Remote Floating-Gate Field-Effect Transistor with 2-Dimensional Reduced Graphene Oxide Sensing Layer for Reliable Detection of SARS-CoV-2 Spike Proteins

被引:18
作者
Jang, Hyun-June [1 ,2 ]
Sui, Xiaoyu [1 ,2 ]
Zhuang, Wen [1 ]
Huang, Xiaodan [1 ]
Chen, Min [1 ]
Cai, Xiaolei [1 ]
Wang, Yale [3 ]
Ryu, Byunghoon [2 ]
Pu, Haihui [1 ,2 ]
Ankenbruck, Nicholas [1 ]
Beavis, Kathleen [4 ]
Huang, Jun [1 ]
Chen, Junhong [1 ,2 ]
机构
[1] Univ Chicago, Pritzker Sch Mol Engn, Chicago, IL 60637 USA
[2] Argonne Natl Lab, Chem Sci & Engn Div, Phys Sci & Engn Directorate, Lemont, IL 60439 USA
[3] Univ Wisconsin, Dept Mech Engn, Milwaukee, WI 53211 USA
[4] Univ Chicago, Dept Pathol, Chicago, IL 60637 USA
关键词
SARS-CoV-2; biosensor; graphene oxides; RFGFET; drift; pH detection;
D O I
10.1021/acsami.2c04969
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Despite intensive research of nanomaterials-based field-effect transistors (FETs) as a rapid diagnostic tool, it remains to be seen for FET sensors to be used for clinical applications due to a lack of stability, reliability, reproducibility, and scalability for mass production. Herein, we propose a remote floating-gate (RFG) FET configuration to eliminate device-to-device variations of twodimensional reduced graphene oxide (rGO) sensing surfaces and most of the instability at the solution interface. Also, critical mechanistic factors behind the electrochemical instability of rGO such as severe drift and hysteresis were identified through extensive studies on rGO-solution interfaces varied by rGO thickness, coverage, and reduction temperature. rGO surfaces in our RFGFET structure displayed a Nemstian response of 54 mV/pH (from pH 2 to 11) with a 90% yield (9 samples out of total 10), coefficient of variation (CV) < 3%, and a low drift rate of 2%, all of which were calculated from the absolute measurement values. As proof-of-concept, we demonstrated highly reliable, reproducible, and label-free detection of spike proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a saliva-relevant media with concentrations ranging from 500 fg/mL to 5 mu g/mL, with an R-2 value of 0.984 and CV < 3%, and a guaranteed limit of detection at a few pg/mL. Taken together, this new platform may have an immense effect on positioning FET bioelectronics in a clinical setting for detecting SARS-CoV-2.
引用
收藏
页码:24187 / 24196
页数:10
相关论文
共 29 条
  • [1] Molecular diagnostic technologies for COVID-19: Limitations and challenges
    Afzal, Adeel
    [J]. JOURNAL OF ADVANCED RESEARCH, 2020, 26 : 149 - 159
  • [2] A Review of Carbon Nanotubes Field Effect-Based Biosensors
    Alabsi, S. S.
    Ahmed, Abdelaziz Yousif
    Dennis, J. O.
    Khir, M. H. Md
    Algamili, A. S.
    [J]. IEEE ACCESS, 2020, 8 : 69509 - 69521
  • [3] Solution-Gated Epitaxial Graphene as pH Sensor
    Ang, Priscilla Kailian
    Chen, Wei
    Wee, Andrew Thye Shen
    Loh, Kian Ping
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (44) : 14392 - +
  • [4] The SARS-COV-2 Spike Protein Binds Sialic Acids, and Enables Rapid Detection in a Lateral Flow Point of Care Diagnostic Device (vol 6, pg 2046, 2020)
    Baker, Alexander
    Richards, Sarah-Jane
    Congdon, Thomas
    Hasan, Muhammad
    Guy, Collette
    Zwetsloot, Alexander
    Gallo, Angelo
    Lewandowski, Jozef
    Stansfeld, Phillip
    Straube, Anne
    Walker, Marc
    Chessa, Simona
    Pergolizzi, Giulia
    Dedola, Simone
    Field, Robert
    Gibson, Matthew
    [J]. ACS CENTRAL SCIENCE, 2021, 7 (02) : 379 - 380
  • [5] Solution-gated transistors of two-dimensional materials for chemical and biological sensors: status and challenges
    Fan, Qin
    Wang, Lude
    Xu, Duo
    Duo, Yanhong
    Gao, Jie
    Zhang, Lei
    Wang, Xianbao
    Chen, Xiang
    Li, Jinhua
    Zhang, Han
    [J]. NANOSCALE, 2020, 12 (21) : 11364 - 11394
  • [6] Analytical Platform To Characterize Dopant Solution Concentrations, Charge Carrier Densities in Films and Interfaces, and Physical Diffusion in Polymers Utilizing Remote Field-Effect Transistors
    Fang, Hyun-June
    Wagner, Justine
    Li, Hui
    Zhang, Qingyang
    Mukhopadhyaya, Tushita
    Katz, Howard E.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2019, 141 (12) : 4861 - 4869
  • [7] Two-Dimensional-Material-Based Field-Effect Transistor Biosensor for Detecting COVID-19 Virus (SARS-CoV-2)
    Fathi-Hafshejani, Parvin
    Azam, Nurul
    Wang, Lu
    Kuroda, Marcelo A.
    Hamilton, Michael C.
    Hasim, Sahar
    Mahjouri-Samani, Masoud
    [J]. ACS NANO, 2021, 15 (07) : 11461 - 11469
  • [8] Graphene Transistors Are Insensitive to pH Changes in Solution
    Fu, Wangyang
    Nef, Cornelia
    Knopfrnacher, Oren
    Tarasov, Alexey
    Weiss, Markus
    Calame, Michel
    Schoenenberger, Christian
    [J]. NANO LETTERS, 2011, 11 (09) : 3597 - 3600
  • [9] Surface modification of polymers with 3-aminopropyltriethoxysilane as a general pretreatment for controlled wettability
    Howarter, John A.
    Youngblood, Jeffrey P.
    [J]. MACROMOLECULES, 2007, 40 (04) : 1128 - 1132
  • [10] Ultrasensitive detection of nucleic acids using deformed graphene channel field effect biosensors
    Hwang, Michael Taeyoung
    Heiranian, Mohammad
    Kim, Yerim
    You, Seungyong
    Leem, Juyoung
    Taqieddin, Amir
    Faramarzi, Vahid
    Jing, Yuhang
    Park, Insu
    van der Zande, Arend M.
    Nam, Sungwoo
    Aluru, Narayana R.
    Bashir, Rashid
    [J]. NATURE COMMUNICATIONS, 2020, 11 (01)