Optic disc dose reduction in ocular brachytherapy using 125I notched COMS plaques: A simulation study based on current clinical practice

被引:6
作者
Lee, Yongsook C. [1 ]
Lin, Shih-Chi [1 ]
Kim, Yongbok [1 ]
机构
[1] Univ Arizona, Dept Radiat Oncol, Tucson, AZ 85721 USA
关键词
I-125; Collaborative Ocular Melanoma Study (COMS); notched plaques; optic disc dose reduction; ocular brachytherapy; SLOTTED EYE PLAQUE; CHOROIDAL MELANOMA; RADIATION-THERAPY; JUXTAPAPILLARY; RADIOTHERAPY; OUTCOMES; AAPM;
D O I
10.1002/acm2.12966
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Although notched Collaborative Ocular Melanoma Study (COMS) plaques have been widely used, optic disc dose reduction by notched COMS plaques has not been discussed in the literature. Therefore, this study investigated optic disc dose reduction in ocular brachytherapy using(125)I notched COMS plaques in comparison with optic disc dose for(125)I standard COMS plaques. Methods For this simulation study, an in-house brachytherapy dose calculation program was developed using MATLAB software by incorporating the American Association of Physicists in Medicine Task Group-43 Update (AAPM TG-43U1) dosimetry formalism with a line source approximation in a homogeneous water medium and COMS seed coordinates in the AAPM TG 129. Using this program, optic disc doses for standard COMS plaques (from 12 to 22 mm in diameter in 2 mm increments) and notched COMS plaques with one seed removed (Case #1, from 12 to 22 mm) and with two seeds removed (Case #2, from 14 to 22 mm) were calculated as a function of tumor margin-to-optic disc distance (DT) for various tumor basal dimensions (BDs) for prescription depths from 1 to 10 mm in 1 mm intervals. A dose of 85 Gy for an irradiation time of 168 h was prescribed to each prescription depth. Then absolute and relative optic disc dose reduction by notched COMS plaques (Cases #1 and #2) was calculated for all prescription depths. Results Optic disc dose reduction by notched COMS plaques (Cases #1 and #2) had five unique trends related to maximum optic disc dose reduction and corresponding optimal DT for each BD in each plaque. It increased with increasing prescription depth. Conclusions The results presented in this study would enable the clinician to choose an adequate plaque type among standard and notched(125)I COMS plaques and a prescription depth to minimize optic disc dose.
引用
收藏
页码:57 / 70
页数:14
相关论文
共 17 条
[1]   Dosimetry of 125I and 103Pd COMS eye plaques for intraocular tumors: Report of Task Group 129 by the AAPM and ABS [J].
Chiu-Tsao, Sou-Tung ;
Astrahan, Melvin A. ;
Finger, Paul T. ;
Followill, David S. ;
Meigooni, Ali S. ;
Melhus, Christopher S. ;
Mourtada, Firas ;
Napolitano, Mary E. ;
Nath, Ravinder ;
Rivard, Mark J. ;
Rogers, D. W. O. ;
Thomson, Rowan M. .
MEDICAL PHYSICS, 2012, 39 (10) :6161-6184
[2]  
Diener-West M, 2001, ARCH OPHTHALMOL-CHIC, V119, P951
[3]   Finger's "slotted'' eye plaque for radiation therapy: treatment of juxtapapillary and circumpapillary intraocular tumours [J].
Finger, Paul T. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (07) :891-894
[4]   A Five-Year Study of Slotted Eye Plaque Radiation Therapy for Choroidal Melanoma: Near, Touching, or Surrounding the Optic Nerve [J].
Finger, Paul T. ;
Chin, Kimberly J. ;
Tena, Lawrence B. .
OPHTHALMOLOGY, 2012, 119 (02) :415-422
[5]   Juxtapapillary and circumpapillary choroidal melanoma: globe-sparing treatment outcomes with iodine-125 notched plaque brachytherapy [J].
Hegde, John V. ;
McCannel, Tara A. ;
McCannel, Colin A. ;
Lamb, James ;
Wang, Pin-Chieh ;
Veruttipong, Darlene ;
Almanzor, Robert ;
Demanes, D. Jeffrey ;
Kamrava, Mitchell .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (09) :1843-1850
[6]  
Kline R., Coordinate localization of eye plaque for Collaborative Ocular Melanoma Study
[7]   Dosimetric and Late Radiation Toxicity Comparison Between Iodine-125 Brachytherapy and Stereotactic Radiation Therapy for Juxtapapillary Choroidal Melanoma [J].
Krema, Hatem ;
Heydarian, Mostafa ;
Beiki-Ardakani, Akbar ;
Weisbrod, Daniel ;
Xu, Wei ;
Laperriere, Normand J. ;
Sahgal, Arjun .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03) :510-515
[8]   A practical approach to estimating optic disc dose and macula dose without treatment planning in ocular brachytherapy using 125I COMS plaques [J].
Lee, Yongsook C. ;
Lin, Shih-Chi ;
Kim, Yongbok .
RADIATION ONCOLOGY, 2018, 13
[9]   The American brachytherapy society recommendations for brachytherapy of uveal melanomas [J].
Nag, S ;
Quivey, JM ;
Earle, JD ;
Followill, D ;
Fontanesi, J ;
Finger, PT .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :544-555
[10]   Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations [J].
Rivard, MJ ;
Coursey, BM ;
DeWerd, LA ;
Hanson, WF ;
Huq, MS ;
Ibbott, GS ;
Mitch, MG ;
Nath, R ;
Williamson, JF .
MEDICAL PHYSICS, 2004, 31 (03) :633-674