Analysis of double-stranded DNA by capillary electrophoresis using poly(ethylene oxide) in the presence of hexadecyltrimethylammonium bromide

被引:12
作者
Lin, Yang-Wei [1 ]
Chang, Huan-Tsung [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem, Taipei 10764, Taiwan
关键词
DNA separation; hexadecyltrimethylammonium bromide; stacking; capillary electrophoresis; laser-induced fluorescence;
D O I
10.1016/j.chroma.2006.03.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The impact of hexadecyltrimethylammonium bromide (CTAB) on the separation of ds-DNA by capillary electrophoresis in conjunction with laser-induced fluorescence (CE-LIF) detection using poly(ethylene oxide) (PEO) solution is described. The use of CTAB for improved separation reproducibility and efficiency of DNA has not been demonstrated although it is widely used for controlling the magnitude and direction of electroosmotic flow in CE. With increasing CTAB concentration, the interactions of DNA with ethidium bromide (EtBr) and with the capillary wall decrease. For the separation of DNA fragments with the sizes ranging from several base pairs (bp) to 2176 bp, a polymer solution consisting of 0.75% poly(ethylene oxide), 100 mM TB buffer (pH 8.0), 25 mu g/mL EtBr, and 0.36 mu g/mL CTAB is proper. Using the PEO solution, we separated a mixture of DNA markers V (pBR 322/HaeIII digest) and VI (pBR 328/BglI digest and pBR 328/HinfI digest) within 8 min at -375 V/cm, with the limit of detection of 2.0 ng/mL based on the peak height for the 18-bp DNA fragment. The method is highly efficient (> 10(6) plate/m), repeatable (RSD of the migration times < 1.5%), and sensitive. In addition, it is convenient to fill a capillary (75 mu m in diameter) with such a low-viscosity PEO solution by syringe pushing. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 48 条
[1]   Analysis of oligonucleotides by on-column transient capillary isotachophoresis and capillary electrophoresis in poly(ethylene glycol)-filled columns [J].
Auriola, S ;
Jaaskelainen, I ;
Regina, M ;
Urtti, A .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3907-3911
[2]   Preconcentration and separation of antisense oligonucleotides by on-column isotachophoresis and capillary electrophoresis in polymer-filled capillaries [J].
Barmé, I ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ELECTROPHORESIS, 1998, 19 (8-9) :1445-1451
[3]   Characterization of surfactant coatings in capillary electrophoresis by atomic force microscopy [J].
Baryla, NE ;
Melanson, JE ;
McDermott, MT ;
Lucy, CA .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :4558-4565
[4]   INFLUENCE OF POLYMERS ON THE MICELLIZATION OF CETYLTRIMETHYLAMMONIUM SALTS [J].
BRACKMAN, JC ;
ENGBERTS, JBFN .
LANGMUIR, 1991, 7 (10) :2097-2102
[5]   POLY(ETHYLENEOXIDE) FOR HIGH-RESOLUTION AND HIGH-SPEED SEPARATION OF DNA BY CAPILLARY ELECTROPHORESIS [J].
CHANG, HT ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 669 (01) :113-123
[6]   Electrophoretic separation of small DNA fragments in the presence of electroosmotic flow using poly(ethylene oxide) solutions [J].
Chen, HS ;
Chang, HT .
ANALYTICAL CHEMISTRY, 1999, 71 (10) :2033-2036
[7]  
Chiari M, 2000, ELECTROPHORESIS, V21, P909, DOI 10.1002/(SICI)1522-2683(20000301)21:5<909::AID-ELPS909>3.0.CO
[8]  
2-L
[9]   Separation of double-stranded DNA fragments by capillary electrophoresis: Impacts of poly(ethylene oxide), gold nanoparticles, ethidium bromide, and pH [J].
Chiou, SH ;
Huang, MF ;
Chang, HT .
ELECTROPHORESIS, 2004, 25 (14) :2186-2192
[10]   Comparison of the separation of large DNA fragments in the presence and absence of electroosmotic flow at high pH [J].
Chiu, TC ;
Chang, HT .
JOURNAL OF CHROMATOGRAPHY A, 2002, 979 (1-2) :299-306