AN EXPERIMENTAL INVESTIGATION OF THE AIR-SIDE PERFORMANCE OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SLIT FINS

被引:3
作者
Kim, Nae-Hyun [1 ]
Cho, Honggi [2 ]
机构
[1] Incheon Natl Univ, Div Mech Syst Engn, Incheon, England
[2] Samsung Elect Co, Air Conditioner & Refrigerator Div, Suwon, South Korea
关键词
extended surfaces; single-phase convection; heat transfer coefficient; pressure drop; predictive correlations; FRICTION CHARACTERISTICS; AIRSIDE PERFORMANCE; CONVEX-LOUVER; PLAIN;
D O I
10.1615/JEnhHeatTransf.2015013309
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the heat transfer and friction characteristics of 5.3-mm outer-diameter slit-fin heat exchangers were experimentally investigated. Plain-fin heat exchangers having the same 5.3-mm outer-diameter tubes were also tested for comparison. Results revealed that slit-fin samples yielded higher j and f factors than plain-fin samples. As for the effect of number of tube rows, the j factor increased as the number of tube rows decreased, but the f factor was independent of this effect (except in the one-row configuration). The one-row samples yielded significantly higher f factors, especially at low Reynolds numbers. The j/f ratios for the slit fin samples were larger than those for the plain-fin samples at high Reynolds numbers. At low Reynolds numbers, in contrast, they were smaller. A new correlation was developed based on the present data.
引用
收藏
页码:67 / 88
页数:22
相关论文
共 48 条
[1]   Accounting for the effect of the heat exchanger length in the performance evaluation of compact fin and tube heat exchangers [J].
Ameel, Bernd ;
Degroote, Joris ;
T'Joen, Christophe ;
Huisseune, Henk ;
De Schampheleire, Sven ;
Vierendeels, Jan ;
De Paepe, Michel .
APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) :544-553
[2]  
[Anonymous], 1998, 98005 ESDU
[3]  
[Anonymous], 1949, REFRIGERAT ENG
[4]  
[Anonymous], 1975, 415 ASHRAE
[5]  
[Anonymous], KOREAN J AIR COND RE
[6]  
ASHRAE, 1986, 411 ASHRAE
[7]  
ASHRAE, 1987, 412 ASHRAE
[8]  
Beecher D.T., 1987, T ASHRAE, V93, P1961
[9]  
Bergles AE, 2013, J ENHANC HEAT TRANSF, V20, P1
[10]   Effect of fin pattern on the air-side performance of herringbone wavy fin-and-tube heat exchangers [J].
Chokeman, Y ;
Wongwises, S .
HEAT AND MASS TRANSFER, 2005, 41 (07) :642-650