Limited-angle tomography for analyzer-based phase-contrast x-ray imaging

被引:1
作者
Majidi, Keivan [1 ]
Wernick, Miles N. [1 ]
Li, Jun [2 ]
Muehleman, Carol [2 ]
Brankov, Jovan G. [1 ]
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] Rush Univ, Med Ctr, Dept Biochem, Chicago, IL 60612 USA
关键词
x-ray; phase contrast; tomosynthesis; limited angle tomography; COMPUTED-TOMOGRAPHY; BREAST-CANCER; RADIOGRAPHY; REFRACTION; CT; RECONSTRUCTION; IMPLEMENTATION; IMAGES;
D O I
10.1088/0031-9155/59/13/3483
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.
引用
收藏
页码:3483 / 3500
页数:18
相关论文
共 50 条
  • [31] Hard X-ray phase-contrast imaging
    Gao, DC
    Pogany, A
    Stevenson, AW
    Gureyev, T
    Wilkins, SW
    Mai, ZH
    ACTA PHYSICA SINICA, 2000, 49 (12) : 2357 - 2368
  • [32] X-Ray Phase-Contrast Technology in Breast Imaging: Principles, Options, and Clinical Application
    Taba, Seyedamir Tavakoli
    Gureyev, Timur E.
    Alakhras, Maram
    Lewis, Sarah
    Lockie, Darren
    Brennan, Patrick C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (01) : 133 - 145
  • [33] Redefining the lower statistical limit in x-ray phase-contrast imaging
    Marschner, M.
    Birnbacher, L.
    Willner, M.
    Chabior, M.
    Fehringer, A.
    Herzen, J.
    Noel, P. B.
    Pfeiffer, F.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [34] A feasibility study of X-ray phase-contrast mammographic tomography at the Imaging and Medical beamline of the Australian Synchrotron
    Nesterets, Yakov I.
    Gureyev, Timur E.
    Mayo, Sheridan C.
    Stevenson, Andrew W.
    Thompson, Darren
    Brown, Jeremy M. C.
    Kitchen, Marcus J.
    Pavlov, Konstantin M.
    Lockie, Darren
    Brun, Francesco
    Tromba, Giuliana
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1509 - 1523
  • [35] Biases of estimated signals in x-ray analyzer-based imaging
    Xia, Jianlin
    Xu, Wen
    Zhou, Ruicheng
    Shi, Xiaomin
    Ren, Kun
    Chen, Heng
    Wang, Zhili
    CHINESE PHYSICS B, 2020, 29 (06)
  • [36] Noise texture and signal detectability in propagation-based x-ray phase-contrast tomography
    Chou, Cheng-Ying
    Anastasio, Mark A.
    MEDICAL PHYSICS, 2010, 37 (01) : 270 - 281
  • [37] Truncation Correction for X-ray Phase-Contrast Region-of-Interest Tomography
    Felsner, Lina
    Kaeppler, Sebastian
    Maier, Andreas
    Riess, Christian
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 : 625 - 639
  • [38] X-ray Phase-Contrast Computed Tomography for Soft Tissue Imaging at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron
    Arhatari, Benedicta D.
    Stevenson, Andrew W.
    Abbey, Brian
    Nesterets, Yakov I.
    Maksimenko, Anton
    Hall, Christopher J.
    Thompson, Darren
    Mayo, Sheridan C.
    Fiala, Tom
    Quiney, Harry M.
    Taba, Seyedamir T.
    Lewis, Sarah J.
    Brennan, Patrick C.
    Dimmock, Matthew
    Hausermann, Daniel
    Gureyev, Timur E.
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [39] Grating-based X-ray phase-contrast imaging at PETRA III
    Hipp, A.
    Beckmann, F.
    Lytaev, P.
    Greving, I.
    Lottermoser, L.
    Dose, T.
    Kirchhof, R.
    Burmester, H.
    Schreyer, A.
    Herzen, J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [40] X-ray phase-contrast CT imaging of the acupoints based on synchrotron radiation
    Chenglin, Liu
    Xiaohua, Wang
    Hua, Xu
    Fang, Liu
    Ruishan, Dang
    Dongming, Zhang
    Xinyi, Zhang
    Honglan, Xie
    Tiqiao, Xiao
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2014, 196 : 80 - 84