Accuracy and precision of a novel non-invasive core thermometer

被引:84
作者
Kimberger, O. [1 ]
Thell, R. [1 ]
Schuh, M. [1 ]
Koch, J. [2 ]
Sessler, D. I. [3 ]
Kurz, A. [3 ]
机构
[1] Med Univ Vienna, Dept Anesthesiol & Gen Intens Care, A-1090 Vienna, Austria
[2] Draegerwerk AG & Co KGaA, D-23542 Lubeck, Germany
[3] Cleveland Clin, Dept Outcomes Res, Cleveland, OH 44106 USA
关键词
monitoring; temperature; body; TEMPORAL-ARTERY; TEMPERATURE-MEASUREMENTS; ANESTHESIA; AXILLARY; INFANTS; HYPERTHERMIA; RELIABILITY; AGREEMENT; CHILDREN; HUMANS;
D O I
10.1093/bja/aep134
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Accurate measurement of core temperature is a standard component of perioperative and intensive care patient management. However, core temperature measurements are difficult to obtain in awake patients. A new non-invasive thermometer has been developed, combining two sensors separated by a known thermal resistance ('double-sensor' thermometer). We thus evaluated the accuracy of the double-sensor thermometer compared with a distal oesophageal thermometer to determine if the double-sensor thermometer is a suitable substitute. In perioperative and intensive care patient populations (n=68 total), double-sensor measurements were compared with measurements from a distal oesophageal thermometer using Bland-Altman analysis and Lin's concordance correlation coefficient (CCC). Overall, 1287 measurement pairs were obtained at 5 min intervals. Ninety-eight per cent of all double-sensor values were within +/- 0.5 degrees C of oesophageal temperature. The mean bias between the methods was -0.08 degrees C; the limits of agreement were -0.66 degrees C to 0.50 degrees C. Sensitivity and specificity for detection of fever were 0.86 and 0.97, respectively. Sensitivity and specificity for detection of hypothermia were 0.77 and 0.93, respectively. Lin's CCC was 0.93. The new double-sensor thermometer is sufficiently accurate to be considered an alternative to distal oesophageal core temperature measurement, and may be particularly useful in patients undergoing regional anaesthesia.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 30 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Detecting fever in young infants: Reliability of perceived, pacifier, and temporal artery temperatures in infants younger than 3 months of age [J].
Callanan, D .
PEDIATRIC EMERGENCY CARE, 2003, 19 (04) :240-243
[3]   The accuracy and precision of body temperature monitoring methods during regional and general anesthesia [J].
Cattaneo, CG ;
Frank, SM ;
Hesel, TW ;
El-Rahmany, HK ;
Kim, LJ ;
Tran, KM .
ANESTHESIA AND ANALGESIA, 2000, 90 (04) :938-945
[4]   Malignant hyperthermia associated with exercise-induced rhabdomyolysis or congenital abnormalities and a novel RYR1 mutation in New Zealand and Australian pedigrees [J].
Davis, M ;
Brown, R ;
Dickson, A ;
Horton, H ;
James, D ;
Laing, N ;
Marston, R ;
Norgate, M ;
Perlman, D ;
Pollock, N ;
Stowell, K .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (04) :508-515
[5]  
Fox R., 1971, J PHYSL, V212, P8
[6]   Temperature monitoring practices during regional anesthesia [J].
Frank, SM ;
Nguyen, JM ;
Garcia, CM ;
Barnes, RA .
ANESTHESIA AND ANALGESIA, 1999, 88 (02) :373-377
[7]   A non-invasive device to continuously determine heat strain in humans [J].
Gunga, Hanns-Christian ;
Sandsund, Mariann ;
Reinertsen, Randi E. ;
Sattler, Frank ;
Koch, Jochim .
JOURNAL OF THERMAL BIOLOGY, 2008, 33 (05) :297-307
[8]   Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-temperature estimates by cutaneous liquid-crystal thermometers [J].
Ikeda, T ;
Sessler, DI ;
Marder, D ;
Xiong, JY .
ANESTHESIOLOGY, 1997, 86 (03) :603-612
[9]   Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population [J].
Jean-Mary, MB ;
Dizanzio, J ;
Shaw, J ;
Bernstein, HH .
JOURNAL OF PEDIATRICS, 2002, 141 (05) :671-676
[10]   Temporal artery versus bladder thermometry during Perioperative and intensive care unit monitoring [J].
Kimberger, Oliver ;
Cohen, Delphine ;
Illievich, Udo ;
Lenhardt, Rainer .
ANESTHESIA AND ANALGESIA, 2007, 105 (04) :1042-1047