Corona Charged Aerosol Detector in studying retention and β-cyclodextrin complex stability using RP-HPLC

被引:0
作者
Dajic, Nevena [1 ]
Otasevic, Biljana [1 ]
Malenovic, Andelija [1 ]
Zecevic, Mira [1 ]
Holzgrabe, Ulrike [2 ]
Protic, Ana [1 ]
机构
[1] Univ Belgrade, Fac Pharm, Dept Drug Anal, Vojvode Stepe 450, Belgrade 11152, Serbia
[2] Univ Wurzburg, Inst Pharm & Food Chem, D-97074 Wurzburg, Germany
关键词
beta-Cyclodextrin; Inclusion complexes; HPLC; CAD; Stability constants; BINDING CONSTANTS; ELECTROSPRAY; ASSOCIATION;
D O I
10.1016/j.jpba.2020.113711
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Binding between cyclodextrin (CD) cavity and guest molecule in Reversed Phase High-Performance Liquid Chromatography (RP-HPLC) is dynamic process. In general, increasing CD concentration is inducing inclusion complex formation, leading to reduction of analyte's retention time. Consequently, the shortness in retention time is a measure of complex stability in HPLC. However, under certain experimental conditions, the retention of some analytes could be prolonged even when concentration of CD in the mobile phase is increased. In order to reveal the cause of this unexpected retention behavior, the present study was carried on. The model mixture consisted of risperidone, olanzapine and their related impurities, while beta-CD was selected among CDs, as in the previous study. In order to achieve fast equilibrium between free analyte and beta-CD-analyte complex, beta-CD was not added to the mobile phase, but only to the sample. Detection was performed with Corona Charged Aerosol Detector (CAD), suitable for nonchromophoric beta-CD. When analyzing olanzapine impurity B-beta-CD sample, three peaks were detected, namely free beta-CD, beta-CD-analyte complex and free analyte. The complex stability constant was calculated employing a modification of the Benesi-Hildebrandt equation and CAD has proven to be useful in complex stability constants assessment if retention of free analyte and beta-CD-analyte complex is distinguished. For all other analytes only two peaks could be detected, because free analyte and formed complex are eluting at the same retention time. Under such circumstances, the authors proposed the methodology for calculating stability constants and confirmed its applicability to studied model mixture. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 22 条
[1]   An HPLC chromatographic framework to analyze the β-cyclodextrin/solute complexation mechanism using a carbon nanotube stationary phase [J].
Aljhni, Rania ;
Andre, Claire ;
Lethier, Lydie ;
Guillaume, Yves Claude .
TALANTA, 2015, 144 :226-232
[2]   Charged aerosol detection in pharmaceutical analysis [J].
Almeling, Stefan ;
Ilko, David ;
Holzgrabe, Ulrike .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 69 :50-63
[3]  
[Anonymous], 2018, ANAL BIOANAL CHEM
[4]   Review: A History of Cyclodextrins [J].
Crini, Gregorio .
CHEMICAL REVIEWS, 2014, 114 (21) :10940-10975
[5]   Cyclodextrins and their uses: a review [J].
Del Valle, EMM .
PROCESS BIOCHEMISTRY, 2004, 39 (09) :1033-1046
[6]   Efficient determination and evaluation of model cyclodextrin complex binding constants by electrospray mass spectrometry [J].
Dotsikas, Y ;
Loukas, YL .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) :1123-1129
[7]   On the specificity of cyclodextrin complexes detected by electrospray mass spectrometry [J].
Gabelica, V ;
Galic, N ;
De Pauw, E .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (08) :946-953
[8]  
Guo M., 2000, J MASS SPECTROM, V39, P594
[9]   Studies on the non-covalent complexes between oleanolic acid and cyclodextrins using electrospray ionization tandem mass spectrometry [J].
Guo, MQ ;
Zhang, SQ ;
Song, FR ;
Wang, DW ;
Liu, ZQ ;
Liu, SY .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (07) :723-731
[10]   An Efficient and Secure Certificateless Authentication Protocol for Healthcare System on Wireless Medical Sensor Networks [J].
Guo, Rui ;
Wen, Qiaoyan ;
Jin, Zhengping ;
Zhang, Hua .
SCIENTIFIC WORLD JOURNAL, 2013,