New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography

被引:51
作者
Fernandez-Ramos, C. [1 ]
Satinsky, D. [1 ]
Solich, P. [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Pharm, Hradec Kralove 50005, Czech Republic
关键词
Chromatography; Carbamates; Pyrethroids; Large volume sample injection; On-line solid phase extraction (on-line SPE); Surface water; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; LARGE-VOLUME INJECTION; GAS-CHROMATOGRAPHY; TRACE ANALYSIS; FLUORESCENCE DETECTION; POLAR PESTICIDES; DERIVATIZATION; RESIDUES;
D O I
10.1016/j.talanta.2014.06.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new HPLC column-switching method using large volume sample injection and fused-core columns for on-line solid phase extraction have been developed for the determination of the following carbamates and pyrethroids: aldicarb, carbaryl, pirimicarb, carbofuran, kadethrin, flumethrin, fenpropathrin, fenoxycarb, tau-fluvalinate and fenvalerate, in surface water samples. Sudan I was used as internal standard. The proposed method was performed using 100 pi sample injection followed by an on-line solid phase extraction procedure and finally the compounds were identified and quantified by liquid chromatography with ultraviolet detection. The separation was carried out on C-18 reversed phase column based on fused-core particle technology. The influence of the injected sample volume, the variables affecting to SPE process and the conditions for the separation on an analytical column, were studied and optimized. The limits of detection ranged from 5.5 to 8.9 mu g L-1, and limits of quantification from 18.4 to 29.7 mu g L-1, while inter- and intra-day variability was under 15%. This new analytical procedure was satisfactorily applied for the determination of these organic pollutants in surface water samples located in Czech Republic. Concentration levels were found for some of these pollutants up to 26.11 mu g L-1 in the river Elbe and up to 34.53 mu g L-1 in the closed lakes samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:579 / 585
页数:7
相关论文
共 37 条
[1]  
[Anonymous], 2000, STATGR PLUS VERS 5 0
[2]  
[Anonymous], 2011, 733R11001 US EPA
[3]   Green Analytical Chemistry [J].
Armenta, S. ;
Garrigues, S. ;
de la Guardia, M. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (06) :497-511
[4]   Pesticide concentrations in maternal and umbilical cord sera and their relation to birth outcomes in a population of pregnant women and newborns in New Jersey [J].
Barr, Dana Boyd ;
Ananth, Cande V. ;
Yan, Xiaoyong ;
Lashley, Susan ;
Smulian, John C. ;
Ledoux, Thomas A. ;
Hore, Paromita ;
Robson, Mark G. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (04) :790-795
[5]   Detection of s-triazine pesticides in natural waters by modified large-volume direct injection HPLC [J].
Beale, David J. ;
Kaserzon, Sarit L. ;
Porter, Nichola A. ;
Roddick, Felicity A. ;
Carpenter, Peter D. .
TALANTA, 2010, 82 (02) :668-674
[6]   Determination of six pyrethroid insecticides in fruit juice samples using dispersive liquid-liquid microextraction combined with high performance liquid chromatography [J].
Boonchiangma, Suthasinee ;
Ngeontae, Wittaya ;
Srijaranai, Supalax .
TALANTA, 2012, 88 :209-215
[7]   Validation of method for determination of different classes of pesticides in aqueous samples by dispersive liquid-liquid microextraction with liquid chromatography-tandem mass spectrometric detection [J].
Caldas, Sergiane Souza ;
Costa, Fabiane Pinho ;
Primel, Ednei Gilberto .
ANALYTICA CHIMICA ACTA, 2010, 665 (01) :55-62
[8]   Low-density extraction solvent-based solvent terminated dispersive liquid-liquid microextraction combined with gas chromatography-tandem mass spectrometry for the determination of carbamate pesticides in water samples [J].
Chen, Hao ;
Chen, Ruiwen ;
Li, Shengqing .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) :1244-1248
[9]   Determination of carbamate, phenylurea and phenoxy acid herbicide residues by gas chromatography after potassium tert-butoxide/dimethyl sulphoxide/ethyl iodide derivatization reaction [J].
Crespo-Corral, E. ;
Santos-Delgado, M. J. ;
Polo-Diez, L. M. ;
Soria, A. C. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1209 (1-2) :22-28
[10]   Detection and quantification limits: origins and historical overview [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :127-134