COMPARISON BETWEEN MEASUREMENTS OBTAINED WITH THREE DIFFERENT PERINEOMETERS

被引:48
作者
Barbosa, Patricia Brentegani [1 ]
Franco, Maira Menezes [1 ]
Souza, Flaviane de Oliveira [1 ]
Antonio, Flavia Ignacio [1 ]
Montezuma, Thais [1 ]
Jorge Ferreira, Cristine Homsi [1 ]
机构
[1] Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Biomech Med & Rehabil Locomotor Apparatus, Ribeirao Preto, SP, Brazil
关键词
Physiotherapy; Pelvic floor; Evaluation; Reliability; Woman; FLOOR MUSCLE STRENGTH; VAGINAL PRESSURE MEASUREMENTS; STRESS URINARY-INCONTINENCE; PELVIC FLOOR; EXERCISE; RELIABILITY; POSITIONS;
D O I
10.1590/S1807-59322009000600007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To analyze the results obtained in the evaluation of intra-vaginal pressure using three different brands of perineometers in nulliparous volunteers. MATERIALS AND METHODS: Twenty nulliparous women with no anatomical alterations and/or dysfunction of the pelvic floor were enrolled in our study. All the women had the ability to voluntarily contract their PFM (Pelvic Floor Muscles), as assessed by digital palpation. The intra-vaginal pressure was assessed using three different brands of perineometer (Neurodyn Evolution (TM), SensuPower (TM) and Peritron (TM)). Each volunteer was evaluated on three alternate days by a single examiner using a single brand of perineometer on each day. In the assessment, the volunteers were required to pull (contract) their PFM in and up as strongly as possible 3 times and to sustain the contraction for 5 seconds, with an interval of 30 seconds between each pull. For the statistical analysis, a concordance correlation coefficient was used to compare the values that were obtained with each brand of perineometer. RESULTS: A moderate concordance (0.51) was found between the results from the Peritron (TM) and Neurodyn (TM) perineometers, a fair concordance (0.21) between the Peritron (TM) and SensuPower (TM) brands and a poor concordance (0.19) between the Neurodyn (TM) and SensuPower (TM) brands. CONCLUSION: The concordance of the measurements of the intra-vaginal pressure ranged from poor to moderate, suggesting that perineometers of different brands generate different results.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 1997, PRACTICAL STAT MED R
[2]  
[Anonymous], 2000, DESIGN ANAL EXPT
[3]  
BENVENUTI F, 1987, AM J PHYS MED REHAB, V66, P155
[4]   Does the size of the vaginal probe affect measurement of pelvic floor muscle strength? [J].
Bo, K ;
Raastad, R ;
Finckenhagen, HB .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2005, 84 (02) :129-133
[5]   Is there any difference in measurement of pelvic floor muscle strength in supine and standing position? [J].
Bo, K ;
Finckenhagen, HB .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2003, 82 (12) :1120-1124
[6]   Pelvic floor muscle strength and response to pelvic floor muscle training for stress urinary incontinence [J].
Bo, K .
NEUROUROLOGY AND URODYNAMICS, 2003, 22 (07) :654-658
[7]   PELVIC FLOOR MUSCLE EXERCISE FOR THE TREATMENT OF FEMALE STRESS URINARY-INCONTINENCE .1. RELIABILITY OF VAGINAL PRESSURE MEASUREMENTS OF PELVIC FLOOR MUSCLE STRENGTH [J].
BO, K ;
KVARSTEIN, B ;
HAGEN, R ;
LARSEN, S .
NEUROUROLOGY AND URODYNAMICS, 1990, 9 (05) :471-477
[8]   PELVIC FLOOR MUSCLE EXERCISE FOR THE TREATMENT OF FEMALE STRESS URINARY-INCONTINENCE .2. VALIDITY OF VAGINAL PRESSURE MEASUREMENTS OF PELVIC FLOOR MUSCLE STRENGTH AND THE NECESSITY OF SUPPLEMENTARY METHODS FOR CONTROL OF CORRECT CONTRACTION [J].
BO, K ;
KVARSTEIN, B ;
HAGEN, RR ;
LARSEN, S .
NEUROUROLOGY AND URODYNAMICS, 1990, 9 (05) :479-487
[9]   PRESSURE MEASUREMENTS DURING PELVIC FLOOR MUSCLE CONTRACTIONS - THE EFFECT OF DIFFERENT POSITIONS OF THE VAGINAL MEASURING DEVICE [J].
BO, K .
NEUROUROLOGY AND URODYNAMICS, 1992, 11 (02) :107-113
[10]   Vaginal palpation of pelvic floor muscle strength: inter-test reproducibility and comparison between palpation and vaginal squeeze pressure [J].
Bo, K ;
Finckenhagen, HB .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2001, 80 (10) :883-887