Effect of exposure time on in vitro caries diagnosis using the Digora(R) system

被引:24
作者
Huysmans, MCDNJM
Hintze, H
Wenzel, A
机构
[1] UNIV NIJMEGEN, DEPT CARIOL & ENDODONTOL, INST DENT CLIN RES, TRIKON, NIJMEGEN, NETHERLANDS
[2] AARHUS UNIV, ROYAL DENT COLL, DEPT ORAL RADIOL, AARHUS, DENMARK
关键词
radiography; digital radiography; diagnosis; dental caries;
D O I
10.1111/j.1600-0722.1997.tb00175.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine the in vitro diagnostic performance for approximal caries and occlusal dentine caries diagnosis of the Digora(R) system for digital radiography in relation to the exposure time. Radiographs were made of 220 extracted human posterior teeth and cuspids at exposure time levels of 3%, 6%, 10%, 20%, and 78% of the exposure time needed for E-speed film (image sets I, II, III, IV, and V, respectively). The image sets were put in random order (III, I, IV, II, V) and assessed independently by 3 observers using a 5-point confidence scale. True caries status was determined histologically after sectioning of the teeth. Evaluated parameters were: interexaminer kappa, sensitivity, specificity, D-z3/4(the distance of one operating point to the diagonal in the ROC domain) and area under the ROC curve. The Spearman correlation coefficients between the parameters and both exposure time and order of viewing of the sets were calculated. For approximal surfaces, the ranges of mean parameter values were: sensitivity 26-33%, specificity 93-95%, D(z3/4)0.63-0.84, area 0.61-0.69. For occlusal surfaces, the ranges were: sensitivity 52-60%, specificity 91-95%, D(z3/4)1.03-1.34, area 0.79-0.87. Out of 24 pairwise comparisons between sets V and I, 5 were significant. Out of 24 comparisons between set V and II, only 2 were significant. It was concluded that diagnostic performance is unlikely to be impaired for an exposure time as short as 6% of E-speed him exposure. When reducing the exposure time to 3% of E-speed film exposure, caries diagnosis may be impaired.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 15 条
[1]   On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems [J].
Borg, E ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) :82-88
[2]  
Borg E, 1996, ENDOD DENT TRAUMATOL, V12, P20
[3]  
CHANVANCE M, 1992, REV EPIDEMIOLO SANTE, V40, P209
[4]  
GRONDAHL HG, 1996, IN PRESS DENTAL UPDA
[5]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[6]   PERFORMANCE OF DIAGNOSTIC SYSTEMS IN OCCLUSAL CARIES DETECTION COMPARED [J].
LE, YL ;
VERDONSCHOT, EH .
COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1994, 22 (03) :187-191
[7]   BASIC PRINCIPLES OF ROC ANALYSIS [J].
METZ, CE .
SEMINARS IN NUCLEAR MEDICINE, 1978, 8 (04) :283-298
[8]  
Sanderink G C, 1993, Int Dent J, V43, P335
[9]   EXPOSURE PARAMETERS AND THEIR EFFECTS ON DIAGNOSTIC-ACCURACY [J].
SVENSON, B ;
WELANDER, U ;
ANNEROTH, G ;
SODERFELDT, B .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (04) :544-550
[10]   RADIOGRAPHIC DETECTABILITY OF PERIODONTAL-DISEASES - A COMPARISON OF PERIAPICAL RADIOGRAPHY WITH DETAILED ZONOGRAPHY [J].
TAMMISALO, T ;
LUOSTARINEN, T ;
VAHATALO, K ;
ROSBERG, J ;
TAMMISALO, EH .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (03) :185-190