Evaluation of Five Decontamination Methods for Filtering Facepiece Respirators

被引:272
作者
Viscusi, Dennis J. [1 ]
Bergman, Michael S. [2 ]
Eimer, Benjamin C. [2 ]
Shaffer, Ronald E. [1 ]
机构
[1] Natl Personal Protect Technol Lab, Natl Inst Occupat Safety & Hlth, Pittsburgh, PA 15236 USA
[2] EG&G Tech Serv Inc, Pittsburgh, PA 15236 USA
关键词
decontamination; filtering facepiece respirator; healthcare workers; N95; respirator; pandemic influenza; respirator reuse; WASTE-WATER DISINFECTION; HYPOCHLORITE; TECHNOLOGIES; IRRADIATION; DERMATITIS; BRONCHITIS; PARTICLES; ASTHMA; VIRUS; SKIN;
D O I
10.1093/annhyg/mep070
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Concerns have been raised regarding the availability of National Institute for Occupational Safety and Health (NIOSH)-certified N95 filtering facepiece respirators (FFRs) during an influenza pandemic. One possible strategy to mitigate a respirator shortage is to reuse FFRs following a biological decontamination process to render infectious material on the FFR inactive. However, little data exist on the effects of decontamination methods on respirator integrity and performance. This study evaluated five decontamination methods [ultraviolet germicidal irradiation (UVGI), ethylene oxide, vaporized hydrogen peroxide (VHP), microwave oven irradiation, and bleach] using nine models of NIOSH-certified respirators (three models each of N95 FFRs, surgical N95 respirators, and P100 FFRs) to determine which methods should be considered for future research studies. Following treatment by each decontamination method, the FFRs were evaluated for changes in physical appearance, odor, and laboratory performance (filter aerosol penetration and filter airflow resistance). Additional experiments (dry heat laboratory oven exposures, off-gassing, and FFR hydrophobicity) were subsequently conducted to better understand material properties and possible health risks to the respirator user following decontamination. However, this study did not assess the efficiency of the decontamination methods to inactivate viable microorganisms. Microwave oven irradiation melted samples from two FFR models. The remainder of the FFR samples that had been decontaminated had expected levels of filter aerosol penetration and filter airflow resistance. The scent of bleach remained noticeable following overnight drying and low levels of chlorine gas were found to off-gas from bleach-decontaminated FFRs when rehydrated with deionized water. UVGI, ethylene oxide (EtO), and VHP were found to be the most promising decontamination methods; however, concerns remain about the throughput capabilities for EtO and VHP. Further research is needed before any specific decontamination methods can be recommended.
引用
收藏
页码:815 / 827
页数:13
相关论文
共 34 条
[1]  
*3M INC, 2007, 3M STER VAC ETH OX S
[2]  
*ADV STER PROD, 2007, STERRAD 100S
[3]  
ANGEHRN M, 1984, AQUA, V2, P109
[4]  
[Anonymous], 1994, MMWR Recomm Rep, V43, P1
[5]  
Bailar JC., 2006, Reusability of Facemasks during an Influenza Pandemic
[6]  
Block SS., 1991, DISINFECTION STERILI, P344
[7]  
CDC, 2007, GUID IS PREC PREV TR
[8]   Inactivation of Cryptosporidium parvum oocysts using medium- and low-pressure ultraviolet radiation [J].
Craik, SA ;
Weldon, D ;
Finch, GR ;
Bolton, JR ;
Belosevic, M .
WATER RESEARCH, 2001, 35 (06) :1387-1398
[9]   Microwave or autoclave treatments destroy the infectivity of infectious bronchitis virus and avian pneumovirus but allow detection by reverse transcriptase-polymerase chain reaction [J].
Elhafi, G ;
Naylor, CJ ;
Savage, CE ;
Jones, RC .
AVIAN PATHOLOGY, 2004, 33 (03) :303-306
[10]   SODIUM-HYPOCHLORITE DERMATITIS [J].
EUN, HC ;
LEE, AY ;
LEE, YS .
CONTACT DERMATITIS, 1984, 11 (01) :45-45