Study of single perfobond rib with head stud shear connectors for a composite structure

被引:8
|
作者
Deng, Wenqin [1 ]
Gu, Jiancheng [2 ]
Liu, Duo [3 ]
Hu, Jun [1 ]
Zhang, Jiandong [1 ,2 ,3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Civil Engn & Mech, Wuhan, Hubei, Peoples R China
[2] Nanjing Univ Technol, Coll Civil Engn, Nanjing, Jiangsu, Peoples R China
[3] Jiangsu Transportat Res Inst, Nanjing, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
composite materials; joints; shear; STRENGTH; BEHAVIOR;
D O I
10.1680/jmacr.18.00051
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The head stud connector and the perfobond rib connector are the most common forms of ductile and rigid shear connector, respectively, but have strengths and weaknesses. This study evaluates the behaviour of a single perfobond rib with head stud shear connector that combines the advantages of both. First, a shear resistance equation is proposed to predict the strength of the single perfobond rib with head stud shear connector based on equations for the head stud connector and the single perfobond rib shear connector. Five groups of single perfobond rib with head stud shear connectors, ten push-out test specimens in total, were used to investigate the fracture failure mode, load-slip relationship, shear capacity and ductility of the specimens. Based on the test results, the influences of the parameters of the shear connector on shear capacity are discussed. The experiments show that the single perfobond rib with head stud shear connector is superior in terms of shear resistance and ductility. Shear capacity and corresponding relative slip of the specimens increase with increasing diameter of the head stud and transverse rebar, whereas ductility decreases. The accuracy of the proposed shear-capacity equation is verified by comparison with the test results.
引用
收藏
页码:920 / 934
页数:15
相关论文
共 50 条
  • [1] Flexural behavior of different types of steel-concrete composite decks with perfobond rib or head stud shear connectors
    Shan, Yulin
    Chen, Yuli
    Zong, Zhouhong
    Liu, Lu
    Li, Jiaqi
    Li, Zhuo
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (07) : 1187 - 1208
  • [2] A PARAMETRIC STUDY OF PERFOBOND RIB SHEAR CONNECTORS
    OGUEJIOFOR, EC
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1994, 21 (04) : 614 - 625
  • [3] Shear strength study of perfobond rib connectors
    Department of Bridge Engineering, Tongji University, Shanghai 200092, China
    Harbin Gongye Daxue Xuebao, 2007, SUPPL. 2 (280-282):
  • [4] Feasibility study on triangular perfobond rib shear connectors in composite slab
    Ramasamy, Vetturayasudharsanan
    Govindan, Balaji
    MATERIALS TODAY-PROCEEDINGS, 2020, 21 : 133 - 136
  • [5] Bearing Capacity of Perfobond Rib Shear Connectors in Composite Girder Bridges
    Su, Qingtian
    Yang, Guotao
    Bradford, Mark A.
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (04)
  • [6] STUDY OF EARTH RETAINING COMPOSITE WALL STRUCTURE WITH PERFOBOND SHEAR CONNECTORS
    Taira, Yohei
    Furuichi, Kosuke
    Ichinomiya, Toshimichi
    FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 1213 - 1216
  • [7] Comparison of hysteretic performance of stubby Y-type perfobond rib and stud shear connectors
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Park, Sejun
    Jung, Chi -Young
    Choi, Jae-Gu
    ENGINEERING STRUCTURES, 2017, 147 : 114 - 124
  • [8] Research on shear strength of perfobond rib connectors
    Zhu W.
    Cui Y.
    Liu Y.
    Heng J.
    2017, Science Press (38): : 129 - 136
  • [9] Shear Behavior of Perfobond Rib Shear Connectors for Pre-fabricated Composite Bridges
    装配式组合梁桥开孔钢板连接件抗剪性能
    2018, Chang'an University (31):
  • [10] Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Lee, Do-Hoon
    Park, Jun-Seung
    Han, Oneil
    MATERIALS, 2017, 10 (11):