Methods for measuring fluoroscopic skin dose

被引:71
作者
Balter, Stephen
机构
[1] Columbia Univ, Med Ctr, Dept Med, New York, NY 10032 USA
[2] Columbia Univ, Med Ctr, Dept Radiol, New York, NY 10032 USA
关键词
fluoroscopic skin dose; interventional radiography;
D O I
10.1007/s00247-006-0193-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
This paper briefly reviews available technologies for measuring or estimating patient skin dose in the interventional fluoroscopic environment.
引用
收藏
页码:136 / 140
页数:5
相关论文
共 10 条
[1]   Radiation doses in interventional radiology procedures: The RAD-IR study Part III: Dosimetric performance of the interventional fluoroscopy units [J].
Balter, S ;
Schueler, BA ;
Miller, DL ;
Cole, PE ;
Lu, HT ;
Berenstein, A ;
Albert, R ;
Georgia, JD ;
Noonan, PT ;
Russell, EJ ;
Malisch, TW ;
Vogelzang, RL ;
Geisinger, M ;
Cardella, JF ;
St George, J ;
Miller, GL ;
Anderson, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (09) :919-926
[2]   Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures [J].
Cusma, JT ;
Bell, MR ;
Wondrow, MA ;
Taubel, JP ;
Holmes, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) :427-435
[3]   Real-time quantification and display of skin radiation during coronary angiography and intervention [J].
den Boer, A ;
de Feijter, PJ ;
Serruys, PW ;
Roelandt, JRTC .
CIRCULATION, 2001, 104 (15) :1779-1784
[4]   Evaluation of an on-line patient exposure meter in neuroradiology [J].
Gkanatsios, NA ;
Huda, W ;
Peters, KR ;
Freeman, JA .
RADIOLOGY, 1997, 203 (03) :837-842
[5]  
*INT EL COMM, 2000, 60601 IEC 2
[6]   Entrance skin dose estimates derived from dose-area product measurements in interventional radiological procedures [J].
McParland, BJ .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (852) :1288-1295
[7]   Radiation doses in interventional radiology procedures: The RAD-IR Study - Part I: Overall measures of dose [J].
Miller, DL ;
Balter, S ;
Cole, PE ;
Lu, HT ;
Schueler, BA ;
Geisinger, M ;
Berenstein, A ;
Albert, R ;
Georgia, JD ;
Noonan, PT ;
Cardella, JF ;
George, JS ;
Russell, EJ ;
Malisch, TW ;
Vogelzang, RL ;
Miller, GL ;
Anderson, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (06) :711-727
[8]  
Miller DL, 2003, J VASC INTERV RADIOL, V14, P977
[9]   Correlation of patient skin doses in cardiac interventional radiology with dose-area product [J].
van de Putte, S ;
Verhaegen, F ;
Taeymans, Y ;
Thierens, H .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (869) :504-513
[10]   Skin dose and dose-area product values for interventional cardiology procedures [J].
Vano, E ;
Gonzalez, L ;
Ten, JI ;
Fernandez, JM ;
Guibelalde, E ;
Macaya, C .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (877) :48-55