Investigation of 3D diamond detector dosimetric characteristics

被引:6
|
作者
Kanxheri, K. [1 ]
Solestizi, L. Alunni [1 ]
Biasini, M. [1 ,2 ]
Caprai, M. [1 ]
Dipilato, A. C. [3 ]
Iacco, M. [4 ]
Ionica, M. [1 ]
Lagomarsino, S. [5 ,6 ]
Menichelli, M. [1 ]
Morozzi, A. [1 ,7 ]
Passeri, D. [1 ,7 ]
Sciortino, S. [5 ,6 ]
Talamonti, C. [5 ,8 ]
Zucchetti, C. [4 ]
Servoli, L. [1 ]
机构
[1] Ist Nazl Fis Nucl, Sez Perugia, Perugia, Italy
[2] Univ Perugia, Dipartimento Fis & Geol, Perugia, Italy
[3] Univ Perugia, Dipartimento Scie Chirurg & Biomed, Perugia, Italy
[4] Osped Santa Maria Misericordia, Dipartimento Fis Med, Perugia, Italy
[5] Ist Nazl Fis Nucl, Sez Firenze, Florence, Italy
[6] Univ Florence, Dipartimento Fis & Astron, Florence, Italy
[7] Univ Perugia, Dipartimento Ingn Elettron, Perugia, Italy
[8] Univ Florence, Dipartimento Sci Biomed Sperimentali & Clin Mario, Florence, Italy
来源
JOURNAL OF INSTRUMENTATION | 2018年 / 13卷
关键词
Diamond Detectors; Dosimetry concepts and apparatus; Radiotherapy concepts; SINGLE-CRYSTAL;
D O I
10.1088/1748-0221/13/06/P06006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recently, a polycrystalline chemical vapor deposited (pCVD) 3D diamond detector with graphitic in bulk electrodes, fabricated using a pulsed laser technique has been evaluated for photon beam radiation dosimetry during in-air exposure. The same 3D diamond detector, has now been investigated to evaluate its performance under clinically relevant conditions putting the detector inside a Polymethylmethacrylate (PMMA) phantom, to obtain higher precision dosimetric measurements. The detector leakage current was of the order of +/- 25 pA or less for bias voltages up to -100 V. The 3D detector was tested for time stability and repeatability showing excellent performance with less than 0.6% signal variation. It also showed a linear response for low dose rates with a deviation from linearity of 2%. It was also possible to verify the detector response as a function of the depth in PMMA up to 18 cm.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] An Investigation of the Dosimetric Characteristics of a Novel Radiochromic 3D Dosimeter
    Jackson, J.
    Juang, T.
    Adamovics, J.
    Oldham, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] A 3D diamond detector for particle tracking
    Artuso, M.
    Bachmair, F.
    Bani, L.
    Bartosik, M.
    Beacham, J.
    Bellini, V.
    Belyaev, V.
    Bentele, B.
    Berdermann, E.
    Bergonzo, P.
    Bes, A.
    Brom, J-M.
    Bruzzi, M.
    Cerv, M.
    Chau, C.
    Chiodini, G.
    Chren, D.
    Cindro, V.
    Claus, G.
    Collot, J.
    Costa, S.
    Cumalat, J.
    Dabrowski, A.
    D'Alessandro, R.
    de Boer, W.
    Dehning, B.
    Dobos, D.
    Dunser, M.
    Eremin, V.
    Eusebi, R.
    Forcolin, G.
    Forneris, J.
    Frais-Koelbl, H.
    Gan, K. K.
    Gastal, M.
    Goffe, M.
    Goldstein, J.
    Golubev, A.
    Gonella, L.
    Gorisek, A.
    Graber, L.
    Grigoriev, E.
    Grosse-Knetter, J.
    Gui, B.
    Guthoff, M.
    Haughton, I.
    Hidas, D.
    Hits, D.
    Hoeferkamp, M.
    Hofmann, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 402 - 405
  • [3] A 3D diamond detector for particle tracking
    Bachmair, F.
    Baeni, L.
    Bergonzo, P.
    Caylar, B.
    Forcolin, G.
    Haughton, I.
    Hits, D.
    Kagan, H.
    Kass, R.
    Li, L.
    Oh, A.
    Phan, S.
    Pomorski, M.
    Smith, D. S.
    Tyzhneyyi, V.
    Wallny, R.
    Whitehead, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 786 : 97 - 104
  • [4] DOSIMETRIC CHARACTERISTICS OF 3D PRINTED MATERIALS
    Jaselske, Evelina
    Adliene, Diana
    Rudzianskas, Viktoras
    Korobeinikova, Erika
    MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 52 - 55
  • [5] Evaluation of a 3D diamond detector for medical radiation dosimetry
    Kanxheri, K.
    Servoli, L.
    Oh, A.
    Sanchez, F. Munoz
    Forcolin, G. T.
    Murphy, S. A.
    Aitkenhead, A.
    Moore, C. J.
    Morozzi, A.
    Passeri, D.
    Bellini, M.
    Corsi, C.
    Lagomarsino, S.
    Sciortino, S.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [6] EVALUATION OF THE DOSIMETRIC CHARACTERISTICS OF A DIAMOND DETECTOR FOR PHOTON-BEAM MEASUREMENTS
    RUSTGI, SN
    MEDICAL PHYSICS, 1995, 22 (05) : 567 - 570
  • [7] Dosimetric characteristics of a reusable 3D radiochromic dosimetry material
    Park, Jong Min
    Park, So-Yeon
    Choi, Chang Heon
    Chun, Minsoo
    Han, Ji Hye
    Cho, Jin Dong
    Kim, Jung-in
    PLOS ONE, 2017, 12 (07):
  • [8] Dosimetric characterization of a 2D polycrystalline CVD diamond detector
    Bartoli, A.
    Cupparo, I.
    Baldi, A.
    Scaringella, M.
    Pasquini, A.
    Pallotta, S.
    Talamonti, C.
    Bruzzi, M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [9] Intercalibration of a polycrystalline 3D diamond detector for small field dosimetry
    Kanxheri, K.
    Aisa, D.
    Solestizi, L. Alunni
    Bellini, M.
    Caprai, M.
    Corsi, C.
    Dipilato, A. C.
    Iacco, M.
    Ionica, M.
    Lagomarsino, S.
    Morozzi, A.
    Moscatelli, F.
    Passeri, D.
    Sciortino, S.
    Talamonti, C.
    Zucchetti, C.
    Servoli, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 958
  • [10] Investigation of Dosimetric Characteristics of a MOSFET Detector for Clinical Electron Beams
    Dinc, Serap Catli
    Hancer, Ceren
    Demirci, Temur
    Akmansu, Muge
    GAZI MEDICAL JOURNAL, 2019, 30 (01): : 48 - 51