Evaluation of oculokinetic perimetry

被引:4
作者
Chia, WLA
Goldberg, I
Bauman, A
机构
[1] Univ Sydney, Save Sight Inst, Sydney Eye Hosp, Sydney, NSW 2006, Australia
[2] Univ Sydney, Save Sight Inst, Glaucoma Serv, Sydney, NSW 2006, Australia
[3] Univ New S Wales, Sch Community Med, Sydney, NSW, Australia
来源
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY | 1999年 / 27卷 / 05期
关键词
glaucoma; oculokinetic perimetry;
D O I
10.1046/j.1440-1606.1999.00215.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background and Method: Oculokinetic perimetry (OKP) was performed on 98 patients (187 eyes) using the Damato 26-point glaucoma screening chart, Results were compared with those obtained from a 24-2 full threshold test on a Humphrey Field Analyser (HFA). Results: In its ability to detect pathology in individual eyes, OKP had a sensitivity of 75.0% and a specificity of 71.4%. To detect glaucoma, OKP demonstrated a sensitivity of 86.0% and a specificity of 56.1%. The number of OKP defects detected increased with increasing HFA mean defect and corrected pattern standard deviation. Whereas moderate and severe field defects were almost always detected, smaller and shallower glaucoma defects were often missed. Conclusion: The fall in sensitivity and specificity of the OKP chart in identifying milder glaucomatous field defects diminishes its value as a screening test. However, its introduction into wider use in the community may increase awareness of glaucoma amongst general practitioners and members of the public, and help to detect previously undiagnosed glaucoma with moderate to severe damage. A normal OKP finding does not exclude the presence of early glaucoma. Combined with ophthalmoscopy, OKP may improve glaucoma detection rates amongst non-ophthalmologists.
引用
收藏
页码:306 / 311
页数:6
相关论文
共 14 条
[1]  
Christoffersen T, 1995, EYE, V9, P36
[2]   OCULOKINETIC PERIMETRY FOR THE ASSESSMENT OF VISUAL-FIELDS [J].
CLARK, BJ ;
TIMMS, C ;
FRANKS, WA .
ARCHIVES OF DISEASE IN CHILDHOOD, 1990, 65 (04) :432-434
[3]  
DAMATO B E, 1989, Eye (London), V3, P727
[4]   OCULOKINETIC PERIMETRY - A SIMPLE VISUAL-FIELD TEST FOR USE IN THE COMMUNITY [J].
DAMATO, BE .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1985, 69 (12) :927-931
[5]  
DAMATO BE, 1985, T OPHTHAL SOC UK, V104, P681
[6]  
DAMATO BE, 1990, EYE, V4, P633
[7]  
GREVE M, 1993, CAN J OPHTHALMOL, V28, P201
[8]   EFFECTIVENESS OF UNSUPERVISED OCULOKINETIC PERIMETRY FOR DETECTING GLAUCOMATOUS VISUAL-FIELD DEFECTS [J].
HARPER, RA ;
HILL, AR ;
REEVES, BC .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1994, 14 (02) :199-202
[9]   Prevalence of open-angle glaucoma in Australia - The Blue Mountains eye study [J].
Mitchell, P ;
Smith, W ;
Attebo, K ;
Healey, PR .
OPHTHALMOLOGY, 1996, 103 (10) :1661-1669
[10]   CLINICAL-EVALUATION OF A MULTI-FIXATION CAMPIMETER FOR THE DETECTION OF GLAUCOMATOUS VISUAL-FIELD LOSS [J].
MUTLUKAN, E ;
DAMATO, BE ;
JAY, JL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (06) :332-338