摘要
A square-slot-loaded (SSL) radio-frequency (RF) resonator using a microstrip transmission line (MTL) is designed for human-body magnetic resonance imaging (MRI) at 3 T MRI. The SSL RF resonator shows improved RF magnetic fields resulting in more homogenous fields near the center of the phantom than traditional RF resonators using MTL. A multichannel body coil using the SSL RF resonators is also simulated and provides improved parallel excitation performance. In addition, RF shimming for homogenization can be effectively controlled by adjusting the inputs to the eight resonators. Numerical results are obtained by using a spherical phantom and a realistic human-body model at 3 T to calculate the B (1) (+) fields.
引用
收藏
页码:813 / 816
页数:4
相关论文
共 50 条
  • [1] A novel RF resonator for human-body MRI at 3 T
    Hyeok-Woo Son
    Young-Ki Cho
    Hyoungsuk Yoo
    Journal of the Korean Physical Society, 2014, 64 : 813 - 816
  • [2] A novel RF resonator using microstrip transmission line for human body MRI at 3T
    Son, Hyeok-Woo
    Cho, Young-Ki
    Yoo, Hyungsuk
    2013 PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), VOLS 1 AND 2, 2013,
  • [3] Design of a loop resonator with a split-ring-resonator (SRR) for a human-body coil in 3 T MRI systems
    Son, Hyeok Woo
    Cho, Young Ki
    Kim, Byung Mun
    Back, Hyun Man
    Yoo, Hyoungsuk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 68 (07) : 908 - 913
  • [4] Design of a loop resonator with a split-ring-resonator (SRR) for a human-body coil in 3 T MRI systems
    Hyeok Woo Son
    Young Ki Cho
    Byung Mun Kim
    Hyun Man Back
    Hyoungsuk Yoo
    Journal of the Korean Physical Society, 2016, 68 : 908 - 913
  • [5] USE OF A HUMAN-BODY SIMULATOR FOR ANALYSIS OF MRI ANTENNAS
    OCHI, H
    YAMAMOTO, E
    SAWAYA, K
    ADACHI, S
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS, 1994, 77 (01): : 77 - 84
  • [6] SOCIAL ASPECTS OF THE HUMAN-BODY - POLHEMUS,T
    JURGENS, HW
    HOMO-JOURNAL OF COMPARATIVE HUMAN BIOLOGY, 1982, 33 (01) : 63 - 63
  • [7] SOCIAL ASPECTS OF HUMAN-BODY - POLHEMUS,T
    CARTER, A
    NEW SOCIETY, 1978, 44 (820): : 671 - 672
  • [8] THE BODY READER - SOCIAL ASPECTS OF THE HUMAN-BODY - POLHEMUS,T
    LYNCH, B
    JOURNAL OF COMMUNICATION, 1980, 30 (02) : 224 - 226
  • [9] 3-DIMENSIONAL RECONSTRUCTION OF THE HUMAN-BODY
    FISHMAN, EK
    DREBIN, RA
    HRUBAN, RH
    NEY, DR
    MAGID, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) : 1419 - 1420
  • [10] TERRITORIES AND THE HUMAN-BODY
    JAVEAU, C
    DONNER, F
    REVUE DE L INSTITUT DE SOCIOLOGIE, 1984, (3-4): : 657 - 671