Organic-inorganic hybrid sol-gel membranes for pH sensing in highly alkaline environment

被引:3
作者
Ferreira, Barbara [1 ]
Sousa, Sara [1 ]
Sousa, Rui P. C. L. [1 ]
Costa, Susana P. G. [1 ]
Raposo, M. Manuela M. [1 ]
Parpot, Pier [1 ]
Valente, Artur J. M. [2 ]
Pereira, Rui F. P. [1 ]
Figueira, Rita B. [1 ]
机构
[1] Univ Minho, Ctr Chem, Campus Gualtar, P-4710057 Braga, Portugal
[2] Univ Coimbra, Ctr Chem, Dept Chem, P-3004535 Coimbra, Portugal
关键词
Sol-gel; Organic-inorganic hybrids; Phenolphthalein; Membranes; Sensors; CORROSION PROTECTION; GALVANIZED STEEL; CRACK DETECTION; CONCRETE; SENSOR; TEMPERATURE; COATINGS; MATRIX; DYES;
D O I
10.1016/j.conbuildmat.2022.129493
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work reports the synthesis of organic-inorganic hybrid (OIH) membranes for potential optical fibre sensors (OFS) functionalisation for pH monitoring of concrete and reinforced concrete structures (RCS). As precursors, 3-glycidyloxypropyltrimethoxysilane and Jeffamine (R) THF-170 were used. The OIH sol-gel materials were doped with phenolphthalein (phph) for pH sensing proposes and cetyl trimethyl ammonium bromide as surfactant. OIH membranes with pH sensing ability properties were successfully obtained. The dielectric properties of the resultant membranes were determined by electrochemical impedance spectroscopy. The logarithm of resistance obtained was 10.19 Omega cm(2) for the undoped matrix and, 7.06 Omega cm(2) for the doped one with phph. The results obtained in simulated concrete pore solutions, for the OIH produced, showed to be promising for application in fresh concrete. The transmittance of the synthesized OIH materials decreased after the doping with phph. The matrix showed intrinsic fluorescence and doping it only led to small deviations in the wavelength of the peak of maximum emission. Regarding thermal analysis, no significant changes were obtained on the thermal profile of the doped and undoped OIH membranes. The pH variation was detected by the OIH membrane colour change. Stability studies regarding the release of phph from the OIH matrix led to a mean dissolution time equal to 75.4 (+/- 0.02) hours, indicating that the proposed system reveals long-term stability.
引用
收藏
页数:10
相关论文
共 65 条
[1]   Corrosion rate monitoring in the laboratory and on-site [J].
Andrade, C ;
Alonso, C .
CONSTRUCTION AND BUILDING MATERIALS, 1996, 10 (05) :315-328
[2]   Evaluation of the degree of carbonation of concretes in three environments [J].
Andrade, C. .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 230
[3]  
[Anonymous], 2006, AM CANC SOC
[4]   Influence of cement type and temperature on the rate of corrosion of steel in concrete exposed to carbonation [J].
Baccay, M. A. ;
Otsuki, N. ;
Nishida, T. ;
Maruyama, S. .
CORROSION, 2006, 62 (09) :811-821
[5]   Embedded Distributed Optical Fiber Sensors in Reinforced Concrete Structures-A Case Study [J].
Barrias, Antonio ;
Casas, Joan R. ;
Villalba, Sergi .
SENSORS, 2018, 18 (04)
[6]   Fibre optic ratiometric fluorescence pH sensor for monitoring corrosion in concrete [J].
Bartelmess, Juergen ;
Zimmek, David ;
Bartholmai, Matthias ;
Strangfeld, Christoph ;
Schaeferling, Michael .
ANALYST, 2020, 145 (06) :2111-2117
[7]  
Basheer PAM, 2004, P SOC PHOTO-OPT INS, V5586, P144
[8]   Optimization of the intensity of luminescence emission from silica/poly(ethylene oxide) and silica/poly(propylene oxide) nanocomposite gels [J].
Bekiari, V ;
Lianos, P ;
Stangar, UL ;
Orel, B ;
Judeinstein, P .
CHEMISTRY OF MATERIALS, 2000, 12 (10) :3095-3099
[9]  
BERTOLINI L., 2005, CORROSION STEEL CONC
[10]   Steel corrosion and service life of reinforced concrete structures [J].
Bertolini, Luca .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2008, 4 (02) :123-137