The accuracy of Goldmann applanation tonometry over silicone hydrogel contact lenses in patients with glaucoma

被引:4
作者
Gomes, Beatriz A. F. [1 ,2 ]
Turiel, Paulo [2 ]
Cavalcanti, Rachel S. [2 ]
Moraes, Haroldo V., Jr. [1 ]
Santhiago, Marcony R. [1 ,3 ]
机构
[1] Univ Fed Rio de Janeiro, BR-22775040 Rio De Janeiro, RJ, Brazil
[2] Fed Hosp Bonsucesso, Rio De Janeiro, RJ, Brazil
[3] Univ Sao Paulo, Sao Paulo, Brazil
关键词
Intraocular pressure; Tonometry; Contact lens; Glaucoma; INTRAOCULAR-PRESSURE; AGREEMENT;
D O I
10.1016/j.clae.2014.04.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the accuracy of measuring intraocular pressure over a silicone hydrogel contact lens using Goldmann applanation tonometry in eyes with glaucoma. Methods: This was a prospective, randomized study and enrolled 28 patients (28 right eyes) with primary open angle glaucoma. Intraocular pressure was taken with and without a silicone hydrogel contact lens (-0.50 D), in situ (using Goldmann applanation tonometry), in a randomized order of measurements. Statistical analysis was performed using paired t-test and Bland-Altman plot. Results: The mean difference (+/- standard deviation) found between intraocular pressure measurement without (mean 16.7 +/- 3.2 mmHg) and with (mean 17.3 +/- 3.0 mmHg) contact lens was found to be -0.57 +/- 2.3 mmHg (95% confidence interval, -1.5 to 0.3). No significant statistical difference was found between the two groups with paired t-test (p = 0.19). The Bland Altman plot showed some evidence of increasing variability of differences between two measures of intraocular pressure, with increasing intraocular pressure. The 95% limits of agreement of the Bland Altman plot were unacceptably large (-5 mmHg to 3.9 mmHg). Conclusion: Agreement between Goldmann applanation tonometry with and without contact lenses seems to be poor in patients with glaucoma, especially for high intraocular pressure. (C) 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:297 / 299
页数:3
相关论文
共 23 条
  • [1] Allen R J, 2007, Cont Lens Anterior Eye, V30, P267, DOI 10.1016/j.clae.2007.02.008
  • [2] Arora Ritu, 2004, Cont Lens Anterior Eye, V27, P39, DOI 10.1016/j.clae.2003.09.004
  • [3] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Correlation, Agreement, and Bland-Altman Analysis: Statistical Analysis of Method Comparison Studies
    Bunce, Catey
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (01) : 4 - 6
  • [7] The influence of soft contact lenses on the intraocular pressure measurement
    Firat, P. G.
    Cankaya, C.
    Doganay, S.
    Cavdar, M.
    Duman, S.
    Ozsoy, E.
    Koc, B.
    [J]. EYE, 2012, 26 (02) : 278 - 282
  • [8] The Accuracy of Dynamic Contour Tonometry Over Soft Contact Lenses
    Gogniat, Fabrice
    Steinegger, Daniela
    Nosch, Daniela S.
    Joos, Roland
    Goldschmidt, Michael
    [J]. OPTOMETRY AND VISION SCIENCE, 2013, 90 (02) : 125 - 130
  • [9] TONO-PEN ESTIMATION OF INTRAOCULAR-PRESSURE THROUGH BANDAGE CONTACT-LENSES
    KHAN, JA
    LAGRECA, BA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (04) : 422 - 425
  • [10] Kreda S H, 1987, J Am Optom Assoc, V58, P208