Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty

被引:83
作者
Bäthis, H
Perlick, L
Tingart, M
Lüring, C
Perlick, C
Grifka, J
机构
[1] Univ Regensburg, Dept Orthopaed Surg, D-93042 Regensburg, Germany
[2] Aarhus Univ Hosp, Aarhus Kommune Hosp, Dept Orthopaed, DK-8000 Aarhus C, Denmark
关键词
D O I
10.1007/s00264-003-0533-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Restoration of the mechanical limb axis and accurate component orientation are two major factors affecting the long-term results after total knee replacement (TKR). Different navigation systems are available to improve the outcome. Image-based systems require preoperative CT scans, while non-image-based systems gain all necessary information intra-operatively during a registration process. We studied 130 patients who received a TKR either using the CT-based (Knee 1.1) or the CT-free module (CT-free Knee 1.0) of the BrainLAB Vector-Vision Navigation System. Post-operative leg alignment and component orientation was determined on long-leg coronal and lateral X-rays. Sixty of 65 patients in the CT-based group and 63/65 patients in the CT-free group had a post-operative leg axis between 3degrees varus/valgus. No significant differences were found for varus/valgus orientation of the femoral and tibial components.
引用
收藏
页码:87 / 90
页数:4
相关论文
共 17 条
  • [1] BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
  • [2] DELP SL, 1998, CLIN ORTHOP RELAT R, V354, P49
  • [3] TOTAL CONDYLAR KNEE ARTHROPLASTY - PROSTHETIC COMPONENT POSITIONING AND RADIOLUCENT LINES
    HVID, I
    NIELSEN, S
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02): : 160 - 165
  • [4] CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT
    JEFFERY, RS
    MORRIS, RW
    DENHAM, RA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05): : 709 - 714
  • [5] JENNY JY, 2003, P 70 ANN M AAOS AM A, P96
  • [6] Instrumentation pitfalls - You just can't go on autopilot!
    Laskin, RS
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (03) : 18 - 22
  • [7] INFLUENCE OF POSITIONING OF PROSTHESIS IN TOTAL KNEE REPLACEMENT
    LOTKE, PA
    ECKER, ML
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (01) : 77 - 79
  • [8] The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties
    Mahaluxmivala, J
    Bankes, MJK
    Nicolai, P
    Aldam, CH
    Allen, PW
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (05) : 635 - 640
  • [9] Navigation in knee arthroplasty - Preliminary clinical experience and prospective comparative study in comparison with conventional technique
    Mielke, RK
    Clemens, U
    Lens, JH
    Kershally, S
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (02): : 109 - 116
  • [10] Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty
    Novotny, J
    Gonzalez, MH
    Amirouche, FML
    Li, YC
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (05) : 641 - 647