Reduction of Particles in the Operating Room Using Ultraviolet Air Disinfection and Recirculation Units

被引:28
作者
Curtis, Gannon L. [1 ]
Faour, Mhamad [1 ]
Jawad, Michael [1 ]
Klika, Alison K. [1 ]
Barsoum, Wael K. [1 ]
Higuera, Carlos A. [1 ]
机构
[1] Cleveland Clin, Dept Orthopaed Surg, 9500 Euclid Ave, Cleveland, OH 44195 USA
关键词
total joint arthroplasty; ultraviolet; air particles; infection; operating room traffic; PERIPROSTHETIC JOINT INFECTION; AIRBORNE CONTAMINATION; WOUND CONTAMINATION; TOTAL HIP; SURGERY; ARTHROPLASTY; REPLACEMENT; THEATERS; PREVENTION; BACTERIA;
D O I
10.1016/j.arth.2017.11.052
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Airborne bacteria are a major source for wound contamination during total joint arthroplasty. Crystalline ultraviolet C (C-UVC) filter units were designed to disinfect and recirculate air in the operating room (OR). This preliminary study assessed the particle reducing capacity of C-UVC units in a highly controlled OR setting. Methods: A particle counter was deployed in a positive-pressure OR to measure total and viable particle counts (TPC/VPC). Thirty 23-minute experiments were performed. At 4 designated times a person would walk through the door to mimic OR traffic. Ten experiments were performed as controls, 10 experiments used a C-UVC unit 4 meters (m) from the door, and 10 cases with the C-UVC unit at 8 m. Outcomes included overall, change (D), and maximum TPC/VPC. Mann-Whitney U-tests determined statistical differences in TPC/VPC. Results: Compared to controls, the cases with the C-UVC unit at 4 m had significantly lower particle levels. Overall TPC/VPC, changes in TPC/VCP, and maximum TPC/VPC were all significantly lower (P <.05) in the C-UVC unit (4 m) group compared to the controls. The C-UVC at 8 m significantly reduced TPC in all 3 outcomes (P <.05) compared to controls; however, it did not significantly reduce changes in VPC (P = .107) and maximum VPC (P = .052). There were no significant differences in any outcomes between the 4 m and 8 m group. Conclusion: C-UVC units have shown to be capable of significantly reducing TPC and VPC in a highly controlled OR setting. Reducing airborne particles using C-UVC units may reduce infection rates following total joint arthroplasty. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:S196 / S200
页数:5
相关论文
共 32 条
[1]   Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study [J].
Agodi, A. ;
Auxilia, F. ;
Barchitta, M. ;
Cristina, M. L. ;
D'Alessandro, D. ;
Mura, I. ;
Nobile, M. ;
Pasquarella, C. .
JOURNAL OF HOSPITAL INFECTION, 2015, 90 (03) :213-219
[2]   Air contamination for predicting wound contamination in clean surgery: A large multicenter study [J].
Birgand, Gabriel ;
Toupet, Gaelle ;
Rukly, Stephane ;
Antoniotti, Gilles ;
Deschamps, Marie-Noelle ;
Lepelletier, Didier ;
Pornet, Carole ;
Stern, Jean Baptiste ;
Vandamme, Yves-Marie ;
van der Mee-Marquet, Nathalie ;
Timsit, Jean-Francois ;
Lucet, Jean-Christophe .
AMERICAN JOURNAL OF INFECTION CONTROL, 2015, 43 (05) :516-521
[3]   The impact of infection after total hip arthroplasty on hospital and surgeon resource utilization [J].
Bozic, KJ ;
Ries, MD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1746-1751
[4]   VENTILATION CONDITIONS AND AIR-BORNE BACTERIA AND PARTICLES IN OPERATING-THEATERS - PROPOSED SAFE ECONOMIES [J].
CLARK, RP ;
REED, PJ ;
SEAL, DV ;
STEPHENSON, ML .
JOURNAL OF HYGIENE, 1985, 95 (02) :325-335
[5]   Real-time measurements of airborne biologic particles using fluorescent particle counter to evaluate microbial contamination: Results of a comparative study in an operating theater [J].
Dai, Chunyang ;
Zhang, Yan ;
Ma, Xiaoling ;
Yin, Meiling ;
Zheng, Haiyang ;
Gu, Xuejun ;
Xie, Shaoqing ;
Jia, Hengmin ;
Zhang, Liang ;
Zhang, Weijun .
AMERICAN JOURNAL OF INFECTION CONTROL, 2015, 43 (01) :78-81
[6]   Environmental controls in operating theatres [J].
Dharan, S ;
Pittet, D .
JOURNAL OF HOSPITAL INFECTION, 2002, 51 (02) :79-84
[7]   Current Concepts for Clean Air and Total Joint Arthroplasty: Laminar Airflow and Ultraviolet Radiation: A Systematic Review [J].
Evans, Richard P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (04) :945-953
[8]   Reduction of Airborne Bacterial Burden in the OR by Installation of Unidirectional Displacement Airflow (UDF) Systems [J].
Fischer, Sebastian ;
Thieves, Martin ;
Hirsch, Tobias ;
Fischer, Klaus-Dieter ;
Hubert, Helmine ;
Bepler, Steffen ;
Seipp, Hans-Martin .
MEDICAL SCIENCE MONITOR, 2015, 21 :2367-2374
[9]   The Gown-glove Interface Is a Source of Contamination: A Comparative Study [J].
Fraser, James F. ;
Young, Simon W. ;
Valentine, Kimberly A. ;
Probst, Nicholas E. ;
Spangehl, Mark J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (07) :2291-2297
[10]   Importance of air quality and related factors in the prevention of infection in orthopaedic implant surgery [J].
Gosden, PE ;
MacGowan, AP ;
Bannister, GC .
JOURNAL OF HOSPITAL INFECTION, 1998, 39 (03) :173-180