Loop-Mediated Isothermal Amplification as Point-of-Care Diagnosis for Neglected Parasitic Infections

被引:32
|
作者
Avendano, Catalina [1 ]
Alfonso Patarroyo, Manuel [2 ,3 ]
机构
[1] Univ Ciencias Aplicadas & Ambientales UDCA, Anim Sci Fac, Bogota 111166, Colombia
[2] Fdn Inst Inmunol Colombia FIDIC, Mol Biol & Immunol Dept, Bogota 111321, Colombia
[3] Univ Rosario, Sch Med & Hlth Sci, Basic Sci Dept, Bogota 112111, Colombia
关键词
neglected parasitic infection; diagnostic test; LAMP; sensitivity; HUMAN AFRICAN TRYPANOSOMIASIS; NUCLEIC-ACID AMPLIFICATION; RAPID DETECTION; LAMP ASSAY; SAND FLIES; CUTANEOUS LEISHMANIASIS; VISCERAL LEISHMANIASIS; CLONORCHIS-SINENSIS; SCHISTOSOMA-MANSONI; SENSITIVE DETECTION;
D O I
10.3390/ijms21217981
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The World Health Organisation (WHO) has placed twenty diseases into a group known as neglected tropical diseases (NTDs), twelve of them being parasitic diseases: Chagas' disease, cysticercosis/taeniasis, echinococcosis, food-borne trematodiasis, human African trypanosomiasis (sleeping sickness), leishmaniasis, lymphatic filariasis, onchocerciasis (river blindness), schistosomiasis, soil-transmitted helminthiasis (ascariasis, hookworm, trichuriasis), guinea-worm and scabies. Such diseases affect millions of people in developing countries where one of the main problems concerning the control of these diseases is diagnosis-based due to the most affected areas usually being far from laboratories having suitable infrastructure and/or being equipped with sophisticated equipment. Advances have been made during the last two decades regarding standardising and introducing techniques enabling diagnoses to be made in remote places, i.e., the loop-mediated isothermal amplification (LAMP) technique. This technique's advantages include being able to perform it using simple equipment, diagnosis made directly in the field, low cost of each test and the technique's high specificity. Using this technique could thus contribute toward neglected parasite infection (NPI) control and eradication programmes. This review describes the advances made to date regarding LAMP tests, as it has been found that even though several studies have been conducted concerning most NPI, information is scarce for others.
引用
收藏
页码:1 / 32
页数:32
相关论文
共 50 条
  • [21] Loop-Mediated Isothermal Amplification of Trypanosoma cruzi DNA for Point-of-Care Follow-Up of Anti-Parasitic Treatment of Chagas Disease
    Munoz-Calderon, Arturo A.
    Besuschio, Susana A.
    Wong, Season
    Fernandez, Marisa
    Garcia Caceres, Lady J.
    Giorgio, Patricia
    Barcan, Laura A.
    Markham, Cole
    Liu, Yanwen E.
    Alarcon de Noya, Belkisyole
    Longhi, Silvia A.
    Schijman, Alejandro G.
    MICROORGANISMS, 2022, 10 (05)
  • [22] Loop-Mediated Isothermal Amplification-Integrated CRISPR Methods for Infectious Disease Diagnosis at Point of Care
    Yigci, Defne
    Atceken, Nazente
    Yetisen, Ali K.
    Tasoglu, Savas
    ACS OMEGA, 2023, 8 (46): : 43357 - 43373
  • [23] Diagnosis of Brugian Filariasis by Loop-Mediated Isothermal Amplification
    Poole, Catherine B.
    Tanner, Nathan A.
    Zhang, Yinhua
    Evans, Thomas C., Jr.
    Carlow, Clotilde K. S.
    PLOS NEGLECTED TROPICAL DISEASES, 2012, 6 (12):
  • [24] Loop-Mediated Isothermal Amplification for Diagnosis of Zoonotic Malaria
    Lai, Meng Yee
    Sohairi, Ainaa Nadrah
    Zen, Lee Phone Youth
    Abdullah, Mohd Lutfi
    Lau, Yee Ling
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2024, 111 (04): : 765 - 769
  • [25] Super-assembly of integrated gold magnetic assay with loop-mediated isothermal amplification for point-of-care testing
    Liang, Jianping
    Zeng, Jie
    Huang, Xiaojuan
    Zhu, Tengteng
    Gong, Yonglong
    Dong, Chen
    Wang, Xiangrong
    Zhao, Lingzhi
    Xie, Lei
    Liang, Kang
    Tan, Qiongxiang
    Cui, Yali
    Kong, Biao
    Hui, Wenli
    NANO RESEARCH, 2023, 16 (01) : 1242 - 1251
  • [26] Loop-Mediated Isothermal Amplification on Crude DNA as a Point-of-Care Test for the Diagnosis of Mycoplasma-Related Vaginitis During Early Pregnancy
    Wang, Yichao
    Zhang, Bumei
    Sun, Yan
    Liu, Yunde
    Gu, Yajun
    LABORATORY MEDICINE, 2018, 49 (01) : 59 - 67
  • [27] Loop-Mediated Isothermal Amplification for Laboratory Confirmation of Buruli Ulcer Disease-Towards a Point-of-Care Test
    Beissner, Marcus
    Phillips, Richard Odame
    Battke, Florian
    Bauer, Malkin
    Badziklou, Kossi
    Sarfo, Fred Stephen
    Maman, Issaka
    Rhomberg, Agata
    Piten, Ebekalisai
    Frimpong, Michael
    Huber, Kristina Lydia
    Symank, Dominik
    Jansson, Moritz
    Wiedemann, Franz Xaver
    Kere, Abiba Banla
    Herbinger, Karl-Heinz
    Loescher, Thomas
    Bretzel, Gisela
    PLOS NEGLECTED TROPICAL DISEASES, 2015, 9 (11):
  • [28] Loop-mediated isothermal amplification assay as a point-of-care diagnostic tool for Vibrio parahaemolyticus: recent developments and improvements
    Anupama, Karanth Padyana
    Chakraborty, Anirban
    Karunasagar, Iddya
    Karunasagar, Indrani
    Maiti, Biswajit
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2019, 19 (03) : 229 - 239
  • [29] Loop-mediated isothermal amplification (LAMP): An effective molecular point-of-care technique for the rapid diagnosis of coronavirus SARS-CoV-2
    Chaouch, Melek
    REVIEWS IN MEDICAL VIROLOGY, 2021, 31 (06)
  • [30] Point-of-Care Diagnostic Test for Rapid Detection of Infectious Laryngotracheitis Virus by Loop-Mediated Isothermal Amplification and Nanoprobes
    Cea-Callejo, Pablo
    Trenado, Claudia
    El Mansouri, Elias
    Gomez-Lucia, Esperanza
    Domenech, Ana
    Biarnes, Mar
    Cuenca, J. Marco
    Sanchez-Llatas, Christian J.
    Madrid, Ricardo
    Benitez, Laura
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2025, 26 (05)