Radiation Dose Reduction in Computed Tomography-Guided Lung Interventions using an Iterative Reconstruction Technique

被引:10
作者
Chang, D. H. [1 ]
Hiss, S. [1 ]
Mueller, D. [2 ]
Hellmich, M. [3 ]
Borggrefe, J. [1 ]
Bunck, A. C. [1 ]
Maintz, D. [1 ]
Hackenbroch, M. [1 ]
机构
[1] Univ Hosp Cologne, Dept Radiol, D-50924 Cologne, Germany
[2] Clin Sci Philips Healthcare GmbH, Clin Sci, Munich, Germany
[3] Univ Hosp Cologne, Inst Med Stat Informat & Epidemiol, D-50924 Cologne, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2015年 / 187卷 / 10期
关键词
thorax; biopsy; CT; interventional procedures; image manipulation/reconstruction; IMAGE QUALITY; NOISE-REDUCTION; MEDICAL STAFF; CT; EXPOSURE; BIOPSY; ACCURACY; PATIENT;
D O I
10.1055/s-0035-1553125
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the radiation doses and image qualities of computed tomography (CT)-guided interventions using a standard-dose CT (SDCT) protocol with filtered back projection and a low-dose CT (LDCT) protocol with both filtered back projection and iterative reconstruction. Materials and Methods: Image quality and radiation doses (dose-length product and CT dose index) were retrospectively reviewed for 130 patients who underwent CT-guided lung interventions. SDCT at 120 kVp and automatic mA modulation and LDCT at 100 kVp and a fixed exposure were each performed for 65 patients. Image quality was objectively evaluated as the contrast-to-noise ratio and subjectively by two radiologists for noise impression, sharpness, artifacts and diagnostic acceptability on a four-point scale. Results: The groups did not significantly differ in terms of diagnostic acceptability and complication rate. LDCT yielded a median 68.6 % reduction in the radiation dose relative to SDCT. In the LDCT group, iterative reconstruction was superior to filtered back projection in terms of noise reduction and subjective image quality. The groups did not differ in terms of beam hardening artifacts. Conclusion: LDCT was feasible for all procedures and yielded a more than two-thirds reduction in radiation exposure while maintaining overall diagnostic acceptability, safety and precision. The iterative reconstruction algorithm is preferable according to the objective and subjective image quality analyses.
引用
收藏
页码:906 / 914
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 96 AAPM
[2]   Evaluation of patient and staff doses during various CT fluoroscopy guided interventions [J].
Buls, N ;
Pagés, J ;
de Mey, J ;
Osteaux, M .
HEALTH PHYSICS, 2003, 85 (02) :165-173
[3]   FINGER DOSES IN SPECIAL PROCEDURES [J].
BURGESS, AE ;
BURHENNE, HJ .
BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (679) :650-651
[4]   Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study [J].
Haeusler, Uwe ;
Czarwinski, Renate ;
Brix, Gunnar .
EUROPEAN RADIOLOGY, 2009, 19 (08) :2000-2008
[5]   Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583
[6]   Detection of ground-glass opacities by use of hybrid iterative reconstruction (iDose) and low-dose 256-section computed tomography: A phantom study [J].
Higuchi K. ;
Nagao M. ;
Matsuo Y. ;
Sunami S. ;
Kamitani T. ;
Jinnouchi M. ;
Yonezawa M. ;
Yamasaki Y. ;
Yabuuchi H. ;
Hatkenaka M. ;
Honda H. .
Radiological Physics and Technology, 2013, 6 (2) :299-304
[7]   Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction [J].
Hosch, Waldemar ;
Stiller, Wolfram ;
Mueller, Dirk ;
Gitsioudis, Gitsios ;
Welzel, Johanna ;
Dadrich, Monika ;
Buss, Sebastian J. ;
Giannitsis, Evangelos ;
Kauczor, Hans U. ;
Katus, Hugo A. ;
Korosoglou, Grigorios .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) :3568-3576
[8]  
Inui N, 1998, Nihon Kokyuki Gakkai Zasshi, V36, P1038
[9]   Low-dose CT of the abdomen: Evaluation of image improvement with use of noise reduction filters - Pilot study [J].
Kalra, MK ;
Maher, MM ;
Sahani, DV ;
Blake, MA ;
Hahn, PF ;
Avinash, GB ;
Toth, TL ;
Halpern, E ;
Saini, S .
RADIOLOGY, 2003, 228 (01) :251-256
[10]   Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique [J].
Katsura, Masaki ;
Matsuda, Izuru ;
Akahane, Masaaki ;
Sato, Jiro ;
Akai, Hiroyuki ;
Yasaka, Koichiro ;
Kunimatsu, Akira ;
Ohtomo, Kuni .