Objective: To systematically review instruments for measuring the level and effectiveness of sedation in adult and pediatric ICU patients. Study indentification: We searched MEDLINE, EMBASE, the Cochrane Library and reference lists of the relevant articles. We selected studies if the sedation instrument reported items related to consciousness and one or more additional items related to the effectiveness or side effects of sedation. Data abstraction: We extracted data on the description of the instrument and on their measurement properties (internal consistency, reliability, validity and responsiveness). Results: We identified 25 studies describing relevant sedation instruments. In addition to the level of consciousness, agitation and synchrony with the ventilator were the most frequently assessed aspects of sedation. Among the 25 instruments, one developed in pediatric ICU patients (the Comfort Scale), and 3 developed in adult ICU patients (the Ramsay scale, the Sedation-Agitation-Scale and the Motor Activity Assessment Scale), were tested for both reliability and validity. None of these instruments were tested for their ability to detect change in sedation status over time (responsiveness). Conclusion: Many instruments have been used to measure sedation effectiveness in ICU patients. However, few of them exhibit satisfactory clinimetric properties. To help clinicians assess sedation at the bedside, to aid readers critically appraise the growing number of sedation studies in the ICU literature, and to inform the design of future investigations, additional information about the measurement properties of sedation effectiveness instruments is needed.
引用
收藏
页码:275 / 285
页数:11
相关论文
共 43 条
  • [1] ADAMS HA, 1988, ANAESTHESIST, V37, P268
  • [2] ASSESSING DISTRESS IN PEDIATRIC INTENSIVE-CARE ENVIRONMENTS - THE COMFORT SCALE
    AMBUEL, B
    HAMLETT, KW
    MARX, CM
    BLUMER, JL
    [J]. JOURNAL OF PEDIATRIC PSYCHOLOGY, 1992, 17 (01) : 95 - 109
  • [3] [Anonymous], J DRUG DEV S3
  • [4] BION JF, 1987, INTENS CARE MED, V13, P215
  • [5] Brown G, 1998, Off J Can Assoc Crit Care Nurs, V9, P20
  • [6] CARRUTHERS JR, 1993, OSA PROC, V18, P2
  • [7] Comparative study of propofol versus midazolam in the sedation of critically ill patients: Results of a prospective, randomized, multicenter trial
    Chamorro, C
    deLatorre, FJ
    Montero, A
    SanchezIzquierdo, JA
    Jareno, A
    Moreno, JA
    Gonzalez, E
    Barrios, M
    Carpintero, JL
    MartinSantos, F
    Otero, B
    Ginestal, R
    [J]. CRITICAL CARE MEDICINE, 1996, 24 (06) : 932 - 939
  • [8] SEDATION AFTER CARDIAC BYPASS-SURGERY - COMPARISON OF PROPOFOL AND MIDAZOLAM IN THE PRESENCE OF A COMPUTERIZED CLOSED-LOOP ARTERIAL-PRESSURE CONTROLLER
    CHAUDHRI, S
    KENNY, GNC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1992, 68 (01) : 98 - 99
  • [9] Patient-maintained analgesia with target-controlled alfentanil infusion after cardiac surgery: a comparison with morphine PCA
    Checketts, MR
    Gilhooly, CJ
    Kenny, GNC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (06) : 748 - 751
  • [10] Use of sedatives, analgesics and neuromuscular blocking agents in Danish ICUs 1996/97 - A national survey
    Christensen, BV
    Thunedborg, LP
    [J]. INTENSIVE CARE MEDICINE, 1999, 25 (02) : 186 - 191