A sensitive determination method for trace bisphenol A in bottled water and wastewater samples: Binary solvent liquid phase microextraction-quadrupole isotope dilution-gas chromatography-mass spectrometry

被引:28
作者
Bodur, Sueleyman [1 ]
Erarpat, Sezin [1 ]
Bozyigit, Gamze Dalgic [2 ]
Chormey, Dotse Selali [1 ]
Oz, Ersoy [3 ]
Ozdogan, Nizamettin [4 ]
Bakirdere, Sezgin [1 ,5 ]
机构
[1] Yildiz Tech Univ, Fac Art & Sci, Dept Chem, TR-34220 Istanbul, Turkey
[2] Yildiz Tech Univ, Fac Civil Engn, Dept Environm Engn, TR-34220 Istanbul, Turkey
[3] Yildiz Tech Univ, Fac Arts & Sci, Dept Stat, TR-34220 Istanbul, Turkey
[4] Bulent Ecevit Univ, Inst Sci, Dept Environm Engn, TR-67100 Zonguldak, Turkey
[5] Turkish Acad Sci TUBA, Piyade Sokak 27, TR-06690 Ankara, Turkey
关键词
Bisphenol A; Quadrupole isotope dilution; Binary solvent liquid phase microextraction; Wastewater; Bottled water; Box Behnken design; BPA; REMOVAL; COMBINATION; EXTRACTION; SPECIATION; RELEASE;
D O I
10.1016/j.microc.2020.105532
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, accurate and precise methodology was established for the preconcentration and determination of bisphenol A in bottled water and wastewater samples at trace levels. A binary solvent liquid phase micro extraction (BSLPME) method was optimized to extract bisphenol A before determination by gas chromatography mass spectrometry (GC-MS). The type of binary solvent/disperser solvent, vortex period and mode of adding extraction and disperser solvent mixture to aqueous solution were determined by univariate optimization. Three significant parameters including volume of binary solvent, volume of dispersive solvent and ratio of binary solvent were optimized using Box-Behnken Design. Low limit of detection (0.30 ng/g) and limit of quantitation (0.99 ng/g) values were recorded for the BSLPME-GC-MS method. Hence, 173 times enhancement in the detection limit of the GC-MS system was achieved by the developed microextraction method. Quadrupole isotope dilution (ID4) strategy was used to augment the extraction method to achieve high accuracy and precision. When the developed BSLPME method was combined with the ID4 strategy, bottled water and wastewater samples spiked at approximately 200 ng/g recorded excellent recovery results of 100.3 +/- 0.4% and 100.0 +/- 0.5%, respectively. Therefore, accurate and precise determination of bisphenol A at trace levels was achieved by a low cost, rapid and green analytical method.
引用
收藏
页数:7
相关论文
共 46 条
[1]   Combination of Vortex-Assisted Liquid-Liquid Extraction and Air-Assisted Liquid-Liquid Microextraction for the Extraction of Bisphenol A and Bisphenol B in Canned Doogh Samples [J].
Amini, Roya ;
Khandaghi, Jalil ;
Mogaddam, Mohammad Reza Afshar .
FOOD ANALYTICAL METHODS, 2018, 11 (11) :3267-3275
[2]   Adsorptive removal of bisphenol A (BPA) from aqueous solution: A review [J].
Bhatnagar, Amit ;
Anastopoulos, Loannis .
CHEMOSPHERE, 2017, 168 :885-902
[3]   Assessment of different isotope dilution strategies and their combination with switchable solvent-based liquid phase microextraction prior to the quantification of bisphenol A at trace levels via GC-MS [J].
Bodur, Suleyman ;
Erarpat, Sezin ;
Chormey, Dotse Selali ;
Bozyigit, Gamze Dalgic ;
Oz, Ersoy ;
Ozdogan, Nizamettin ;
Bakirdere, Sezgin .
NEW JOURNAL OF CHEMISTRY, 2020, 44 (32) :13685-13691
[4]   Mercury speciation in seafood using isotope dilution analysis: A review [J].
Clemens, Stephanie ;
Monperrus, Mathilde ;
Donard, Olivier F. X. ;
Amouroux, David ;
Guerin, Thierry .
TALANTA, 2012, 89 :12-20
[5]   Micro-QuEChERS extraction coupled to GC-MS for a fast determination of Bisphenol A in human urine [J].
Correia-Sa, Luisa ;
Norberto, Sonia ;
Delerue-Matos, Cristina ;
Calhau, Conceicao ;
Domingues, Valentina F. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1072 :9-16
[6]   Aerobic granular sludge for bisphenol A (BPA) removal from wastewater [J].
Cydzik-Kwiatkowska, Agnieszka ;
Bernat, Katarzyna ;
Zielinska, Magdalena ;
Bulkowska, Katarzyna ;
Wojnowska-Baryla, Irena .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2017, 122 :1-11
[7]   Bisphenol A release from an orthodontic resin composite: A GC/MS and LC/MS study [J].
Deviot, Marc ;
Lachaise, Isabelle ;
Hoegg, Christof ;
Durner, Juergen ;
Reichl, Franz-Xaver ;
Attal, Jean-Pierre ;
Dursun, Elisabeth .
DENTAL MATERIALS, 2018, 34 (02) :341-354
[8]   Switchable solvent liquid-phase microextraction-gas chromatography-quadrupole isotope dilution mass spectrometry for the determination of 4-n-nonylphenol in municipal wastewater [J].
Erarpat, Sezin ;
Bodur, Suleyman ;
Chormey, Dotse Selali ;
Bakirdere, Sezgin .
MICROCHEMICAL JOURNAL, 2019, 144 :1-5
[9]   Removal of BPA by enzyme polymerization using NF membranes [J].
Escalona, Ivonne ;
de Grooth, Joris ;
Font, Josep ;
Nijmeijer, Kitty .
JOURNAL OF MEMBRANE SCIENCE, 2014, 468 :192-201
[10]   Determination of Some Synthetic Phenolic Antioxidants and Bisphenol A in Honey Using Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Flame Ionization Detection [J].
Farajzadeh, Mir Ali ;
Abbaspour, Maryam ;
Mogaddam, Mohammad Reza Afshar ;
Ghorbanpour, Houshang .
FOOD ANALYTICAL METHODS, 2015, 8 (08) :2035-2043