Development of a Coded Aperture X-Ray Backscatter Imager for Explosive Device Detection

被引:28
作者
Faust, Anthony A. [1 ]
Rothschild, Richard E. [2 ]
Leblanc, Philippe [2 ]
McFee, John Elton [1 ]
机构
[1] Def R&D Canada Suffield, Medicine Hat, AB T1A 8K6, Canada
[2] Univ Calif San Diego, Ctr Astrophys & Space Sci, La Jolla, CA 92093 USA
关键词
Coded aperture; Compton scattering; explosives detection; nuclear imaging; x-ray imaging; x-ray scattering; x-ray spectroscopy; ARRAYS;
D O I
10.1109/TNS.2008.2009537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Defence R&D Canada has an active research and development program on detection of explosive devices using nuclear methods. One system under development is a coded aperture-based X-ray backscatter imaging detector designed to provide sufficient speed, contrast and spatial resolution to detect antipersonnel landmines and improvised explosive devices. The successful development of a hand-held imaging detector requires, among other things, a light-weight, ruggedized detector with low power requirements, supplying high spatial resolution. The University of California, San Diego-designed HEXIS detector provides a modern, large area, high-temperature CZT imaging surface, robustly packaged in a light-weight housing with sound mechanical properties. Based on the potential for the HEMS detector to be incorporated as the detection element of a hand-held imaging detector, the authors initiated a collaborative effort to demonstrate the capability of a coded aperture-based X-ray backscatter imaging detector. This paper will discuss the land-mine and IED detection problem and review the coded aperture technique. Results from initial proof-of-principle experiments will then be reported.
引用
收藏
页码:299 / 307
页数:9
相关论文
共 29 条
[1]   Near-field artifact reduction in planar coded aperture imaging [J].
Accorsi, R ;
Lanza, RC .
APPLIED OPTICS, 2001, 40 (26) :4697-4705
[2]   Optimal coded aperture patterns for improved SNR in nuclear medicine imaging [J].
Accorsi, R ;
Gasparini, F ;
Lanza, RC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 474 (03) :273-284
[3]   The HYDAD-D antipersonnel landmine detector [J].
Brooks, FD ;
Drosg, M .
APPLIED RADIATION AND ISOTOPES, 2005, 63 (5-6) :565-574
[4]   MULTIPLEX IMAGING WITH MULTIPLE-PINHOLE CAMERAS [J].
BROWN, C .
JOURNAL OF APPLIED PHYSICS, 1974, 45 (04) :1806-1811
[5]   CODED APERTURE IMAGING IN X-RAY AND GAMMA-RAY ASTRONOMY [J].
CAROLI, E ;
STEPHEN, JB ;
DICOCCO, G ;
NATALUCCI, L ;
SPIZZICHINO, A .
SPACE SCIENCE REVIEWS, 1987, 45 (3-4) :349-403
[6]  
COLEMAN W, 1974, NUCL METHODS MINE DE
[7]   Landmine detection with the neutron backscattering method [J].
Datema, CP ;
Bom, VR ;
van Eijk, CWE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :1087-1091
[8]  
DUGAN ET, 2001, DAAG559810400 USA RE
[9]  
Dyson N.A., 1990, X-Rays in Atomic and Nuclear Physics
[10]   Detection of explosive devices using X-ray backscatter radiation [J].
Faust, AA .