PonteQuattro Capi 39, I-00186 Rome, Italy
[2] Clin Montevergine, Arrhythmol Unit, Mercogliano, AV, Italy
[3] EPD Solut, Veenpluis 6, NL-5684 PC Best, Netherlands
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2021年 / 44卷 / 01期
关键词
atrial fibrillation; cryoablation; new dielectric imaging system; occlusion tool; pulmonary vein isolation; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; TIME; TACHYARRHYTHMIAS; PREDICTOR;
D O I
10.1111/pace.14130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. Aim of the study The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). Methods We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX-EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new "occlusion tool" software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. Results A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 +/- 17 minutes. Mean fluoroscopy time was 6 +/- 2 minutes. No 30-day complications were observed. Conclusion The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 29 条
[1]   Cryoballoon or Radiofrequency Ablation for Atrial Fibrillation Assessed by Continuous Monitoring A Randomized Clinical Trial [J].
Andrade, Jason G. ;
Champagne, Jean ;
Dubuc, Marc ;
Deyell, Marc W. ;
Verma, Atul ;
Macle, Laurent ;
Leong-Sit, Peter ;
Novak, Paul ;
Badra-Verdu, Mariano ;
Sapp, John ;
Mangat, Iqwal ;
Khoo, Clarence ;
Steinberg, Christian ;
Bennett, Matthew T. ;
Tang, Anthony S. L. ;
Khairy, Paul ;
Parkash, Ratika ;
Guerra, Peter ;
Dyrda, Katia ;
Rivard, Lena ;
Racine, Normand ;
Sterns, Lawrence ;
Leather, Rick ;
Seifer, Colette ;
Jolly, Umjeet ;
Raymond, Jean-Marc ;
Roux, Jean-Francois ;
Nault, Isabelle ;
Sarrazin, Jean-Francois ;
Ramanathan, Krishnan ;
Cheung, Christopher ;
Fordyce, Christopher ;
McKinney, Jimmy ;
Luong, Christina ;
Rizkallah, Jacques ;
Angaran, Paul ;
Ha, Andrew ;
Glover, Benedict ;
Skanes, Allan ;
Gula, Lorne .
CIRCULATION, 2019, 140 (22) :1779-1788
[2]   Predictive value of early atrial tachyarrhythmias recurrence after circumferential anatomical pulmonary vein ablation [J].
Bertaglia, E ;
Stabile, G ;
Senatore, G ;
Zoppo, F ;
Turco, P ;
Amellone, C ;
De Simone, A ;
Fazzari, M ;
Pascotto, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (05) :366-371
[3]  
Calkins H, 2017, HEART RHYTHM, V14, pE445, DOI [10.1093/europace/eux275, 10.1016/j.hrthm.2017.07.009, 10.1016/j.hrthm.2017.05.012]
[4]   Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-Ttrial [J].
Chun, K. R. Julian ;
Stich, Marie ;
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Perrotta, Laura ;
Dugo, Daniela ;
Bologna, Fabrizio ;
Schmidt, Boris .
HEART RHYTHM, 2017, 14 (04) :495-500
[5]   On the Quest for the Best Freeze Predictors of Late Pulmonary Vein Reconnections After Second-Generation Cryoballoon Ablation [J].
Ciconte, Giuseppe ;
Mugnai, Giacomo ;
Sieira, Juan ;
Velagic, Vedran ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Hunuk, Burak ;
Stroeker, Erwin ;
Conte, Giulio ;
Di Giovanni, Giacomo ;
Baltogiannis, Giannis ;
Wauters, Kristel ;
Brugada, Pedro ;
de Asmundis, Carlo ;
Chierchia, Gian-Battista .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (06) :1359-1365
[6]   Single freeze strategy with the second- generation cryballoon for atrial fibrillation: a multicenter international retrospective analysis in a large cohort of patients [J].
De Regibus, Valentina ;
Iacopino, Saverio ;
Abugattas, Juan Pablo ;
Coutino, Hugo Enrique ;
Mugnai, Giacomo ;
Storti, Cesare ;
Conte, Giulio ;
Auricchio, Angelo ;
Moran, Darragh ;
Stroker, Erwin ;
Marroquin, Luis ;
Takarada, Ken ;
Choudhury, Rajin ;
de Asmundis, Carlo ;
Brugada, Pedro ;
Chierchia, Gian-Battista .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (02) :173-180
[7]   Time-to-Effect-Based Dosing Strategy for Cryoballoon Ablation in Patients With Paroxysmal Atrial Fibrillation Results of the plusONE Multicenter Randomized Controlled Noninferiority Trial [J].
Ferrero-de-Loma-Osorio, Angel ;
Garcia-Fernandez, Amaya ;
Castillo-Castillo, Jesus ;
Izquierdo-de-Francisco, Maite ;
Ibanez-Criado, Alicia ;
Moreno-Arribas, Jose ;
Martinez, Angel ;
Bertomeu-Gonzalez, Vicente ;
Lopez-Mases, Patricia ;
Ajo-Ferrer, Maria ;
Nunez, Carlos ;
Bondanza-Saavedra, Lourdes ;
Miguel Sanchez-Gomez, Juan ;
Gabriel Martinez-Martinez, Juan ;
Javier Chorro-Gasco, Francisco ;
Ruiz-Granell, Ricardo .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2017, 10 (12)
[8]   Cryoballoon temperature predicts acute pulmonary vein isolation [J].
Fuernkranz, Alexander ;
Koester, Ilka ;
Chun, K. R. Julian ;
Metzner, Andreas ;
Mathew, Shibu ;
Konstantinidou, Melanie ;
Ouyang, Feifan ;
Kuck, Karl Heinz .
HEART RHYTHM, 2011, 8 (06) :821-825
[9]   Atrial flow dynamics as a determinant of tissue temperature during balloon cryoablation [J].
Ghosh, Justin ;
McGuire, Mark A. .
EUROPACE, 2018, 20 :F451-F457
[10]   Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation [J].
Ghosh, Justin ;
Martin, Andrew ;
Keech, Anthony C. ;
Chan, Kim H. ;
Gomes, Sean ;
Singarayar, Suresh ;
McGuire, Mark A. .
HEART RHYTHM, 2013, 10 (09) :1311-1317