Limited-angle tomography for analyzer-based phase-contrast x-ray imaging

被引:1
|
作者
Majidi, Keivan [1 ]
Wernick, Miles N. [1 ]
Li, Jun [2 ]
Muehleman, Carol [2 ]
Brankov, Jovan G. [1 ]
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] Rush Univ, Med Ctr, Dept Biochem, Chicago, IL 60612 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 13期
关键词
x-ray; phase contrast; tomosynthesis; limited angle tomography; COMPUTED-TOMOGRAPHY; BREAST-CANCER; RADIOGRAPHY; REFRACTION; CT; RECONSTRUCTION; IMPLEMENTATION; IMAGES;
D O I
10.1088/0031-9155/59/13/3483
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.
引用
收藏
页码:3483 / 3500
页数:18
相关论文
共 50 条
  • [1] Analyzer-based phase-contrast x-ray imaging of carotid plaque microstructure
    Appel, Alyssa A.
    Chou, Cheng-Ying
    Greisler, Howard P.
    Larson, Jeffery C.
    Vasireddi, Sunil
    Zhong, Zhong
    Anastasio, Mark A.
    Brey, Eric M.
    AMERICAN JOURNAL OF SURGERY, 2012, 204 (05): : 631 - 636
  • [2] Analyzer-based phase-contrast imaging system using a micro focus x-ray source
    Zhou, Wei
    Majidi, Keivan
    Brankov, Jovan G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (08):
  • [3] In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs
    Coan, Paola
    Wagner, Andreas
    Bravin, Alberto
    Diemoz, Paul C.
    Keyrilainen, Jani
    Mollenhauer, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (24): : 7649 - 7662
  • [4] Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging
    Majidi, Keivan
    Li, Jun
    Muehleman, Carol
    Brankov, Jovan G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (08): : 1877 - 1897
  • [5] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [6] Dynamical diffraction model for phase-contrast analyzer-based imaging
    Molodkin, V. B.
    Velikhovskyi, G. O.
    Lizunova, S., V
    Lizunov, V. V.
    OPTICS COMMUNICATIONS, 2019, 439 : 1 - 7
  • [7] X-ray limited-angle tomography of cracks
    Likhachev, N. A.
    INTERNATIONAL CONFERENCE ON CONSTRUCTION, ARCHITECTURE AND TECHNOSPHERE SAFETY (ICCATS 2020), 2020, 962
  • [8] Simulation tools for analyzer-based X-ray phase contrast imaging system with a conventional X-ray source
    Caudevilla, Oriol
    Zhou, Wei
    Stoupin, Stanislav
    Verman, Boris
    Brankov, J. G.
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS V, 2016, 9964
  • [9] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [10] Source effects in analyzer-based X-ray phase contrast imaging with conventional sources
    Hoennicke, M. G.
    Manica, J.
    Mazzaro, I.
    Cusatis, C.
    Huang, X. -R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (11):