Catheter closure of moderate to large sized patent ductus arteriosus using the simultaneous double or triple coil technique

被引:2
作者
Akagi, T [1 ]
Mizumoto, Y [1 ]
Iemura, M [1 ]
Tananari, Y [1 ]
Ishii, M [1 ]
Maeno, Y [1 ]
Kato, H [1 ]
机构
[1] Kurume Univ, Dept Pediat, Sch Med, Fukuoka 8300011, Japan
关键词
catheter; coil; ductus; intervention; outcome;
D O I
10.1046/j.1442-200X.2001.01460.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Although the clinical experience with transcatheter closure of the patent ductus arteriosus using the coils has grown rapidly, one important complication of this procedure using the conventional Gianturco coil was the migration of coils into peripheral vessels. This is especially for patients with a relatively larger size ductus and the risk for such complications could be increased, In this situation. the detachable coil may have some technical benefits to perform coil occlusion and reduce the incidence of complications. Methods: We describe the clinical efficacy of a simultaneous double or triple coil Occlusion technique using the Cook detachable coil or bioptome delivered 0.052 inch Gianturco coil to close the ductus arteriosus. This was performed in patients whose ductus diameter was greater than 3.0 mm. Results: From February 1995 to December 2000, 118 patients with patent ductus arteriosus were treated by coil occlusion using Cook detachable coils, of whom 58 patients whose minimum diameter of ductus greater than or equal to 3.0 mm were reviewed. All patients had successful placement of coils. According to the evaluation by color flow mapping, a trivial shunt was observed in 17 patients (29%) within 24 h after the procedure. In 11 out of 17 patients, a residual shunt was not detected 1 month after the procedure. At 6 months after the procedure, the residual shunt was detected only in three patients. Conclusions: Although this study did not calculate the statistical significance between detachable and nondetachable coils in term of occlusion rate, our institutional experience Suggests that the simultaneous double or triple coil technique using the detachable or 0.052 inch Gianturco coils can reduce the prevalence of coil migration or complications.
引用
收藏
页码:536 / 541
页数:6
相关论文
共 15 条
[1]   Coil occlusion of patent ductus arteriosus with detachable coils [J].
Akagi, T ;
Hashino, K ;
Sugimura, T ;
Ishii, M ;
Eto, G ;
Kato, H .
AMERICAN HEART JOURNAL, 1997, 134 (03) :538-543
[2]  
Akagi T, 2001, J Interv Cardiol, V14, P91, DOI 10.1111/j.1540-8183.2001.tb00718.x
[3]   PERCUTANEOUS CLOSURE OF THE SMALL (LESS-THAN-2.5 MM) PATENT DUCTUS-ARTERIOSUS USING COIL EMBOLIZATION [J].
CAMBIER, PA ;
KIRBY, WC ;
WORTHAM, DC ;
MOORE, JW .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (08) :815-816
[4]  
Grifka RG, 2000, CATHETER CARDIO INTE, V49, P301, DOI 10.1002/(SICI)1522-726X(200003)49:3<301::AID-CCD16>3.0.CO
[5]  
2-V
[6]   RESULTS OF ANTEROGRADE TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS USING SINGLE OR MULTIPLE GIANTURCO COILS [J].
HIJAZI, ZM ;
GEGGEL, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (09) :925-929
[7]   ANGIOGRAPHIC CLASSIFICATION OF THE ISOLATED, PERSISTENTLY PATENT DUCTUS-ARTERIOSUS AND IMPLICATIONS FOR PERCUTANEOUS CATHETER OCCLUSION [J].
KRICHENKO, A ;
BENSON, LN ;
BURROWS, P ;
MOES, CAF ;
MCLAUGHLIN, P ;
FREEDOM, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (12) :877-880
[8]   TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH GIANTURCO COILS [J].
LLOYD, TR ;
FEDDERLY, R ;
MENDELSOHN, AM ;
SANDHU, SK ;
BEEKMAN, RH .
CIRCULATION, 1993, 88 (04) :1412-1420
[9]  
LLOYD TR, 1995, CIRCULATION, V92, P1
[10]   Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results [J].
Masura, J ;
Walsh, KP ;
Thanopoulous, B ;
Chan, C ;
Bass, J ;
Goussous, Y ;
Gavora, P ;
Hijazi, ZM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (04) :878-882