A General and Accurate Measurement Procedure for the Detection of Power Losses Variations in Permanent Magnet Synchronous Motor Drives

被引:10
作者
Caruso, Massimo [1 ]
Di Tommaso, Antonino Oscar [1 ]
Lisciandrello, Giuseppe [1 ]
Mastromauro, Rosa Anna [2 ]
Miceli, Rosario [1 ]
Nevoloso, Claudio [1 ]
Spataro, Ciro [1 ]
Trapanese, Marco [1 ]
机构
[1] Univ Palermo, Dept Engn, Viale Sci,Parco DOrleans, I-90128 Palermo, Italy
[2] Univ Florence, Dept Informat Engn, I-50139 Florence, Italy
基金
欧盟地平线“2020”;
关键词
power loss minimization; speed control drive systems; efficiency measurement; IPMSM; MINIMIZATION; TORQUE;
D O I
10.3390/en13215770
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The research of innovative solutions to improve the efficiency of electric drives is of considerable interest to challenges related to energy savings and sustainable development. In order to successfully validate the adoption of new and innovative software or hardware solutions in the field of electric drives, accurate measurement procedures for either efficiency or power losses are needed. Moreover, high accuracy and expensive measurement equipment are required to satisfy international standard prescriptions. In this scenario, this paper describes an accurate measurement procedure, which is independent of the accuracy of the adopted instrumentation, for the power losses variations involved in electrical drives, namely Delta Delta P, useful to detect the efficiency enhancement (or power losses reduction) due to the real-time modification of the related control algorithm. The goal is to define a valuable measurement procedure capable of comparing the impact of different control algorithms on electric drive performance. This procedure is carried out by experimentally verifying the action of different control algorithms by the use of a Field Oriented Control (FOC) with different values of the direct-axis current component (i.e., I-d = 0 A and I-d = -1 A) applied for fixed working conditions in terms of speed and load torque. Two different measurement systems of power losses, each one characterized by different accuracy and cost, are taken into account for the validation of the proposed method. An investigation is, then, carried out, based on the comparison between the measurements acquired by both instrumentations, for different working conditions in terms of load and speed, highlighting that the uncertainty generated by systematic errors does not affect the Delta Delta P measurements. The results reported in this work demonstrate how the Delta Delta P parameter can be used as a valuable index for the characterization of the power drive system, which can also be evaluated even with low-accuracy instrumentation.
引用
收藏
页数:19
相关论文
共 33 条
  • [1] Aarniovuori L, 2014, 2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P323, DOI 10.1109/ICELMACH.2014.6960200
  • [2] Agamloh E.B., 2015, Pulp and Paper Industry Conference (PPIC), 2015 61st IEEE, P1, DOI [10.1109/PPIC.2015.7165864, DOI 10.1109/PPIC.2015.7165864]
  • [3] [Anonymous], 6003421 IEC
  • [4] [Anonymous], 6003423 IEC
  • [5] [Anonymous], 6180092 IEC
  • [6] [Anonymous], 600342 IEC
  • [7] [Anonymous], 6180091 IEC
  • [8] Antonello R, 2015, 2015 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DIAGNOSIS (WEMDCD), P248, DOI 10.1109/WEMDCD.2015.7194537
  • [9] Uncertainty Issues in Direct and Indirect Efficiency Determination for Three-Phase Induction Motors: Remarks About the IEC 60034-2-1 Standard
    Bucci, Giovanni
    Ciancetta, Fabrizio
    Fiorucci, Edoardo
    Ometto, Antonio
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (12) : 2701 - 2716
  • [10] Caruso M, 2019, INT J RENEW ENERGY R, V9, P374