Low b-value (50-100) diffusion-weighted images detect significantly more hyperintense liver lesions in children than T2-weighted images

被引:9
作者
Grasparil, Angelo Don I. I. [1 ]
Gupta, Hemali [1 ]
Sheybani, Elizabeth [1 ]
Chavhan, Govind B. [1 ,2 ]
机构
[1] Hosp Sick Children, Dept Diagnost Imaging, 555 Univ Ave, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
关键词
B-value; Children; Diffusion-weighted imaging; Liver; Magnetic resonance imaging; Neoplasm; T2-weighted fast spin echo; SPIN-ECHO; STANDARD; METASTASES; MRI;
D O I
10.1007/s00247-019-04455-9
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Low b-value (50-100 s/mm(2)) diffusion-weighted images (low b-value DWI) have been shown to be superior to T2-weighted fast spin echo sequence (T2-W) in detecting liver lesions in adults. There are no such studies assessing this difference in children. Objective The purpose of the study was to compare the sensitivity of low b-value DWI images and T2-W images in detecting focal liver lesions in children. Materials and methods A retrospective review of liver magnetic resonance imaging (MRI) to assess focal liver lesions in 50 children (22 males, 28 females; age: 2 months to 17 years [mean: 10.9 years]) was performed. Two radiologists reviewed both low b-value DWI and T2-W sequences independently on different occasions to note lesions, the smallest lesion size and the location. A consensus reading of the entire MRI examination and a correlation with follow-up, other imaging modalities and pathology in available cases were used to determine the final number of lesions as a reference standard. The average number of lesions per patient detected by both readers on each sequence was compared with each other and with the reference standard using the signed-rank test. The smallest lesions detected by each sequence were compared using the paired t-test. Results One hundred seventy hyperintense lesions were identified on consensus review to serve as the reference standard. The average number of lesions identified by both readers on low b-value DWI was 134 (79%) and on T2-W was 95 (56%). There was excellent interobserver agreement for detection of lesions on low b-value DWI (intraclass correlation coefficient [ICC]=0.96 [0.93-0.98]) and T2-W (ICC=0.85 [0.75-0.91]), with slightly better agreement on low b-value DWI. Both readers identified significantly more number of lesions on low b-value DWI compared to T2-W (Reader 1: P=0.0036, Reader 2: P=0.0001). Compared to the reference standard (mean number of lesions: 3.45), T2-W detected significantly fewer lesions (mean number of lesions: 1.91; P=0.0001) while there was no significant difference in lesion detection on low b-value DWI (mean number of lesions: 2.68; P=0.1527). Low b-value DWI and T2-W were not significantly different in identifying the smallest lesion size (Reader 1: P=0.19, Reader 2: P=0.47). Conclusion Low b-value DWI images are more sensitive than T2-W sequences in detecting hyperintense focal liver lesions in children.
引用
收藏
页码:1299 / 1305
页数:7
相关论文
共 10 条
[1]   Solitary liver lesions in children: interobserver agreement and accuracy of MRI diagnosis [J].
Alqatie, Ahmad ;
Mann, Erika ;
Moineddin, Rahim ;
Kamath, Binitha M. ;
Chavhan, Govind B. .
CLINICAL IMAGING, 2015, 39 (03) :442-448
[2]   Diagnosis of Hepatic Metastasis: Comparison of Respiration-Triggered Diffusion-Weighted Echo-Planar MRI and Five T2-Weighted Turbo Spin-Echo Sequences [J].
Bruegel, Melanie ;
Gaa, Jochen ;
Waldt, Simone ;
Woertler, Klaus ;
Holzapfel, Konstantin ;
Kiefer, Berthold ;
Rummeny, Ernst J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) :1421-1429
[3]   Liver MR Imaging in Children: Current Concepts and Technique [J].
Chavhan, Govind B. ;
Shelmerdine, Susan ;
Jhaveri, Kartik ;
Babyn, Paul S. .
RADIOGRAPHICS, 2016, 36 (05) :1517-1532
[4]   Diffusion-weighted imaging in pediatric body magnetic resonance imaging [J].
Chavhan, Govind B. ;
Caro-Dominguez, Pablo .
PEDIATRIC RADIOLOGY, 2016, 46 (06) :847-857
[5]   Diffusion-weighted Imaging in Pediatric Body MR Imaging: Principles, Technique, and Emerging Applications [J].
Chavhan, Govind B. ;
AlSabban, Zehour ;
Babyn, Paul S. .
RADIOGRAPHICS, 2014, 34 (03) :E74-+
[6]   High Sensitivity of Diffusion-weighted MR Imaging for the Detection of Liver Metastases from Neuroendocrine Tumors: Comparison with T2-weighted and Dynamic Gadolinium-enhanced MR Imaging [J].
d'Assignies, Gaspard ;
Fina, Priscilla ;
Bruno, Onorina ;
Vullierme, Marie-Pierre ;
Tubach, Florence ;
Paradis, Valerie ;
Sauvanet, Alain ;
Ruszniewski, Philippe ;
Vilgrain, Valerie .
RADIOLOGY, 2013, 268 (02) :390-399
[7]   Focal liver lesion detection and characterization with diffusion-weighted MR imaging: Comparison with standard breath-hold T2-weighted imaging [J].
Parikh, Tejas ;
Drew, Stephen J. ;
Lee, Vivian S. ;
Wong, Samson ;
Hecht, Elizabeth M. ;
Babb, James S. ;
Taouli, Bachir .
RADIOLOGY, 2008, 246 (03) :812-822
[8]   Preoperative detection of hepatic metastases: Comparison of diffusion-weighted, T2-weighted fast spin echo and gadolinium-enhanced MR imaging using surgical and histopathologic findings as standard of reference [J].
Soyer, Philippe ;
Boudiaf, Mourad ;
Place, Vinciane ;
Sirol, Marc ;
Pautrat, Karine ;
Vignaud, Alexandre ;
Staub, Fabrice ;
Tiah, Djamel ;
Hamzi, Lounis ;
Duchat, Florent ;
Fargeaudou, Yann ;
Pocard, Marc .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) :245-252
[9]   The detection and discrimination of malignant and benign focal hepatic lesions: T2 weighted vs diffusion-weighted MRI [J].
Yang, D. M. ;
Jahng, G. H. ;
Kim, H. C. ;
Jin, W. ;
Ryu, C. W. ;
Nam, D. H. ;
Lee, Y. K. ;
Park, S. Y. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1000) :319-326
[10]   Black-blood diffusion-weighted EPI acquisition of the liver with parallel imaging - Comparison with a standard T2-weighted sequence for detection of focal liver lesions [J].
Zech, Christoph J. ;
Herrmann, Karin A. ;
Dietrich, Olaf ;
Horger, Wilhelm ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
INVESTIGATIVE RADIOLOGY, 2008, 43 (04) :261-266