Evaluation of transversal and longitudinal dispersion in a flow injection system by exploiting laser induced fluorescence:: influence of flow-cell positioning

被引:3
作者
Quintella, CM [1 ]
Watanabe, YN
Lima, AMV
Korn, M
Pepe, I
Embiruçu, M
Musse, APS
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Univ Fed Bahia, Inst Fis, BR-40170290 Salvador, BA, Brazil
[3] Univ Fed Bahia, Escola Politecn, BR-40170290 Salvador, BA, Brazil
关键词
flow injection analysis; dispersion; microfluidics; solid-liquid interfacial tension; laser induced fluorescence;
D O I
10.1016/j.aca.2004.07.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully mechanized set-up was built for the experimental determination of bi-dimensional dispersion with high spatial resolution (2400 mum(2)). Gravitational and wall effects in a single stream were evaluated by using time-based sampling and a micro-flow cell. Vertical upward and downward flows as well as horizontal flows were investigated. Ethylene glycol (MEG) and Rhodamine B in MEG were used as carrier and sample solutions, respectively. Longitudinal profiles were obtained by laser induced total fluorescence (LIF) at up to 19 transversal sites and combined to generate high-resolution bi-dimensional profiles. A two frontal maxima pattern was observed for all flows. The volumetric fraction of RB shape was highly stretched for downward flow and there was high asymmetry for horizontal flow. The sensitivity of three dispersion parameters was evaluated: maximum peak value, peak half-width at half-height, and peak area. Data modeling showed that the tanks-in-series was more sensitive to wall effects, had good adjustment with only one tank for upward and horizontal flow and needed two tanks for downward flow which was attributed to the latter having higher dispersion. A black box empirical modeling described better the gravitational effect and allowed to identify a parameter sensitive to upward and downward flow as well as hinting to two inner streams within the horizontal flow. It also pointed to a wall dispersion contribution of twice that of the liquid-liquid dispersion. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:293 / 300
页数:8
相关论文
共 37 条
[1]  
Adamson A. W., 1997, PHYS CHEM SURFACES, pcap 10
[2]   Integrated conductimetric detection:: mass distribution in a dynamic sample zone inside a flow injection manifold [J].
Andrade, FJ ;
Iñon, FA ;
Tudino, MB ;
Troccoli, OE .
ANALYTICA CHIMICA ACTA, 1999, 379 (1-2) :99-106
[3]   On-line ion-exchange preconcentration in a flow injection system coupled to capillary electrophoresis for the direct determination of UV absorbing anions [J].
Arce, L ;
Kuban, P ;
Ríos, A ;
Valcárcel, M ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :39-44
[4]   SOLVENT-EXTRACTION IN CONTINUOUS-FLOW INJECTION ANALYSIS - DETERMINATION OF MOLYBDENUM IN PLANT MATERIAL [J].
BERGAMIN, H ;
MEDEIROS, JX ;
REIS, BF ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :9-16
[5]   Excitation energy transport between the ionic forms of rhodamine B in viscous solutions [J].
Bojarski, P ;
Jankowicz, A .
JOURNAL OF LUMINESCENCE, 1999, 81 (01) :21-31
[6]   Fluorescent dimers of rhodamine 6G in concentrated ethylene glycol solution [J].
Bojarski, P ;
Matczuk, A ;
Bojarski, C ;
Kawski, A ;
Kuklinski, B ;
Zurkowska, G ;
Diehl, H .
CHEMICAL PHYSICS, 1996, 210 (03) :485-499
[7]  
FOSTER T, 1948, ANN PHYS, V2, P55
[8]  
HULL RD, 1992, ANAL CHIM ACTA, V267, P1
[9]  
Hulsman M, 1997, ANAL CHIM ACTA, V346, P351, DOI 10.1016/S0003-2670(97)90077-5
[10]   EXTRACTION BASED ON FLOW-INJECTION PRINCIPLE .1. DESCRIPTION OF EXTRACTION SYSTEM [J].
KARLBERG, B ;
THELANDER, S .
ANALYTICA CHIMICA ACTA, 1978, 98 (01) :1-7