Comparison of Plan Quality and Delivery Time Between Volumetric Arc Therapy (RapidArc) and Gamma Knife Radiosurgery for Multiple Cranial Metastases

被引:159
作者
Thomas, Evan M. [1 ]
Popple, Richard A. [1 ]
Wu, Xingen [1 ]
Clark, Grant M. [1 ]
Markert, James M. [2 ]
Guthrie, Barton L. [2 ]
Yuan, Yu [1 ]
Dobelbower, Michael C. [1 ]
Spencer, Sharon A. [1 ]
Fiveash, John B. [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL USA
[2] Univ Alabama Birmingham, Dept Neurosurg, Birmingham, AL USA
关键词
Gamma Knife; LINAC; Multiple metastases; Plan quality; Radiosurgery; RapidArc; TrueBeam STx; Treatment efficiency; STEREOTACTIC RADIOSURGERY; PROSTATE-CANCER; PERFEXION; RADIOTHERAPY; HISTOGRAMS;
D O I
10.1227/NEU.0000000000000448
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Volumetric modulated arc therapy (VMAT) has been shown to be feasible for radiosurgical treatment of multiple cranial lesions with a single isocenter. OBJECTIVE: To investigate whether equivalent radiosurgical plan quality and reduced delivery time could be achieved in VMAT for patients with multiple intracranial targets previously treated with Gamma Knife (GK) radiosurgery. METHODS: We identified 28 GK treatments of multiple metastases. These were re-planned for multiarc and single-arc, single-isocenter VMAT (RapidArc) in Eclipse. The prescription for all targets was standardized to 18 Gy. Each plan was normalized for 100% prescription dose to 99% to 100% of target volume. Plan quality was analyzed by target conformity (Radiation Therapy Oncology Group and Paddick conformity indices [CIs]), dose falloff (area under the dose-volume histogram curve), as well as the V4.5, V9, V12, and V18 isodose volumes. Other end points included beam-on and treatment time. RESULTS: Compared with GK, multiarc VMAT improved median plan conformity (CIVMAT = 1.14, CIGK = 1.65; P < .001) with no significant difference in median dose falloff (P = .269), 12 Gy isodose volume (P = .500), or low isodose spill (P = .49). Multiarc VMAT plans were associated with markedly reduced treatment time. A predictive model of the 12 Gy isodose volume as a function of tumor number and volume was also developed. CONCLUSION: For multiple target stereotactic radiosurgery, 4-arc VMAT produced clinically equivalent conformity, dose falloff, 12 Gy isodose volume, and low isodose spill, and reduced treatment time compared with GK. Because of its similar plan quality and increased delivery efficiency, single-isocenter VMAT radiosurgery may constitute an attractive alternative to multi-isocenter radiosurgery for some patients.
引用
收藏
页码:409 / 417
页数:9
相关论文
共 21 条
[1]  
Chin R, 2008, PRINCIPLES AND PRACTICE OF CLINICAL TRIAL MEDICINE, P1, DOI 10.1016/B978-0-12-373695-6.00001-6
[2]   Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy [J].
Clark, Grant M. ;
Popple, Richard A. ;
Prendergast, Brendan M. ;
Spencer, Sharon A. ;
Thomas, Evan M. ;
Stewart, John G. ;
Guthrie, Barton L. ;
Markert, James M. ;
Fiveash, John B. .
PRACTICAL RADIATION ONCOLOGY, 2012, 2 (04) :306-313
[3]   FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES [J].
Clark, Grant M. ;
Popple, Richard A. ;
Young, P. Edward ;
Fiveash, John B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01) :296-302
[4]   Development of a model to predict permanent symptomatic postradiosurgery injury for arteriovenous malformation patients [J].
Flickinger, JC ;
Kondziolka, D ;
Lunsford, LD ;
Kassam, A ;
Phuong, LK ;
Liscak, R ;
Pollock, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (05) :1143-1148
[5]   Biological-effective versus conventional dose volume histograms correlated with late genitourinary and gastrointestinal toxicity after external beam radiotherapy for prostate cancer: a matched pair analysis [J].
Jani, AB ;
Hand, CM ;
Pelizzari, CA ;
Roeske, JC ;
Krauz, L ;
Vijayakumar, S .
BMC CANCER, 2003, 3 (1)
[6]   A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases [J].
Kang, Jun ;
Ford, Eric C. ;
Smith, Koren ;
Wong, John ;
McNutt, Todd R. .
MEDICAL PHYSICS, 2010, 37 (08) :4146-4154
[7]  
Lindquist C, 2008, NEUROSURGERY, V62, P721, DOI [10.1227/01.neu.0000316276.20586.dd, 10.1227/01.NEU.0000279989.86544.B6]
[8]   Adjuvant treatment of brain metastases [J].
Lohr, F ;
Pirzkall, A ;
Hof, H ;
Fleckenstein, K ;
Debus, J .
SEMINARS IN SURGICAL ONCOLOGY, 2001, 20 (01) :50-56
[9]  
Ma L, 2013, 2013 INT SOC RAD C J
[10]   Apparatus dependence of normal brain tissue dose in stereotactic radiosurgery for multiple brain metastases Technical note [J].
Ma, Lijun ;
Petti, Paula ;
Wang, Brian ;
Descovich, Martina ;
Chuang, Cynthia ;
Barani, Igor J. ;
Kuniwar, Sandeep ;
Shrieve, Dennis C. ;
Sahgal, Arjun ;
Larson, David A. .
JOURNAL OF NEUROSURGERY, 2011, 114 (06) :1580-1584