Loss Investigation of Interior Permanent-Magnet Motors Considering Carrier Harmonics and Magnet Eddy Currents

被引:179
作者
Yamazaki, Katsumi [1 ]
Abe, Atsushi [1 ]
机构
[1] Chiba Inst Technol, Dept Elect Elect & Comp Engn, Chiba 2750016, Japan
关键词
Carrier harmonics; finite-element analysis; interior permanent-magnet synchronous motor; iron loss; pulsewidth-modulated (PWM) inverter;
D O I
10.1109/TIA.2009.2013550
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, we investigate losses of interior permanent-magnet motors driven by pulsewidth-modulated inverters using 3-D finite-element analysis, which can estimate the eddy-current loss in the permanent magnet accurately. The calculated losses are compared with the measured results and the theoretical solution to verify the validity of the analysis. The variation of the magnet eddy-current loss due to the division of the magnet is also investigated. It is clarified that the eddy-current loss in the permanent magnet is mainly produced by the carrier harmonies of the inverter and that the axial length of the divided magnet should be smaller than the skin depth of the eddy currents produced by the major harmonies for the loss reduction.
引用
收藏
页码:659 / 665
页数:7
相关论文
共 5 条
[2]   CORE LOSS IN BURIED MAGNET PERMANENT-MAGNET SYNCHRONOUS MOTORS [J].
SCHIFERL, R ;
LIPO, TA .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1989, 4 (02) :279-284
[3]   FIELD WEAKENING IN BURIED PERMANENT-MAGNET AC MOTOR-DRIVES [J].
SNEYERS, B ;
NOVOTNY, DW ;
LIPO, TA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (02) :398-407
[4]  
WAKAO S, 2005, JOINT TECH M STAT AP, P83
[5]   Iron loss analysis of interior fermanent-magnet synchronous motors - Variation of main loss factors due to driving condition [J].
Yamazaki, Katsumi ;
Seto, Yoshiaki .