Information transfer between large and small two-dimensional polyacrylamide gel electrophoresis

被引:0
|
作者
Felley-Bosco, E
Demalte, I
Barcelo, S
Sanchez, JC
Hochstrasser, DF
Schlegel, W
Reymond, MA
机构
[1] Univ Lausanne, Inst Pharmacol & Toxicol, CH-1005 Lausanne, Switzerland
[2] Lab Chim Clin, Geneva, Switzerland
[3] Fdn Rech Med, Geneva, Switzerland
[4] Univ Hosp, Dept Surg, Magdeburg, Germany
关键词
two-dimensional polyacrylamide gel electrophoresis; information transfer; colon carcinoma;
D O I
10.1002/(SICI)1522-2683(19991201)20:18<3508::AID-ELPS3508>3.0.CO;2-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To determine the feasibility of data transfer, an interlaboratory comparison was conducted on colon carcinoma cell line (DLD-1) proteins resolved by two-dimensional polyacrylamide gel electrophoresis either on small (6 x 7 cm) or large (16x18 cm) gels. The gels were silver-stained and scanned by laser densitometry, and the image obtained was analyzed using Melanie software. The number of spots detected was 1337+/-161 vs. 2382 +/- 176 for small vs. large format gels, respectively. After gel calibration using landmarks determined using pl and M-r markers, large- and small-format gels were matched and 712+/-36 proteins were found on both types of gels. Having performed accurate gel matching it was possible to acquire additional information after accessing a 2-D PAGE reference database (http://www.expasy.ch/ cgibin/map2/ def?DLD1_HUMAN). Thus, the difference in gel size is not an obstacle for data transfer. This will facilitate exchanges between laboratories or consultation concerning existing databases.
引用
收藏
页码:3508 / 3513
页数:6
相关论文
共 50 条
  • [31] TWO-DIMENSIONAL POLYACRYLAMIDE-GEL ELECTROPHORESIS OF HYMENOPTERA VENOM AND VENOM SAC EXTRACTS
    WOOD, CL
    HOFFMAN, DR
    TOXICON, 1983, 21 (02) : 291 - &
  • [32] A modification for the improved analysis of differential protein accumulation by two-dimensional polyacrylamide gel electrophoresis
    Ekramoddoullah, AKM
    Tan, YC
    PHYTOCHEMICAL ANALYSIS, 1998, 9 (04) : 159 - 161
  • [33] Characterization of the major polypeptides of equine seminal plasma by two-dimensional polyacrylamide gel electrophoresis
    Frazer, GS
    Bucci, DM
    THERIOGENOLOGY, 1996, 46 (08) : 1389 - 1402
  • [34] ANALYSIS OF AMNIOTIC-FLUID PROTEINS BY TWO-DIMENSIONAL POLYACRYLAMIDE-GEL ELECTROPHORESIS
    KRONQUIST, KE
    CRANDALL, BF
    CLINICAL RESEARCH, 1982, 30 (01): : A118 - A118
  • [35] Phosphoproteome Profiling Using a Fluorescent Phosphosensor Dye in Two-Dimensional Polyacrylamide Gel Electrophoresis
    Mieko Otani
    Taizo Taniguchi
    Akiko Sakai
    Jouji Seta
    Keiichi Kadoyama
    Tooru Nakamura-Hirota
    Shogo Matsuyama
    Keiji Sano
    Masaoki Takano
    Applied Biochemistry and Biotechnology, 2011, 164 : 804 - 818
  • [36] PROGRAMMED AGING OR ERROR CATASTROPHE - AN EXAMINATION BY TWO-DIMENSIONAL POLYACRYLAMIDE-GEL ELECTROPHORESIS
    JOHNSON, TE
    MCCAFFREY, G
    MECHANISMS OF AGEING AND DEVELOPMENT, 1985, 30 (03) : 285 - 297
  • [37] USE OF TWO-DIMENSIONAL POLYACRYLAMIDE-GEL ELECTROPHORESIS TO IDENTIFY AND CLASSIFY RHIZOBIUM STRAINS
    ROBERTS, GP
    LEPS, WT
    SILVER, LE
    BRILL, WJ
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1980, 39 (02) : 414 - 422
  • [39] Plant protein isolation and stabilization for enhanced resolution of two-dimensional polyacrylamide gel electrophoresis
    Sarma, Annamraju D.
    Oehrle, Nathan W.
    Emerich, David W.
    ANALYTICAL BIOCHEMISTRY, 2008, 379 (02) : 192 - 195
  • [40] A dynamic two-dimensional polyacrylamide gel electrophoresis database:: The mycobacterial proteome via Internet
    Mollenkopf, HJ
    Jungblut, PR
    Raupach, B
    Mattow, J
    Lamer, S
    Zimny-Arndt, U
    Schaible, UE
    Kaufmann, SHE
    ELECTROPHORESIS, 1999, 20 (11) : 2172 - 2180