Standardization of volumetric modulated arc therapy-based frameless stereotactic technique using a multidimensional ensemble-aided knowledge-based planning

被引:9
|
作者
Sarkar, Biplab [1 ]
Munshi, Anusheel [1 ]
Ganesh, Tharmarnadar [1 ]
Manikandan, Arjunan [2 ]
Anbazhagan, Satheesh Kumar [1 ]
Mohanti, Bidhu Kalyan [1 ]
机构
[1] Fortis Mem Res Inst, Dept Radiat Oncol, Gurgaon, Haryana, India
[2] Nagarjuna Hosp, Vijayawada 520007, Andhra Pradesh, India
关键词
ensemble mapping; KBP; knowledge-based planning; SRS; SRT; VMAT; RADIATION-THERAPY; PRECLINICAL VALIDATION; BRAIN-TUMORS; AT-RISK; RADIOSURGERY; RADIOTHERAPY; QUALITY; HEAD; OPTIMIZATION; PREDICTION;
D O I
10.1002/mp.13470
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Aim of this article is to describe a new knowledge-based planning (KBP) methodology using volumetric modulated arc therapy (VMAT) for stereotactic radiosurgery (SRS) and radiotherapy (SRT) assisted by an ensemble mapping technique for use in a Monte Carlo planning system. Methods Libraries of 121 stereotactic patients were assembled on the basis of eight different parameters (a) tumor laterality, (b) whether planning target volume (PTV) dose coverage challenged by the presence of the organ at risk (OAR), (c) prescription dose and number of fractions, (d) number of PTVs, (e) tumor volume, (f) shortest distance between OAR and PTV (edge to edge distance, or EED), (g) center to center distance between OARs and PTV (CCD), and (h) lateral dimension of external contour (brain). For new patients, the most appropriate library plan was selected on the basis of the above categorization. A KBP plan was created based on this selected library plan with all parameters unchanged keeping the isocenter at the center of PTV. Using the same beam configuration, another independent treatment plan (IP) was generated by an experienced dosimetrist for comparison. IP and KBP were compared for 76 new patients. Results Of 197 patients (121 library and 76 new), 103 (52.3%) were placed in the OAR-challenged category and 94 were placed in the OAR unchallenged category. The ensemble mapping technique shows that, for an OAR-challenged patient, picking up the library plan is appropriate. IP was marginally better than KBP in PTV coverage and dose conformity (PCI). Library plans, IP, and KBP offer a mean PCI of 0.77 +/- 0.2, 0.79 +/- 0.2, and 0.78 +/- 0.4, mean PTV-V99% of 97.3 +/- 22.0%, 98.9 +/- 14.1%, and 98.2 +/- 13.2%, and mean MU of 2403.8 +/- 2403.8, 2344.0 +/- 2423.6, and 2473.6 +/- 2296.8, respectively. Statistically significant differences were observed in the planning time between the IP and KBP plans for both OAR-challenged (P < 0.001) and -unchallenged (P < 0.002) categories. Comparison of optimization and dose calculation time showed a much lower average planning time of 111.0 +/- 84.1 min for KBP as against 248.2 +/- 96.6 min for IP. Conclusion Validation results for KBP plans indicate the multidimensional ensemble mapping mechanism can accurately pick up the most appropriate library plan. KBP plans, although slightly inferior in their dosimetric quality, fulfill all the required clinical conditions and dose constraints. KBP plans save considerable planning time and are nearly independent of the skill and knowledge of the treatment planner. KBP works well with a Monte Carlo planning system like Monaco.
引用
收藏
页码:1953 / 1962
页数:10
相关论文
共 50 条
  • [1] Evaluation of a highly refined prediction model in knowledge-based volumetric modulated arc therapy planning for cervical cancer
    Wang, Mingli
    Gu, Huikuan
    Hu, Jiang
    Liang, Jian
    Xu, Sisi
    Qi, Zhenyu
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [2] Knowledge-based volumetric modulated arc therapy treatment planning for breast cancer
    Apaza Blanco, Oscar
    Almada, Maria
    Garcia Andino, Albin
    Zunino, Silvia
    Venencia, Daniel
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (04) : 334 - 340
  • [3] Dosimetry and efficiency comparison of knowledge-based and manual planning using volumetric modulated arc therapy for craniospinal irradiation
    Tsai, Wei-Ta
    Hsieh, Hui-Ling
    Hung, Shih-Kai
    Zeng, Chi-Fu
    Lee, Ming-Fen
    Lin, Po-Hao
    Lin, Chia-Yi
    Li, Wei-Chih
    Chiou, Wen-Yen
    Wu, Tung-Hsin
    RADIOLOGY AND ONCOLOGY, 2024, 58 (02) : 289 - 299
  • [4] Knowledge-based planning using pseudo-structures for volumetric modulated arc therapy (VMAT) of postoperative uterine cervical cancer: a multi-institutional study
    Kamima, Tatsuya
    Ueda, Yoshihiro
    Fukunaga, Jun-ichi
    Tamura, Mikoto
    Shimizu, Yumiko
    Muraki, Yuta
    Yoshioka, Yasuo
    Kitamura, Nozomi
    Nitta, Yuya
    Otsuka, Masakazu
    Monzen, Hajime
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (06) : 849 - 860
  • [5] Standardization of knowledge-based volumetric modulated arc therapy planning with a multi-institution model (broad model) to improve prostate cancer treatment quality
    Ueda, Yoshihiro
    Fukunaga, Jun-ichi
    Kamima, Tatsuya
    Shimizu, Yumiko
    Kubo, Kazuki
    Doi, Hiroshi
    Monzen, Hajime
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (03) : 1091 - 1100
  • [6] Characterization of knowledge-based volumetric modulated arc therapy plans created by three different institutions' models for prostate cancer
    Ueda, Yoshihiro
    Monzen, Hajime
    Fukunaga, Jun-ichi
    Ohira, Shingo
    Tamura, Mikoto
    Suzuki, Osamu
    Inui, Shoki
    Isono, Masaru
    Miyazaki, Masayoshi
    Sumida, Iori
    Ogawa, Kazuhiko
    Teshima, Teruki
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (06) : 1023 - 1028
  • [7] Development and clinical implementation of a simple knowledge-based planning tool for prostate volumetric modulated arc therapy
    Wilson, Mark Lee
    Harding, Nicholas Oliver
    Colley, William Peter
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (06):
  • [8] Dosimetric evaluation with knowledge-based planning created at different periods in volumetric-modulated arc therapy for prostate cancer: a multi-institution study
    Monzen, Hajime
    Tamura, Mikoto
    Ueda, Yoshihiro
    Fukunaga, Jun-ichi
    Kamima, Tatsuya
    Muraki, Yuta
    Kubo, Kazuki
    Nakamatsu, Kiyoshi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (04) : 327 - 335
  • [9] Dose-volume Histogram Analysis of Knowledge-based Volumetric-modulated Arc Therapy Planning in Postoperative Breast Cancer Irradiation
    Inoue, Eri
    Doi, Hiroshi
    Monzen, Hajime
    Tamura, Mikoto
    Inada, Masahiro
    Ishikawa, Kazuki
    Nakamatsu, Kiyoshi
    Nishimura, Yasumasa
    IN VIVO, 2020, 34 (03): : 1095 - 1101
  • [10] An updating approach for knowledge-based planning models to improve plan quality and variability in volumetric-modulated arc therapy for prostate cancer
    Nakamura, Kenji
    Okuhata, Katsuya
    Tamura, Mikoto
    Otsuka, Masakazu
    Kubo, Kazuki
    Ueda, Yoshihiro
    Nakamura, Yasunori
    Nakamatsu, Kiyoshi
    Tanooka, Masao
    Monzen, Hajime
    Nishimura, Yasumasa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 113 - 122