Effect of frame design on the fracture strength of a zirconia crown and porcelain faced crown

被引:6
作者
Kuroda, Soichi [1 ]
Shinya, Akikazu [1 ,2 ]
Gomi, Harunori [1 ]
机构
[1] Nippon Dent Univ Tokyo, Dept Crown & Bridge, Sch Life Dent Tokyo, Chiyoda Ku, 1-9-20 Fujimi, Tokyo 1028158, Japan
[2] Univ Turku, Dept Prosthet Dent & Biomat Sci, Inst Dent, Lemminkaisenkatu 2, FIN-20520 Turku, Finland
关键词
CAD/CAM; Porcelain; Zirconia; Frame design; Fracture strength; LITHIUM DISILICATE CROWNS; FIXED DENTAL PROSTHESES; CERAMIC CROWNS; STRESS-DISTRIBUTION; SINGLE CROWNS; MARGINAL FIT; PART II; THICKNESS; RESISTANCE; TOUGHNESS;
D O I
10.4012/dmj.2017-218
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In this study, we investigated the effect of frame design on the fracture strength of a zirconia crown and porcelain-faced crown, with the aim of clinically applying a zirconia crown fabricated using computer-aided design and manufacturing. The results showed that the fracture strengths were 645.9 MPa with Frame Design 1, 759.5 MPa with Frame Design 2, and 989.7 MPa with Frame Design 3, suggesting that the fracture strength improved depending upon the frame design. The above information suggests that it is necessary for the zirconia crown frame form to have an occlusal surface table where the crown design has a reduced outer diameter, instead of using the conventional form of covering the abutment tooth with a thickness of 0.5 mm.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 31 条
[1]   Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners [J].
Abdel-Azim, Tamer ;
Rogers, Kelly ;
Elathamna, Eiad ;
Zandinejad, Amirali ;
Metz, Michael ;
Morton, Dean .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04) :554-559
[2]   3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions [J].
Anadioti, Evanthia ;
Aquilino, Steven A. ;
Gratton, David G. ;
Holloway, Julie A. ;
Denry, Isabelle ;
Thomas, Geb W. ;
Qian, Fang .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08) :610-617
[3]   Finite Element Analysis of the Influence of Geometry and Design of Zirconia Crowns on Stress Distribution [J].
Anami, Lilian Costa ;
da Costa Lima, Julia Magalhaes ;
Corazza, Pedro Henrique ;
Colauto Yamamoto, Eron Toshio ;
Bottino, Marco Antonio ;
Souto Borges, Alexandre Luiz .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (02) :146-151
[4]   Biaxial Flexure Strength and Low Temperature Degradation of Ce-TZP/Al2O3 Nanocomposite and Y-TZP as Dental Restoratives [J].
Ban, Seiji ;
Sato, Hideo ;
Suehiro, Yasuhiko ;
Nakanishi, Hideo ;
Nawa, Masahiro .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 87B (02) :492-498
[5]   Effect of framework design on crown failure [J].
Bonfante, Estevam A. ;
da Silva, Nelson R. F. A. ;
Coelho, Paulo G. ;
Bayardo-Gonzalez, Daniel E. ;
Thompson, Van P. ;
Bonfante, Gerson .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (02) :194-199
[6]   Aesthetic Functional Area Protection Concept for Prevention of Ceramic Chipping with Zirconia Frameworks [J].
Broseghini, Cristiano ;
Broseghini, Mauro ;
Gracis, Stefano ;
Vigolo, Paolo .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (02) :174-176
[7]   THE REHABILITATION OF AN EDENTULOUS MANDIBLE WITH A CAD/CAM ZIRCONIA FRAMEWORK AND HEAT-PRESSED LITHIUM DISILICATE CERAMIC CROWNS: A CLINICAL REPORT [J].
Cho, Youngwook ;
Raigrodski, Ariel J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (06) :443-447
[8]   STRESS DISTRIBUTION IN PORCELAIN-FUSED-TO-GOLD CROWNS AND PREPARATIONS CONSTRUCTED WITH PHOTOELASTIC PLASTICS [J].
CRAIG, RG ;
ELEBRASH.MK ;
PEYTON, FA .
JOURNAL OF DENTAL RESEARCH, 1971, 50 (05) :1278-&
[9]   Fracture resistance of three porcelain-layered CAD/CAM zirconia frame designs [J].
Ferrari, Marco ;
Giovannetti, Agostino ;
Carrabba, Michele ;
Bonadeo, Giovanni ;
Rengo, Carlo ;
Monticelli, Francesca ;
Vichi, Alessandro .
DENTAL MATERIALS, 2014, 30 (07) :E163-E168
[10]   Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics [J].
Guazzato, M ;
Albakry, M ;
Ringer, SP ;
Swain, MV .
DENTAL MATERIALS, 2004, 20 (05) :449-456