Cardiac Troponin Assays: Guide to Understanding Analytical Characteristics and Their Impact on Clinical Care

被引:302
作者
Apple, Fred S. [1 ,2 ]
Sandoval, Yader [3 ,4 ]
Jaffe, Allan S. [5 ,6 ]
Ordonez-Llanos, Jordi [7 ,8 ]
机构
[1] Hennepin Cty Med Ctr, Dept Lab Med & Pathol, Minneapolis, MN 55415 USA
[2] Univ Minnesota, Minneapolis, MN USA
[3] Hennepin Cty Med Ctr, Dept Med, Div Cardiol, Minneapolis, MN 55415 USA
[4] Abbott NW Hosp, Minneapolis Heart Inst, Minneapolis, MN USA
[5] Mayo Clin, Rochester, MN USA
[6] Mayo Coll Med, Rochester, MN USA
[7] Hosp Santa Creu & Sant Pau, IBB, Serv Bioquim, Barcelona, Spain
[8] Univ Autonoma Barcelona, Dept Bioquim & Biol Mol, Barcelona, Spain
关键词
ACUTE MYOCARDIAL-INFARCTION; ACUTE CORONARY SYNDROME; HIGH-SENSITIVITY; 99TH PERCENTILE; CHEST-PAIN; I ASSAYS; SKELETAL-MUSCLE; DIAGNOSIS; STANDARDIZATION; RISK;
D O I
10.1373/clinchem.2016.255109
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Cardiac troponin I (cTnI) and cardiac troponin T (cTnT) determinations are fixtures in clinical practice and research. Cardiac troponin testing has been the standard of practice for the diagnosis of acute myocardial infarction (AMI), early rule-out, risk stratification, and outcomes assessment in patients presenting with acute coronary syndrome (ACS) and non -ACS myocardial injury. We recognize from reading the literature over the past several years how poorly understood the analytical characteristics are for cTnI and cTnT assays by laboratorians, clinicians, and scientists who use these assays. CONTENT: The purposes of this mini-review are (a) to define limit of blank, limit of detection, limit of quantification, and imprecision, (b) overview the analytical characteristics of the existing cardiac troponin assays, (c) recommend approaches to define a healthy (normal) reference population for determining the 99th percentile and the appropriate statistic to use for this calculation, (d) clarify how an assay becomes designated as "high sensitivity," and (e) provide guidance on determining delta (Delta) change values. SUMMARY: This review raises important educational information regarding-cTnI and cTnT assays, their 99th percentile upper reference limits (URL) differentiated by sex, and specifically addresses high-sensitivity (hs)-assays used to measure low concentrations. Recommendations are made to help clarify the nomenclature and analytical and clinical characteristics to define hs-assays. The review also identifies challenges for the evolving implementation of hs-assays into clinical practice. It is hoped that with the introduction of these concepts, laboratorians, clinicians and researchers can develop a more unified view of how these assays should be used worldwide. (c) 2016 American Association for Clinical Chemistry
引用
收藏
页码:73 / 81
页数:9
相关论文
共 39 条
[1]   Cardiac troponin assays: a review of quantitative point-of-care devices and their efficacy in the diagnosis of myocardial infarction [J].
Amundson, Beret E. ;
Apple, Fred S. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (05) :665-676
[2]  
[Anonymous], ANN EMERG MED
[3]  
[Anonymous], HEART METAB
[4]   IFCC educational materials on selected analytical and clinical applications of high sensitivity cardiac troponin assays [J].
Apple, Fred S. ;
Jaffe, Allan S. ;
Collinson, Paul ;
Mockel, Martin ;
Ordonez-Llanos, Jordi ;
Lindahl, Bertil ;
Hollander, Judd ;
Plebani, Mario ;
Than, Martin ;
Chan, M. H. M. .
CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) :201-203
[5]   Improving the 510(k) FDA Process for Cardiac Troponin Assays: In Search of Common Ground [J].
Apple, Fred S. ;
Hollander, Judd ;
Wu, Alan H. B. ;
Jaffe, Allan S. .
CLINICAL CHEMISTRY, 2014, 60 (10) :1273-1275
[6]   Clinical Implications of a Recent Adjustment to the High-Sensitivity Cardiac Troponin T Assay: User Beware [J].
Apple, Fred S. ;
Jaffe, Allan S. .
CLINICAL CHEMISTRY, 2012, 58 (11) :1599-1600
[7]   Determination of 19 Cardiac Troponin I and T Assay 99th Percentile Values from a Common Presumably Healthy Population [J].
Apple, Fred S. ;
Ler, Ranka ;
Murakami, MaryAnn M. .
CLINICAL CHEMISTRY, 2012, 58 (11) :1574-1581
[8]   Delta changes for optimizing clinical specificity and 60-day risk of adverse events in patients presenting with symptoms suggestive of acute coronary syndrome utilizing the ADVIA Centaur TnI-Ultra assay [J].
Apple, Fred S. ;
Smith, Stephen W. ;
Pearce, Lesly A. ;
Murakami, MaryAnn M. .
CLINICAL BIOCHEMISTRY, 2012, 45 (10-11) :711-713
[9]   Increased Cardiac Troponin I As Measured by a High-Sensitivity Assay Is Associated with High Odds of Cardiovascular Death: The Minnesota Heart Survey [J].
Apple, Fred S. ;
Steffen, Lyn M. ;
Pearce, Lesly A. ;
Murakami, MaryAnn M. ;
Luepker, Russell V. .
CLINICAL CHEMISTRY, 2012, 58 (05) :930-935
[10]   Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays [J].
Apple, Fred S. ;
Collinson, Paul O. .
CLINICAL CHEMISTRY, 2012, 58 (01) :54-61