Remote Floating-Gate Field-Effect Transistor with 2-Dimensional Reduced Graphene Oxide Sensing Layer for Reliable Detection of SARS-CoV-2 Spike Proteins

被引:18
作者
Jang, Hyun-June [1 ,2 ]
Sui, Xiaoyu [1 ,2 ]
Zhuang, Wen [1 ]
Huang, Xiaodan [1 ]
Chen, Min [1 ]
Cai, Xiaolei [1 ]
Wang, Yale [3 ]
Ryu, Byunghoon [2 ]
Pu, Haihui [1 ,2 ]
Ankenbruck, Nicholas [1 ]
Beavis, Kathleen [4 ]
Huang, Jun [1 ]
Chen, Junhong [1 ,2 ]
机构
[1] Univ Chicago, Pritzker Sch Mol Engn, Chicago, IL 60637 USA
[2] Argonne Natl Lab, Chem Sci & Engn Div, Phys Sci & Engn Directorate, Lemont, IL 60439 USA
[3] Univ Wisconsin, Dept Mech Engn, Milwaukee, WI 53211 USA
[4] Univ Chicago, Dept Pathol, Chicago, IL 60637 USA
关键词
SARS-CoV-2; biosensor; graphene oxides; RFGFET; drift; pH detection;
D O I
10.1021/acsami.2c04969
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Despite intensive research of nanomaterials-based field-effect transistors (FETs) as a rapid diagnostic tool, it remains to be seen for FET sensors to be used for clinical applications due to a lack of stability, reliability, reproducibility, and scalability for mass production. Herein, we propose a remote floating-gate (RFG) FET configuration to eliminate device-to-device variations of twodimensional reduced graphene oxide (rGO) sensing surfaces and most of the instability at the solution interface. Also, critical mechanistic factors behind the electrochemical instability of rGO such as severe drift and hysteresis were identified through extensive studies on rGO-solution interfaces varied by rGO thickness, coverage, and reduction temperature. rGO surfaces in our RFGFET structure displayed a Nemstian response of 54 mV/pH (from pH 2 to 11) with a 90% yield (9 samples out of total 10), coefficient of variation (CV) < 3%, and a low drift rate of 2%, all of which were calculated from the absolute measurement values. As proof-of-concept, we demonstrated highly reliable, reproducible, and label-free detection of spike proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a saliva-relevant media with concentrations ranging from 500 fg/mL to 5 mu g/mL, with an R-2 value of 0.984 and CV < 3%, and a guaranteed limit of detection at a few pg/mL. Taken together, this new platform may have an immense effect on positioning FET bioelectronics in a clinical setting for detecting SARS-CoV-2.
引用
收藏
页码:24187 / 24196
页数:10
相关论文
共 29 条
  • [21] Analytical Sensitivity of the Abbott BinaxNOW COVID-19 Ag Card
    Perchetti, Garrett A.
    Huang, Meei-Li
    Mills, Margaret G.
    Jerome, Keith R.
    Greninger, Alexander L.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (03)
  • [22] EGFET-Based Sensors for Bioanalytical Applications: A Review
    Pullano, Salvatore Andrea
    Critello, Costantino Davide
    Mahbub, Ifana
    Tasneem, Nishat Tarannum
    Shamsir, Samira
    Islam, Syed Kamrul
    Greco, Marta
    Fiorillo, Antonino S.
    [J]. SENSORS, 2018, 18 (11)
  • [23] MoS2 Field-Effect Transistor for Next-Generation Label-Free Biosensors
    Sarkar, Deblina
    Liu, Wei
    Xie, Xuejun
    Anselmo, Aaron C.
    Mitragotri, Samir
    Banerjee, Kaustav
    [J]. ACS NANO, 2014, 8 (04) : 3992 - 4003
  • [24] Rapid Detection of COVID-19 Causative Virus (SARS-CoV-2) in Human Nasopharyngeal Swab Specimens Using Field-Effect Transistor-Based Biosensor
    Seo, Giwan
    Lee, Geonhee
    Kim, Mi Jeong
    Baek, Seung-Hwa
    Choi, Minsuk
    Ku, Keun Bon
    Lee, Chang-Seop
    Jun, Sangmi
    Park, Daeui
    Kim, Hong Gi
    Kim, Seong-Jun
    Lee, Jeong-O
    Kim, Bum Tae
    Park, Edmond Changkyun
    Kim, Seung Il
    [J]. ACS NANO, 2020, 14 (04) : 5135 - 5142
  • [25] Chemically Functionalised Graphene FET Biosensor for the Label-free Sensing of Exosomes
    Tsang, Deana Kwong Hong
    Lieberthal, Tyler J.
    Watts, Clare
    Dunlop, Iain E.
    Ramadan, Sami
    Hernandez, Armando E. del Rio
    Klein, Norbert
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [26] Solution-Gated Graphene Transistors for Chemical and Biological Sensors
    Yan, Feng
    Zhang, Meng
    Li, Jinhua
    [J]. ADVANCED HEALTHCARE MATERIALS, 2014, 3 (03) : 313 - 331
  • [27] Graphene segregated on Ni surfaces and transferred to insulators
    Yu, Qingkai
    Lian, Jie
    Siriponglert, Sujitra
    Li, Hao
    Chen, Yong P.
    Pei, Shin-Shem
    [J]. APPLIED PHYSICS LETTERS, 2008, 93 (11)
  • [28] COVID-19 pathophysiology: A review
    Yuki, Koichi
    Fujiogi, Miho
    Koutsogiannaki, Sophia
    [J]. CLINICAL IMMUNOLOGY, 2020, 215
  • [29] Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1
    Zamzami, Mazin A.
    Rabbani, Gulam
    Ahmad, Abrar
    Basalah, Ahmad A.
    Al-Sabban, Wesam H.
    Ahn, Saeyoung Nate
    Choudhry, Hani
    [J]. BIOELECTROCHEMISTRY, 2022, 143