Minimally invasive assessment of hepatic function in children with indocyanine green elimination: a validation study
被引:5
作者:
Nielsen, Jon
[1
]
Nerup, Nikolaj
[2
]
Moller, Soren
[3
,4
]
de Nijs, Robin
[5
]
Rasmussen, Allan
[2
]
Svendsen, Lars Bo
[2
]
Kjaer, Mette Skalshoi
[6
]
Christensen, Vibeke Brix
[1
]
Borgwardt, Lise
[5
]
机构:
[1] Copenhagen Univ Hosp, Rigshosp, Dept Paediat & Adolescent Med, Blegdamsvej 9, DK-2100 Copenhagen O, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Surg Gastroenterol & Transplantat, Copenhagen O, Denmark
[3] Hvidovre Univ Hosp, Fac Hlth Sci, Ctr Funct Imaging & Res, Dept Clin Physiol, Hvidovre, Denmark
[4] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
[5] Copenhagen Univ Hosp, Rigshosp, Dept Clin Physiol Nucl Med & PET, Copenhagen O, Denmark
[6] Copenhagen Univ Hosp, Rigshosp, Dept Med Gastroenterol & Hepatol, Copenhagen O, Denmark
关键词:
Pediatric liver disease;
biliary atresia;
autoimmune hepatitis;
liver transplantation;
indocyanine green;
liver function tests;
PLASMA DISAPPEARANCE RATE;
ACUTE LIVER-FAILURE;
RETENTION TEST;
PORTAL-HYPERTENSION;
DISEASE;
HEPATECTOMY;
CLEARANCE;
CIRRHOSIS;
LIMON;
SCORE;
D O I:
10.1080/00365521.2019.1591497
中图分类号:
R57 [消化系及腹部疾病];
学科分类号:
摘要:
Objectives: Pediatric liver disease (PLD) covers a variety of etiologies and severities, from mild temporary illness to diseases with fatal outcomes. There is a demand for minimally invasive and reliable measures for assessment of the severity of PLD. Indocyanine green (ICG) elimination kinetics to estimate hepatic function has been used in adults for decades, however, due to invasiveness, the use in PLD is still limited. The aim of the present study was to evaluate minimally invasive estimation of ICG elimination by pulse spectrophotometry (ICGLi), in comparison with traditional spectrophotometry using serial blood samples (ICGbs).Methods: One hundred children aged 0-18 years were included in the study. ICG elimination kinetics was measured with ICGLi and ICGbs, and results compared by failure rates, mean difference, limits of agreement, Bland Altman plots and linear regression analysis. Plasma disappearance rates (PDRLi and PDRbs) were used for comparison.Results: One hundred and twelve simultaneous measurements in 87 patients were performed successfully. Mean difference for PDR (%/min) was 3.58 (95% CI 2.69; 4.47). Limits of agreement were -5.06; 12.22. A linear correlation between the two methods with a regression coefficient of 0.83 (SE 0.02 95% CI 0.80; 0.87) was found. For conversion we computed the following equation; PDRbs = 0.83xPDRLi.Conclusions: The present study shows that ICG PDR can be obtained by a minimally invasive method and thus replace measures by serial blood samples in children with liver disease of different etiologies and severities. However, a systematic relative difference between the two methods exists. Our proposed correction factor needs to be validated in larger cohorts.
引用
收藏
页码:485 / 491
页数:7